Effects of Interfacial Properties of a Surface Modified Surface Plasmon Resonance Chip on Protein Immobilization Performance

被引:0
|
作者
Juan Wu
Yanbin Jiang
Lishi Wang
Qiang Zeng
机构
[1] South China University of Technology,School of Chemistry and Chemical Engineering
[2] South China University of Technology,State Key Laboratory of Pulp and Paper Engineering
来源
Analytical Sciences | 2017年 / 33卷
关键词
Surface plasmon resonance array; surface modification; protein immobilization; nonspecific adsorption;
D O I
暂无
中图分类号
学科分类号
摘要
In order to confirm the correlation between interfacial properties of modified surface plasmon resonance (SPR) chips and their SPR responses to immobilized anti-IgG, SPR chips were modified by mercaptoundecanoic acid, poly(ethylene glycol) diacrylate (PEG), PEG-based copolymer and cyclodextrin coupled PEG using self-assembled or radical polymerization methods. The resulting interfacial properties such as film thickness and hydrophilicity were characterized by AFM, elliptic polarization scanners and contact angle meter. Immobilization of human IgG on the modified chips was achieved by EDC/NHS activation through an amide bond. The association between fixed IgG and free anti-IgG was reflected by the variation of SPR responses and the binding ability was evaluated by Langmuir isotherms. As observed, the adsorption between IgG and anti-IgG was affected by the interfacial properties of different modifiers, such that a chip with a thinner and more hydrophilic layer may result in a higher SPR response, producing a larger adsorption equilibrium constant for protein interaction.
引用
收藏
页码:481 / 485
页数:4
相关论文
共 50 条
  • [31] Effect of antibody immobilization strategies on the analytical performance of a surface plasmon resonance-based immunoassay
    Vashist, Sandeep Kumar
    Dixit, Chandra Kumar
    MacCraith, Brian D.
    O'Kennedy, Richard
    ANALYST, 2011, 136 (21) : 4431 - 4436
  • [32] Effects of light source on the performance of a Kretschmann surface plasmon resonance sensor
    Liu, Sha
    Li, Min
    Gong, Chaoyang
    Gao, Hongyun
    LASER PHYSICS, 2016, 26 (06)
  • [33] Effects of receptor thickness on localised surface plasmon resonance sensing performance
    Ma, Wenying
    Yang, Huan
    Cai, Ju
    Wang, Weimin
    Xiong, Wei
    Yao, Jun
    MICRO & NANO LETTERS, 2011, 6 (10) : 863 - 866
  • [34] Trends in interfacial design for surface plasmon resonance based immunoassays
    Shankaran, Dhesingh Ravi
    Miura, Norio
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2007, 40 (23) : 7187 - 7200
  • [35] Protein immobilization on polypropylene surface modified by photografting
    College of Materials Science and Engineering, Beijing University of Chemical Technology, Beijing 100029, China
    Beijing Huagong Daxue Xuebao, 2008, 4 (61-64):
  • [36] Plasma-Fabricated Surface Plasmon Resonance Chip for Biosensing
    Gandhiraman, Ram P.
    Manickam, Gowri
    Kerr, Laura
    Dixit, Chandra K.
    Doyle, Colin
    Williams, David E.
    Daniels, Stephen
    AUSTRALIAN JOURNAL OF CHEMISTRY, 2015, 68 (03) : 447 - 452
  • [37] Localized surface plasmon resonance biosensor integrated with microfluidic chip
    Chengjun Huang
    Kristien Bonroy
    Gunter Reekmans
    Wim Laureyn
    Katarina Verhaegen
    Iwijn De Vlaminck
    Liesbet Lagae
    Gustaaf Borghs
    Biomedical Microdevices, 2009, 11 : 893 - 901
  • [38] On-chip processing of droplets for surface plasmon resonance analysis
    Okubo, Kyohei
    Yoshizumi, Yoshitaka
    Asakawa, Kiyoshi
    Suzuki, Hiroaki
    Yokokawa, Masatoshi
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 190 : 975 - 981
  • [39] Localized surface plasmon resonance biosensor integrated with microfluidic chip
    Huang, Chengjun
    Bonroy, Kristien
    Reekmans, Gunter
    Laureyn, Wim
    Verhaegen, Katarina
    De Vlaminck, Iwijn
    Lagae, Liesbet
    Borghs, Gustaaf
    BIOMEDICAL MICRODEVICES, 2009, 11 (04) : 893 - 901
  • [40] Integrated holographic grating chip for surface plasmon resonance sensing
    Pedersen, HC
    Zong, WY
    Sorensen, MH
    Thirstrup, C
    OPTICAL ENGINEERING, 2004, 43 (11) : 2505 - 2510