Indirect flow-injection determination of ascorbic acid by flame atomic absorption spectrometry

被引:0
|
作者
M del Carmen Yebra-Biurrun
Rosa Maria Cespón-Romero
Pilar Bermejo-Barrera
机构
[1] University of Santiago,Department of Analytical Chemistry, Nutrition and Bromatology, Chemistry Faculty
来源
Microchimica Acta | 1997年 / 126卷
关键词
flame atomic absorption spectrometry; flow injection; amberlite XAD-4; ascorbic acid;
D O I
暂无
中图分类号
学科分类号
摘要
A continuous-flow procedure is proposed for the indirect determination of ascorbic acid, based on its reducing properties because of the oxidation of its 1,2-enediol group. Iron(III) was injected into a 1,10-phenanthroline stream, which was mixed with a sample carrier and then with a sodium picrate solution stream. In these conditions the iron(III) was reduced to iron(II) by the ascorbic acid. Thus, the iron(II) formed reacts with 1,10-phenanthroline to form a charged red complex, which with picrate ion forms a stable red-orange uncharged ion-association complex that is adsorbed “on-line” on a non-ionic polymeric adsorbent (Amberlite XAD-4), proportionally to the ascorbic acid in the sample. The unadsorbed iron was determined by flame atomic absorption spectrometry. The proposed method allows the determination of ascorbic acid in the range 0.5–25 μg ml−1 with a relative standard deviation of 2.9% at a rate of ca. 90 samples h−1. This method has been applied to the determination of ascorbic acid in pharmaceutical preparations, fruit juices and sweets. The results obtained in the analysis are compared with those provided by the 2,6-dichloroindophenol method.
引用
收藏
页码:53 / 58
页数:5
相关论文
共 50 条
  • [21] DETERMINATION OF MERCURY IN URINE BY FLOW-INJECTION COLD VAPOR ATOMIC-ABSORPTION SPECTROMETRY
    GUO, TZ
    BAASNER, J
    ANALYTICA CHIMICA ACTA, 1993, 278 (01) : 189 - 196
  • [22] DETERMINATION OF ASCORBIC-ACID IN PHARMACEUTICALS AND URINE BY REVERSE FLOW-INJECTION
    ALBERO, MI
    GARCIA, MS
    SANCHEZPEDRENO, C
    RODRIGUEZ, J
    ANALYST, 1992, 117 (10) : 1635 - 1638
  • [23] ONLINE PRECONCENTRATION AND DETERMINATION OF TRACE PLATINUM BY FLOW-INJECTION ATOMIC-ABSORPTION SPECTROMETRY
    CANTARERO, A
    GOMEZ, MM
    CAMARA, C
    PALACIOS, MA
    ANALYTICA CHIMICA ACTA, 1994, 296 (02) : 205 - 211
  • [24] Determination of tin in pure copper by flow-injection hydride generation atomic absorption spectrometry
    Zhong, YS
    Lin, SJ
    Chen, SY
    Tsai, SJJ
    SPECTROSCOPY LETTERS, 2005, 38 (02) : 195 - 208
  • [25] DETERMINATION OF CADMIUM, COPPER AND LEAD IN ENVIRONMENTAL-SAMPLES - AN EVALUATION OF FLOW-INJECTION ONLINE SORBENT EXTRACTION FOR FLAME ATOMIC-ABSORPTION SPECTROMETRY
    MA, RL
    VANMOL, W
    ADAMS, F
    ANALYTICA CHIMICA ACTA, 1994, 285 (1-2) : 33 - 43
  • [26] Minicolumn field preconcentration and flow-injection flame atomic absorption spectrometric determination of cadmium in seawater
    Yebra-Biurrun, MC
    Moreno-Cid, A
    Puig, L
    ANALYTICA CHIMICA ACTA, 2004, 524 (1-2) : 73 - 77
  • [27] Flow-Injection Amperometric Method for Indirect Determination of Dopamine in the Presence of a Large Excess of Ascorbic Acid
    Gimenes, Denise Tofanello
    Pio dos Santos, Wallans Torres
    Tormin, Thiago Faria
    Abarza Munoz, Rodrigo Alejandro
    Richter, Eduardo Mathias
    ELECTROANALYSIS, 2010, 22 (01) : 74 - 78
  • [28] FLOW-INJECTION FLAME ATOMIC-ABSORPTION SPECTROMETRY FOR SLURRY ATOMIZATION - DETERMINATION OF CALCIUM, MAGNESIUM, IRON, ZINC AND MANGANESE IN VEGETABLES
    VINAS, P
    CAMPILLO, N
    GARCIA, IL
    CORDOBA, MH
    ANALYTICA CHIMICA ACTA, 1993, 283 (01) : 393 - 400
  • [29] Determination of copper in industrial water by innovative flow injection flame atomic absorption spectrometry
    Saxena, Reena
    Meena, Prem Lata
    Tiwari, Shelja
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2016, 44 (02) : 210 - 222
  • [30] DETERMINATION OF ASCORBIC-ACID BY FLOW-INJECTION WITH CHEMILUMINESCENCE DETECTION
    ALWARTHAN, AA
    ANALYST, 1993, 118 (06) : 639 - 642