The Contribution of Cortical and Cancellous Bone to Dual-Energy X-ray Absorptiometry Measurements in the Female Proximal Femur

被引:0
|
作者
G. A. Lundeen
S. L. Knecht
E. G. Vajda
R. D. Bloebaum
A. A. Hofmann
机构
[1] Bone and Joint Research Laboratory,
[2] Department of Veterans Affairs,undefined
[3] Salt Lake City Health Care System,undefined
[4] Salt Lake City,undefined
[5] UT 84148,undefined
[6] USA,undefined
来源
关键词
Key words:Accuracy – Cancellous bone – Cortical bone – DXA – Femur – Human;
D O I
暂无
中图分类号
学科分类号
摘要
Dual-energy X-ray absorptiometry (DXA) is the most common method for determining bone mineral density (BMD) in the proximal femur. However, there remain questions concerning the contribution of cortical and cancellous bone to this technology in the proximal femur. The purpose of this investigation was to identify structural and compositional characteristics of human bone in the proximal femur that significantly influence DXA BMD measurements. Twenty-four femora were obtained at autopsy from Caucasian females ranging in age from 17 to 92 years (mean ± SD, 61 ± 25 years). DXA scans were performed on each specimen with a Hologic QDR-2000 densitometer. Direct measurements were determined from proximal femoral sections for cancellous bone (volume fraction, ash fraction, cancellous cross-sectional area and percent cancellous cross-sectional area), cortical bone (thickness, ash fraction, porosity, cortical cross-sectional area and percent cortical cross-sectional area) and anteroposterior thickness. These parameters were compared with the associated DXA measurements by means of simple and multiple regressions. Cancellous volume fraction was the best predictor of variability of DXA measurements for both the neck and trochanter, with an R2 of 0.87 and 0.76, respectively (p<0.0001). There was only a minor influence of cortical factors such as thickness (neck and trochanter R2= 0.51 and 0.42, respectively, p<0.001) and trochanteric cross-sectional area (R2= 0.21, p<0.05). Although the accuracy for determining specific components of the proximal femur was low, the DXA BMD measurement was a strong predictor of cancellous bone factors, but not cortical bone factors that have been shown to change significantly with age.
引用
收藏
页码:192 / 198
页数:6
相关论文
共 50 条
  • [21] Bone mineral density measurements in otosclerosis using dual-energy X-ray absorptiometry
    Tonuk, S. B.
    Koybasi, S.
    Bicer, Y. O.
    Alkan Temel, S.
    CLINICAL OTOLARYNGOLOGY, 2016, 41 (02) : 149 - 153
  • [22] Relationship between bone strength and dual-energy X-ray absorptiometry measurements in pigs
    Nielsen, D. H.
    McEvoy, F. J.
    Madsen, M. T.
    Jensen, J. B.
    Svalastoga, E.
    JOURNAL OF ANIMAL SCIENCE, 2007, 85 (03) : 667 - 672
  • [23] Total body bone measurements in spinal osteoporosis by dual-energy X-ray absorptiometry
    Revilla, RM
    Hernandez, ER
    Villa, LF
    Seco, C
    SanchezAtrio, A
    Rico, H
    CALCIFIED TISSUE INTERNATIONAL, 1997, 61 (01) : 44 - 47
  • [24] DUAL-ENERGY X-RAY ABSORPTIOMETRY MEASUREMENTS OF BONE-MINERAL DENSITY IN MYELOMA
    HOLMES, JA
    EVANS, WD
    COLES, RJ
    RAMSAHOYE, B
    WHITTAKER, JA
    EUROPEAN JOURNAL OF HAEMATOLOGY, 1994, 53 (05) : 309 - 311
  • [25] Dual-energy X-ray absorptiometry in predicting mechanical characteristics of rat femur
    Järvinen, TLN
    Sievänen, H
    Kannus, P
    Järvinen, M
    BONE, 1998, 22 (05) : 551 - 558
  • [26] COMPARISON OF DUAL ENERGY X-RAY ABSORPTIOMETRY OF THE PROXIMAL FEMUR WITH MORPHOLOGIC DATA
    HUBSCH, P
    KOCANDA, H
    YOUSSEFZADEH, S
    SCHNEIDER, B
    KAINBERGER, F
    SEIDL, G
    KURTARAN, A
    GRUBER, S
    ACTA RADIOLOGICA, 1992, 33 (05) : 477 - 481
  • [27] How Femur Positioning Affects Dual-energy X-ray Absorptiometry Outcomes
    Ammar, Ali
    Adachi, Jonathan
    Quenneville, Cheryl
    JOURNAL OF BONE AND MINERAL RESEARCH, 2023, 38 : 248 - 248
  • [28] Reliability of Lateral Distal Femur Dual-Energy X-Ray Absorptiometry Measures
    Mueske, Nicole M.
    Chan, Linda S.
    Wren, Tishya A. L.
    JOURNAL OF CLINICAL DENSITOMETRY, 2014, 17 (04) : 522 - 527
  • [29] DUAL-ENERGY X-RAY ABSORPTIOMETRY OF THE FOREARM
    ROOS, JC
    TENKROODE, K
    LIPS, P
    TEULE, GJJ
    VANLINGEN, A
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P110 - P111
  • [30] CORR Insights® : Proximal Femur Hounsfield Units on CT Colonoscopy Correlate With Dual-energy X-ray Absorptiometry
    Cheng, Wayne
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2019, 477 (04) : 861 - 862