Design parameters optimization of an electrothermal flow biosensor for the SARS-CoV-2 S protein immunoassay

被引:0
作者
Sameh Kaziz
Ibrahim Ben Mariem
Fraj Echouchene
Mohamed Hichem Gazzah
Hafedh Belmabrouk
机构
[1] University of Monastir,Quantum and Statistical Physics Laboratory, Faculty of Sciences of Monastir
[2] University of Tunis,Higher National Engineering School of Tunis, Taha Hussein Montfleury Boulevard
[3] University of Monastir,Laboratory of Electronics and Microelectronics, Faculty of Science of Monastir
[4] Majmaah University,Department of Physics, College of Science at Al Zulfi
来源
Indian Journal of Physics | 2022年 / 96卷
关键词
Biosensor; SARS-CoV-2 S protein; ACET flow; Design parameters; Detection time;
D O I
暂无
中图分类号
学科分类号
摘要
To combat the coronavirus disease 2019 (COVID-19), great efforts have been made by scientists around the world to improve the performance of detection devices so that they can efficiently and quickly detect the virus responsible for this disease. In this context we performed 2D finite element simulation on the kinetics of SARS-CoV-2 S protein binding reaction of a biosensor using the alternating current electrothermal (ACET) effect. The ACET flow can produce vortex patterns, thereby improving the transportation of the target analyte to the binding surface and thus enhancing the performance of the biosensor. Optimization of some design parameters concerning the microchannel height and the reaction surface, such as its length as well as its position on the top wall of the microchannel, in order to improve the biosensor efficiency, was studied. The results revealed that the detection time can be improved by 55% with an applied voltage of 10 Vrms and an operating frequency of 150 kHz and that the decrease in the height of the microchannel and in the length of the binding surface can lead to an increase in the rate of the binding reaction and therefore decrease the biosensor response time. Also, moving the sensitive surface from an optimal position, located in front of the electrodes, decreases the performance of the device.
引用
收藏
页码:4091 / 4101
页数:10
相关论文
共 50 条
  • [31] The adsorption effect on chemical kinetics at the reaction surface in a microfluidic channel of a biosensor for the SARS-Cov-2 detection
    Saad, Yosra
    Bouzid, Mohamed
    Selmi, Marwa
    Gazzah, Mohamed Hichem
    Almansour, Ahmed Mansour
    Boshra, Amira Yahia
    Mansouri, Sofiene Mohamed Habib
    Belmabrouk, Hafedh
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 369
  • [32] A performance comparison of heterostructure surface plasmon resonance biosensor for the diagnosis of novel coronavirus SARS-CoV-2
    Tarik Bin Abdul Akib
    Shahriar Mostufa
    Md. Masud Rana
    Md. Biplob Hossain
    Md. Rabiul Islam
    Optical and Quantum Electronics, 2023, 55 (5)
  • [33] A performance comparison of heterostructure surface plasmon resonance biosensor for the diagnosis of novel coronavirus SARS-CoV-2
    Akib, Tarik Bin Abdul
    Mostufa, Shahriar
    Rana, Md. Masud
    Hossain, Md. Biplob
    Islam, Md. Rabiul
    OPTICAL AND QUANTUM ELECTRONICS, 2023, 55 (05)
  • [34] MicroRNA of N-region from SARS-CoV-2: Potential sensing components for biosensor development
    Halim, Fatin Syakirah
    Parmin, N. A.
    Hashim, Uda
    Gopinath, Subash C. B.
    Dahalan, Farrah Aini
    Zakaria, Iffah Izzati
    Ang, Wei Chern
    Jaapar, Nurfareezah Fareezah
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2022, 69 (04) : 1696 - 1711
  • [35] Fabricating periodic sandwich SERS structure in detecting SARS-CoV-2 S protein with high-performance
    Liu, Yansheng
    Hu, Haonan
    Jia, Xiaobo
    Zhou, Jin
    Li, Hongli
    Wang, Xiaohong
    Zhang, Shaohui
    Chang, Haixin
    Li, Fuchong
    Wang, Guofu
    MICROCHEMICAL JOURNAL, 2024, 201
  • [36] Boron doped diamond thin films for the electrochemical detection of SARS-CoV-2 S1 protein
    Witt, Suzanne
    Rogien, Alexis
    Werner, Diana
    Siegenthaler, James
    Lesiyon, Raymond
    Kurien, Noelle
    Rechenberg, Robert
    Baule, Nina
    Hardy, Aaron
    Becker, Michael
    DIAMOND AND RELATED MATERIALS, 2021, 118
  • [37] Development of nucleic acid based lateral flow assays for SARS-CoV-2 detection
    Derin, Dilek Cam
    Gultekin, Enes
    Taskin, Irmak Icen
    Yakupogullari, Yusuf
    JOURNAL OF BIOSCIENCE AND BIOENGINEERING, 2023, 135 (02) : 87 - 92
  • [38] Optical biosensor based on a photonic crystal with a defective layer designed to determine the concentration of SARS-CoV-2 in water
    Efimov, I. M.
    Vanyushkin, N. A.
    Gevorgyan, A. H.
    Golik, S. S.
    PHYSICA SCRIPTA, 2022, 97 (05)
  • [39] Great enhancement of sensitivity for SARS-CoV-2 detection by integrated graphene FET biosensor using ζ potential modulator
    Yamamoto, Kaori
    Sato, Natsuki
    Sakano, Kiyoji
    Yano, Mamiko
    Ohnishi, Eriko
    Ono, Takao
    Kanai, Yasushi
    Ushiba, Shota
    Miyakawa, Naruto
    Tani, Shinsuke
    Kimura, Masahiko
    Watanabe, Yohei
    Inoue, Koichi
    Tanaka, Hidekazu
    Matsumoto, Kazuhiko
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2024, 63 (03)
  • [40] Label-Free LSPR-Vertical Microcavity Biosensor for On-Site SARS-CoV-2 Detection
    Zheng, Yuqiao
    Bian, Sumin
    Sun, Jiacheng
    Wen, Liaoyong
    Rong, Guoguang
    Sawan, Mohamad
    BIOSENSORS-BASEL, 2022, 12 (03):