Mandibular fractures associated with endosteal implants

被引:24
作者
Chrcanovic B.R. [1 ]
Custódio A.L.N. [2 ,3 ,4 ]
机构
[1] Belo Horizonte, MG-CEP 30441-070, Av. Raja Gabaglia
[2] Departamento de Odontologia, Pontifícia Universidade Católica de Minas Gerais, 30535-610 Minas Gerais, Belo Horizonte, Av. Dom José Gaspar
[3] Oral and Maxillofacial Surgery Department, School of Dentistry, Pontifícia Universidade Católica de Minas Gerais, Belo Horizonte
[4] Department of Morphology, Institute of Biological Sciences, Universidade Federal de Minas Gerais, Belo Horizonte
关键词
Dental implant; Edentulous patient; Mandibular fracture;
D O I
10.1007/s10006-009-0171-7
中图分类号
学科分类号
摘要
Purpose: The purpose of this study is to report four cases of mandibular fractures associated with endosteal implants and to discuss prevention and treatment of these types of fractures. Discussion: To evaluate whether the patient's anatomy allows insertion of implants, radiological exams that demonstrate the height and the labial-lingual width are needed. To reduce the potential fracture problem, the mandible can be restrengthened with bone grafting techniques. The treatment of a fracture in an atrophic mandible is always a challenge because of the diminished central blood supply, the depressed vitality of the bone, and the dependence on the periosteal blood supply. The basic principles in fracture treatment are reduction and immobilization of the fractured site for restoration of form and function. Conclusions: If implants are placed in severe atrophic mandible, iatrogenic fracture of the mandible may occur during or after implant surgery because implant placement weakens the already-compromised mandible. A few millimeters of cortical bone should remain on both the labial and the lingual sites after the hole for insertion of an implant has been drilled. A 3-D surgical planning should be recommended at least in severe atrophic mandibles in order to prevent a severe reduction of bone tissue. © 2009 Springer-Verlag.
引用
收藏
页码:231 / 238
页数:7
相关论文
共 50 条
[1]  
Branemark P.-I., Hansson B.O., Adell R., Breine U., Lindstrom J., Hallen O., Ohman A., Osseointegrated implants in the treatment of the edentulous jaw: Experience from a ten-year period, Scand J Plast Reconstr Surg, 11, SUPPL. 16, pp. 1-132, (1977)
[2]  
Albrektsson T., A multicenter report on osseointegrated oral implants, J Prosthet Dent, 60, pp. 75-84, (1988)
[3]  
Binder T., Osteomyelitis and pathological fracture after implant placement in the edentulous mandible, Z Zahnärztl Implantol, 5, pp. 12-24, (1989)
[4]  
Goodarce C.J., Kan J.Y.K., Rungcharassaeng K., Clinical complications of osseointegrated implants, J Prosthet Dent, 81, pp. 537-552, (1999)
[5]  
Kan J.Y.K., Lozada J.L., Boyne P.J., Goodacre C.J., Rungcharassaeng K., Mandibular fracture after endosseous implant placement in conjunction with inferior alveolar nerve transposition: A patient treatment report, Int J Oral Maxillofac Implants, 12, pp. 655-659, (1997)
[6]  
Keller E.E., Reconstruction of the severely atrophic edentulous mandible with endosseous implants: A 10-year longitudinal study, J Oral Maxillofac Surg, 53, pp. 305-320, (1995)
[7]  
Mason M.E., Triplett R.G., Van Sickels J.E., Parel S.M., Mandibular fractures through endosseous cylinder implants: Report of four cases and review, J Oral Maxillofac Surg, 8, pp. 311-317, (1990)
[8]  
Neyt L., De Clercq C., Abeloos J., Mommaerts M., Onderkakkfracturen na het plaatsen van tandimplantaten (Mandibular fractures following inserting of dental implants), Acta Stomatol Belg, 90, pp. 251-258, (1993)
[9]  
Rothman S.L.G., Schwarz M.S., Chafetz N.I., High-resolution compurtized tomography and nuclear bone scanning in the diagnosis of postoperative stress fractures of the mandible: A clinical report, Int J Oral Maxillofac Implants, 10, pp. 765-768, (1995)
[10]  
Schug T., Dumbach J., Rodemer H., Unterkieferfraktur. Eine seltene implantologische Komplikation, Mund Kiefer GesichtsChir, 3, pp. 335-337, (1999)