Normal reference values for mechanical mitral prosthetic valve inner diameters and areas assessed by two-dimensional and real-time three-dimensional transesophageal echocardiography

被引:0
作者
Macit Kalçık
Mehmet Özkan
Sabahattin Gündüz
Mustafa Ozan Gürsoy
Mahmut Yesin
Emrah Bayam
Ahmet Güner
Semih Kalkan
Süleyman Karakoyun
Halil İbrahim Tanboğa
机构
[1] Hitit University,Faculty of Medicine, Department of Cardiology
[2] Koşuyolu Kartal Heart Training and Research Hospital,Department of Cardiology
[3] Ardahan University,Division of Health Sciences
[4] Izmir Katip Çelebi University,Department of Cardiology
[5] Atatürk Training and Research Hospital,Faculty of Medicine, Department of Cardiology
[6] Kars Kafkas University,Department of Cardiology
[7] Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Training and Research Hospital,Faculty of Medicine, Department of Cardiology
[8] Nisantasi University,undefined
来源
The International Journal of Cardiovascular Imaging | 2021年 / 37卷
关键词
Echocardiography; Inner diameter; Orifice area; Prosthetic valve; Transesophageal echocardiography;
D O I
暂无
中图分类号
学科分类号
摘要
It was previously observed that two dimensional (2D) Doppler derived and real-time three-dimensional (RT-3D) directly measured valve areas were smaller than reported manufacturer sizes. It may be helpful to obtain the ranges of inner diameters (IDs) and the geometric orifice area (GOA) during evaluation of prosthetic mitral valves. In this study, we aimed to provide reference dimensional parameters of bileflet mitral mechanical prosthetic valves. Patients with recent mitral valve replacement were examined by 2D and RT-3D transesophageal echocardiography (TEE) in the early postoperative period when the presence of pannus overgrowth was unlikely. Measurements of 2D IDs, 3D hinge to hinge (HHD) and edge to edge diameters (EED) and 3D GOA were obtained and compared with reported manufacturer sizes and areas. This study enrolled 126 patients with mitral prosthetic valves (38 ATS, 42 Carbomedics, 46 St. Jude Medical, all bileaflet). The measured 2D and 3D IDs and GOA were significantly smaller than reported manufacturer sizes in the majority of the valve sizes. This RT-3D TEE-guided study provides ranges of reference values for directly measured IDs and GOA of the three most commonly used mechanical mitral prosthetic valve types for the first time in a relatively large series.
引用
收藏
页码:547 / 557
页数:10
相关论文
共 79 条
  • [1] Lancellotti P(2016)Recommendations for the imaging assessment of prosthetic heart valves: a report from the European Association of Cardiovascular Imaging endorsed by the Chinese Society of Echocardiography, the Inter-American Society of Echocardiography, and the Brazilian Department of Cardiovascular Imaging Eur Heart J Cardiovasc Imaging 17 589-590
  • [2] Pibarot P(2009)Recommendations for evaluation of prosthetic valves with echocardiography and Doppler ultrasound : a report from the American Society of Echocardiography's Guidelines and Standards Committee and the task force on prosthetic valves, developed in conjunction with the American College of Cardiology Cardiovascular Imaging Committee, Cardiac Imaging Committee of the American Heart Association, the European Association of Echocardiography, a registered branch of the European Society of
  • [3] Chambers J(2008)Real-time three-dimensional transesophageal echocardiography in valve disease: comparison with surgical findings and evaluation of prosthetic valves J Am Soc Echocardiogr 21 1347-1354
  • [4] Zoghbi WA(2013)Real-time three-dimensional transesophageal echocardiography in the assessment of mechanical prosthetic mitral valve ring thrombosis Am J Cardiol 112 977-983
  • [5] Chambers JB(2010)Real-time 3D TEE for the diagnosis of right-sided endocarditis in patients with prosthetic devices JACC Cardiovasc Imaging 3 325-327
  • [6] Dumesnil JG(2009)Real-time 3-dimensional transesophageal echocardiography in the evaluation of post-operative mitral annuloplasty ring and prosthetic valve dehiscence J Am Coll Cardiol 53 1543-1547
  • [7] Sugeng L(2012)Thrombotic obstruction of mechanical prosthetic valve in mitral position the old "x-ray" fights the new 3-dimensional transesophageal echocardiography J Am Coll Cardiol 59 e11-989
  • [8] Shernan SK(2010)Diagnosis of the prosthetic heart valve pannus formation with real-time three-dimensional transoesophageal echocardiography Eur J Echocardiogr 11 E17-93
  • [9] Weinert L(2016)A global perspective on mechanical prosthetic heart valve thrombosis: diagnostic and therapeutic challenges Anatol J Cardiol 16 980-201
  • [10] Ozkan M(2015)Sixty-four-section cardiac computed tomography in mechanical prosthetic heart valve dysfunction: thrombus or pannus Circ Cardiovasc Imaging 8 e003246-7