Fixation techniques and stem dimensions in hinged total knee arthroplasty: a finite element study

被引:0
作者
Bilal Farouk El-Zayat
Thomas J. Heyse
Nelson Fanciullacci
Luc Labey
Susanne Fuchs-Winkelmann
Bernardo Innocenti
机构
[1] University Hospital Marburg,Center of Orthopaedics and Traumatology
[2] University of Florence,Department of Mechanics and Industrial Technology
[3] KU Leuven,Mechanical Engineering Technology TC
[4] Université Libre de Bruxelles,BEAMS Department (Bio Electro and Mechanical Systems)
来源
Archives of Orthopaedic and Trauma Surgery | 2016年 / 136卷
关键词
Stem length; Hinged total knee arthroplasty; Finite element model; Cemented; Press fit;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1741 / 1752
页数:11
相关论文
共 50 条
  • [21] BIOMECHANICAL STUDY OF CERVICAL DISC ARTHROPLASTY DEVICES USING FINITE ELEMENT MODELS
    Purushothaman, Yuvaraj
    Choi, Hoon
    Yoganandan, Narayan
    Baisden, Jamie
    Rajasekaran, Deepak
    Jebaseelan, Davidson
    PROCEEDINGS OF THE ASME 2020 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2020, VOL 5, 2020,
  • [22] Posterior cruciate ligament balancing in total knee arthroplasty: a numerical study with a dynamic force controlled knee model
    Steinbruk, Arnd
    Woiczinski, Matthias
    Weber, Patrick
    Mueller, Peter Ernst
    Jansson, Volkmar
    Schroder, Christian
    BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [23] Posterior cruciate ligament balancing in total knee arthroplasty: a numerical study with a dynamic force controlled knee model
    Arnd Steinbrück
    Matthias Woiczinski
    Patrick Weber
    Peter Ernst Müller
    Volkmar Jansson
    Christian Schröder
    BioMedical Engineering OnLine, 13
  • [24] Mechanical Stress in Lumbar Total Disk Prostheses - A Finite Element Study
    Rotaru, Iuliana
    Munteanu, Florin
    Olaru, Dumitru
    2011 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2011,
  • [25] Consequences of partial and total plantar fascia release: A finite element study
    Cheung, JTM
    An, KN
    Zhang, M
    FOOT & ANKLE INTERNATIONAL, 2006, 27 (02) : 125 - 132
  • [26] A novel radiological index uses the inner canal diameter and the Citak classification index to predict risk factor for aseptic loosening following hinged total knee arthroplasty
    Ekhtiari, Seper
    Worthy, Tanis
    Rubinger, Luc
    Valdivielso, Ainhoa Alvarez
    Puri, Laura
    de Beer, Justin
    Citak, Mustafa
    Wood, Thomas J.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (09) : 4385 - 4390
  • [27] A Comparison Study of Four Cervical Disk Arthroplasty Devices Using Finite Element Models
    Purushothaman, Yuvaraj
    Choi, Hoon
    Yoganandan, Narayan
    Jebaseelan, Davidson
    Baisden, Jamie
    Kurpad, Shekar
    ASIAN SPINE JOURNAL, 2021, 15 (03) : 283 - 293
  • [28] Explicit Non-linear Finite Element Analysis for Prediction of Primary Stability in Uncemented Total Hip Arthroplasty
    Ovesy, Marzieh
    Zysset, Philippe K.
    COMPUTER METHODS, IMAGING AND VISUALIZATION IN BIOMECHANICS AND BIOMEDICAL ENGINEERING II, 2023, 38 : 128 - 142
  • [29] A three-dimensional finite element model of a human knee joint - A preliminary study
    Tan, S. H. N.
    Li, J. Z.
    Cheong, C. H.
    Lee, P. V. S.
    PROCEEDINGS OF THE FIFTH IASTED INTERNATIONAL CONFERENCE ON BIOMECHANICS, 2007, : 131 - 134
  • [30] The assessment of implant shape-dependent failure mechanisms in primary total hip arthroplasty using finite element analysis
    Kazemirad, Siavash
    Yazdi, Mohammad Ali
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2025, 28 (06) : 750 - 763