Study of Fluorite-Containing Fluxes by Scanning Electron Microscopy

被引:0
|
作者
O. K. Tokovoi
机构
[1] South Ural State University,
来源
Metallurgist | 2015年 / 58卷
关键词
fluorite; corrosion-resistant steel; extra-furnace treatment; electron microscopy;
D O I
暂无
中图分类号
学科分类号
摘要
Scanning electron microscopy is used to study fluxes used in ESSW-6 of the Chelyabinsk Metallurgical Combine for producing refining slag in a steel-pouring ladle during extra-furnace treatment of steel by AKOS (complex steel processing facility). Three forms of flux containing feldspar are studied: fluorite briquettes FB 85 (TU 48-15-29–91) and fluorite concentrates FK 85 and FK 92 (GOST 29220–91). The average specimen chemical composition and its individual fragments are studied. It is established that for extra-furnace treatment of low-carbon stainless steel it is most preferable to use fluorite concentrate F 92 with a high basic element concentration and low (less than 3%) carbon content.
引用
收藏
页码:880 / 882
页数:2
相关论文
共 50 条
  • [1] STUDY OF FLUORITE-CONTAINING FLUXES BY SCANNING ELECTRON MICROSCOPY
    Tokovoi, O. K.
    METALLURGIST, 2015, 58 (9-10) : 880 - 882
  • [2] The endolymphatic sac: A scanning and transmission electron microscopy study
    Qvortrup, K
    Bretlau, P
    ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 2002, 64 (02): : 129 - 137
  • [3] THE STUDY OF RED BLOOD CELLS BY SCANNING ELECTRON MICROSCOPY
    Mamayeva, S. N.
    Munkhalova, Ya. A.
    Kononova, I. V.
    Dyakonov, A. A.
    Koryakina, V. N.
    Shutova, V. V.
    Maksimov, G. V.
    MORDOVIA UNIVERSITY BULLETIN, 2016, 26 (03): : 381 - 390
  • [4] Morphologic study of dog flea species by scanning electron microscopy
    Nagy, Agnes
    Cozma, V.
    Tudoran, L. Barbu
    BULLETIN OF THE UNIVERSITY OF AGRICULTURAL SCIENCES AND VETERINARY MEDICINE, VOL 63, 2006: VETERINARY MEDICINE, 2006, 63 : 465 - 465
  • [5] Optical microscopy versus scanning electron microscopy in urolithiasis
    Marickar, Y. M. Fazil
    Lekshmi, P. R.
    Varma, Luxmi
    Koshy, Peter
    UROLOGICAL RESEARCH, 2009, 37 (05): : 293 - 297
  • [6] Optical microscopy versus scanning electron microscopy in urolithiasis
    Y. M. Fazil Marickar
    P. R. Lekshmi
    Luxmi Varma
    Peter Koshy
    Urological Research, 2009, 37 : 293 - 297
  • [7] Model Validation for Scanning Electron Microscopy
    Ridzel, O. Yu.
    Yamane, W.
    Mansaray, I.
    Villarrubia, J. S.
    METROLOGY, INSPECTION, AND PROCESS CONTROL XXXVII, 2023, 12496
  • [8] An electron microscopy study of the structure of polyelectrolyte microcapsules containing protein and containing no protein
    Kazakova, L. I.
    Dubrovskii, A. V.
    Moshkov, D. A.
    Shabarchina, L. I.
    Sukhorukov, B. I.
    BIOFIZIKA, 2007, 52 (05): : 850 - 854
  • [9] Immunohistochemical Identification of Decorin and Biglycan in Human Dentin: A Correlative Field Emission Scanning Electron Microscopy/Transmission Electron Microscopy Study
    G. Orsini
    A. Ruggeri
    A. Mazzoni
    V. Papa
    G. Mazzotti
    R. Di Lenarda
    L. Breschi
    Calcified Tissue International, 2007, 81 : 39 - 45
  • [10] Immunohistochemical identification of decorin and biglycan in human dentin: A correlative field emission scanning electron Microscopy/Transmission electron microscopy study
    Orsini, G.
    Ruggeri, A., Jr.
    Mazzoni, A.
    Papa, V.
    Mazzotti, G.
    Di Lenarda, R.
    Breschi, L.
    CALCIFIED TISSUE INTERNATIONAL, 2007, 81 (01) : 39 - 45