Removal and recovery of ammonia from simulated wastewater using Ti3C2Tx MXene in flow electrode capacitive deionization

被引:0
作者
Naqsh E. Mansoor
Luis A. Diaz
Christopher E. Shuck
Yury Gogotsi
Tedd E. Lister
David Estrada
机构
[1] Boise State University,Micron School of Materials Science and Engineering
[2] Idaho National Laboratory,A.J. Drexel Nanomaterials Institute and Department of Materials Science and Engineering
[3] Drexel University,Center for Advanced Energy Studies
[4] Boise State University,undefined
来源
npj Clean Water | / 5卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Flowing electrode capacitive deionization systems (FE-CDI) have recently garnered attention because of their ability to prevent cross contamination and operate in uninterrupted cycles ad infinitum. Typically, FE-CDI electrodes suffer from low conductivity, reducing deionization performance. Utilization of higher mass loadings to combat this leads to poor rheological properties. Herein, Ti3C2Tx MXene was introduced as 1 mg mL−1 slurry electrodes in an FE-CDI system for the removal and recovery of ammonia from simulated agricultural wastewater. The electrode performance was evaluated by operating the FE-CDI system with a feed solution of 500 mg L−1 NH4Cl running in batch mode at a constant voltage of 1.20 and −1.20 V in charging and discharging modes, respectively. Despite the low loading, Ti3C2Tx flowing electrodes showed markedly improved performance, achieving 60% ion removal efficiency in a saturation time of 115 min with an adsorption capacity of 460 mg g−1. To understand the high adsorption performance of the electrodes, physiochemical and structural analysis was done via a variety of characterization techniques such as SEM, TEM, XRD, DLS, and Raman spectroscopy. Cyclic voltammetry and galvanostatic charge/discharge profiles were obtained to evaluate the electrochemical properties of the electrodes. The system proved to be an energy-saving technology by exhibiting a charge efficiency of 58–70% while operating at an energy consumption of 0.45 kWh kg−1. A 92% regeneration efficiency showed that the electrodes were stable and suitable for long term and scalable usage. The results demonstrate that MXenes have the potential to improve the FE-CDI process for energy-efficient removal and recovery of ammonia.
引用
收藏
相关论文
共 181 条
[1]  
Macknick J(2012)Operational water consumption and withdrawal factors for electricity generating technologies: a review of existing literature Environ. Res. Lett. 7 045802-498
[2]  
Newmark R(1984)Ammonia: its effects on biological systems, metabolic hormones, and reproduction J. Dairy Sci. 67 481-296
[3]  
Heath G(2008)An earth-system perspective of the global nitrogen cycle Nature 451 293-214
[4]  
Hallett KC(1996)Chronic lung disease secondary to ammonia inhalation injury: a report on three cases Am. J. Ind. Med. 29 209-396
[5]  
Visek WJ(2019)Consequences of the Clean Water Act and the demand for water quality Q. J. Econ. 134 349-31
[6]  
Gruber N(2018)Critical review of abatement of ammonia from wastewater J. Mol. Liq. 261 21-810
[7]  
Galloway JN(2018)Approaches and processes for ammonia removal from side-streams of municipal effluent treatment plants Bioresour. Technol. 268 797-132
[8]  
De La Hoz RE(2019)Current Trends and future prospects of ammonia removal in wastewater: a comprehensive review on adsorptive membrane development Sep. Purif. Technol. 213 114-164
[9]  
Schlueter DP(2018)Advanced strategies to improve nitrification process in sequencing batch reactors—a review J. Environ. Manag. 218 154-3856
[10]  
Rom WN(2010)Capacitive deionization as an electrochemical means of saving energy and delivering clean water. comparison to present desalination practices: will it compete? Electrochim. Acta 55 3845-192