Evaluation of beam modeling for small fields using a flattening filter-free beam

被引:2
作者
Kawahara D. [1 ,2 ]
Ozawa S. [3 ]
Nakashima T. [1 ]
Aita M. [1 ]
Tsuda S. [1 ]
Ochi Y. [1 ]
Okumura T. [1 ]
Masuda H. [1 ]
Ohno Y. [1 ]
Murakami Y. [3 ]
Nagata Y. [3 ]
机构
[1] Section of Radiation Therapy, Department of Clinical Support, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima
[2] Course of Medical and Dental Sciences, Graduate School of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima
[3] Department of Radiation Oncology, Institute of Biomedical and Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima
基金
日本学术振兴会;
关键词
Flattening filter-free (FFF) beam; Monte Carlo; Output factor; Small field;
D O I
10.1007/s12194-016-0365-2
中图分类号
学科分类号
摘要
The characteristics of a flattening filter-free (FFF) beam are different from those of a beam with a flattening filter. For small-field dosimetry, the beam data needed by the radiation treatment planning system (RTPS) includes the percent depth dose (PDD), off-center ratio (OCR), and output factor (OPF) for field sizes down to 3 × 3 cm2to calculate the beam model. The purpose of this study was to evaluate the accuracy of calculations for the FFF beam by the Eclipse™treatment planning system for field sizes smaller than 3 × 3 cm2(2 × 2 and 1 × 1 cm2). We used 6X and 10X FFF beams by the Varian TrueBeam™to produce. The AAA and AXB algorithms of the Eclipse were used to compare the Monte Carlo (MC) calculation and the measurements from three dosimeters, a diode detector, a PinPoint dosimeter, and EBT3 film. The PDD curves and the penumbra width in the OCR calculated by the Eclipse, measured data, and those from the MC calculations were in good agreement to within ±2.8 % and ±0.6 mm, respectively. However, the difference in the OPF values between AAA and AXB for a field size of 1 × 1 cm2was 5.3 % for the 6X FFF beam and 7.6 % for the 10X FFF beam. Therefore, we have to confirm the small field data that is included for the RTPS commission procedures. © 2016, Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:33 / 40
页数:7
相关论文
共 28 条
  • [1] Georg D., Knoos T., McClean B., Current status and future perspective of flattening filter free photon beams, Med Phys, 38, pp. 1280-1293, (2011)
  • [2] Mok E., Kielar K., Wang L., Et al., Evaluation of the accuracy of Eclipse AAA modeling for flattening filter free beam used for SBRT, Med Phys, 38, pp. 3711-3712, (2011)
  • [3] Das I.J., Ding G.X., Ahnesjo A., Et al., Small fields: nonequilibrium radiation dosimetry, Med Phys, 35, pp. 206-215, (2008)
  • [4] Duggan D.M., Coffey C.W., Et al., Small photon field dosimetry for stereotactic radiosurgery, Med Dosim, 23, pp. 153-159, (1998)
  • [5] Palmans H., Small and composite field dosimetry: the problems and recent progress. Standards, applications and quality assurance in medical radiation dosimetry, Proceedings of an international symposium, Vienna, pp. 161-180, (2011)
  • [6] Rice R.K., Hansen J.L., Svensson G.K., Et al., Measurements of dose distributions in small beams of 6X X-rays, Phys Med Biol, 32, pp. 1087-1099, (1987)
  • [7] McKerracher C., Thwaites D.I., Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition, Phys Med Biol, 44, pp. 2143-2160, (1999)
  • [8] Scott A.J.D., Kumar S., Nahum A.E., Et al., Characterizing the influence of detector density on dosimeter response in non-equilibrium small photon fields, Phys Med Biol, 57, pp. 4461-4476, (2012)
  • [9] Fenwick J.D., Kumar S., Scott A.J.D., Et al., Using cavity theory to describe the dependence on detector density of dosimeter response in non-equilibrium small fields, Phys Med Biol, 58, pp. 2901-2923, (2013)
  • [10] Heydarian M., Hoban P.W., Beddoe A.H., A comparison of dosimetry techniques in stereotactic radiosurgery, Phys Med Biol, 41, pp. 93-110, (1996)