Experimental evaluation of energy efficiency and velocity fields on a low-pressure axial flow fan (desktop type)

被引:0
作者
Robson L. Silva
Silvio X. Brito
机构
[1] Grande Dourados Federal University,College of Engineering
来源
Energy Efficiency | 2019年 / 12卷
关键词
Turbomachinery; Fan performance; Energy conversion; Flow measurements; Experimental techniques; Labeling program;
D O I
暂无
中图分类号
学科分类号
摘要
Energy efficiency labeling programs are worldwide applied to provide energy savings (electrical, mechanical, thermal, etc.) in machines and equipment for residential and industrial use, and also a potential reduction in greenhouse gas emissions. Actual research and development indicate that low-pressure axial flow fans represent a significant amount of energy consumption (electricity) especially in developing countries with warm climates, as in Brazil. In this work, bench tests were performed at university facilities, taking into account Brazilian standards for energy efficiency (Brazilian Labeling Program) for residential fans. Equipment under test is a free blow fan (desktop type, residential use), three-bladed with 500 mm diameter and angular speed ranging from ~ 500 up to 1500 s−1. Experimental analysis and measurement employed hot-wire anemometry, tachometer, wattmeter, chronometer, and data acquisition system. The results are for performance evaluation of turbomachinery characteristic curves. It includes airflow (m3 s−1), angular speed (s−1), the power supplied/received (W), efficacy ηENCE,n [(m3 s−1 W) m], and non-dimensional parameters: efficiency η (%) and design flow rate, as well as velocity field, among others. Main contributions indicate that (a) velocity and airflow in turbulent and fully developed conditions are consistent with energy efficiency and efficacy literature comparison, (b) power received by the fluid flow increases ten times more than supplied electrical energy (17/1.8), in the test range, (c) maximum energy conversion efficiency is ηmáx ~ 33% at ~ 1300 RPM and nominal flow rate φ ~ 0.165, (d) efficacy is lower than 0.0030 {[(m3 s−1) W)] m}, classified in “D” level, and (e) expected energy savings ~ 30% by reaching “A” efficacy levels.
引用
收藏
页码:697 / 710
页数:13
相关论文
共 34 条
[1]  
Downie RJ(1993)An engineering approach to blade designs for low to medium pressure rise rotor-only axial fans Experimental Thermal and Fluid Science 6 376-401
[2]  
Thompson MC(2010)Experimental and numerical study of the sweep effect on three-dimensional flow downstream of axial flow fans Flow Measurement and Instrumentation 21 155-165
[3]  
Wallis RA(2008)Experimental research for performance and noise of small axial flow fan Journal of Environmental Engineering 3 192-203
[4]  
Hurault J(2009)Experimental research for performance and noise of small axial fan International Journal of Fluid Machinery and Systems 2 136-146
[5]  
Kouidri S(2013)Experimental investigation of unsteady flow in axial skewed fans according to flow rates Experimental Thermal and Fluid Science 48 81-96
[6]  
Bakir F(2011)Experimental study of blade thickness effects on the overall and local performances of a controlled vortex designed axial-flow fan Experimental Thermal and Fluid Science 35 684-693
[7]  
Rey R(2015)Efficiency improvement opportunities for ceiling fans Energy Efficiency 8 37-50
[8]  
Ito T(1998)Three-dimensional flow in axial flow fans of non-free vortex design International Journal of Heat and Fluid Flow 19 601-607
[9]  
Minorikawa G(2008)Internal flow mechanism and experimental research of low pressure axial fan with forward-skewed blades Journal of Hydrodynamics, Series B 20 299-305
[10]  
Nagamatsu A(2007)Experimental research on aerodynamic performance and exit flow field of low pressure axial flow fan with circumferential skewed blades Journal of Hydrodynamics, Series B 19 579-586