The porosity of thermal sprayed coatings is usually a problem when coatings are used in wet corrosion application. The porosity allows media to penetrate to the surface of the base material. Corrosion spreads rapidly and the coating loses contact with the substrate and delaminates. This problem can be initiated by impregnating different polymers into the pores. An alternative approach has been tested in the present work to prevent corrosion of cemented carbide coated carbon steel in wet corrosion environments.