Synthesis, characterisation and cytotoxicity of gold microwires for ultra-sensitive biosensor development

被引:0
|
作者
Nurul Akmal Che Lah
Robert Gray
Sonia Trigueros
机构
[1] University Malaysia Pahang,Innovative Manufacturing, Mechatronics and Sports Lab (iMAMS), Faculty of Manufacturing and Mechatronics Engineering Technology
[2] University College London,Department of Zoology
[3] University of Oxford,undefined
来源
Microbial Cell Factories | / 20卷
关键词
Biosensor; Biomarkers; Antimicrobial; Cytotoxicity; Gold microwires;
D O I
暂无
中图分类号
学科分类号
摘要
With the long-term goal of developing an ultra-sensitive microcantilever-based biosensor for versatile biomarker detection, new controlled bioreceptor-analytes systems are being explored to overcome the disadvantages of conventional ones. Gold (Au) microwires have been used as a probe to overcome the tolerance problem that occurs in response to changes in environmental conditions. However, the cytotoxicity of Au microwires is still unclear. Here, we examined the cytotoxicity of Au microwires systems using both commercial and as-synthesised Au microwires. In vitro experiments show that commercial Au microwires with an average quoted length of 5.6 µm are highly toxic against Gram-negative Escherichia coli (E. coli) at 50 µg/mL. However, this toxicity is due to the presence of CTAB surfactant not by the microwires. Conversely, the as-synthesised Au microwires show non-cytotoxicity even at the maximum viable concentration (330 µg/mL). These findings may lead to the development of potentially life-saving cytotoxicity-free biosensors for an early diagnostic of potential diseases.
引用
收藏
相关论文
共 50 条
  • [41] Designing a novel, ultra-sensitive, and biocompatible electrochemical nano-biosensor for the detection of tryptophan and bovine serum albumin using zirconium dioxide nanostructures
    Basavanagoudra, Hanumantagouda
    Jangannanavar, Vijayakumar
    Vaddar, Husenappa
    Patil, Mallikarjun K.
    Inamdar, Sanjeev R.
    Anegundi, Sunilkumar
    Goudar, Kotresh M.
    CHEMICAL PHYSICS IMPACT, 2024, 8
  • [42] Normal-incidence type solution immersed silicon (SIS) biosensor for ultra-sensitive, label-free detection of cardiac troponin I
    Kim, Dong Hyung
    Chegal, Won
    Cho, Yong Jai
    O, Sang Won
    Le, Long Van
    Diware, Mangesh S.
    Paek, Se-Hwan
    Kim, Young Dong
    Cho, Hyun Mo
    BIOSENSORS & BIOELECTRONICS, 2020, 168 (168)
  • [43] Real-time ultra-sensitive detection of SARS-CoV-2 by quasi-freestanding epitaxial graphene-based biosensor
    Kim, Soaram
    Ryu, Heeju
    Tai, Sheldon
    Pedowitz, Michael
    Rzasa, John Robertson
    Pennachio, Daniel J.
    Hajzus, Jenifer R.
    Milton, Donald K.
    Myers-Ward, Rachael
    Daniels, Kevin M.
    BIOSENSORS & BIOELECTRONICS, 2022, 197
  • [44] Highly selective and sensitive biosensor for cysteine detection based on in situ synthesis of gold nanoparticles/graphene nanocomposites
    Zhang, Yang
    Yang, Ankang
    Zhang, Xiaofang
    Zhao, Hong
    Li, Xiangjun
    Yuan, Zhuobin
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2013, 436 : 815 - 822
  • [45] A novel chemometric-amperometric biosensor for selective and ultra-sensitive determination of Streptococcus pneumoniae based on detection of a protein marker: A suitable and reliable alternative method
    Jalili, Faramarz
    Farshadnia, Pedram
    Abiri, Ramin
    Alvandi, Amirhooshang
    Kooti, Sara
    Jalalvand, Ali R.
    MICROCHEMICAL JOURNAL, 2023, 193
  • [46] An ultra-sensitive fluorescence biosensor with rolling circle amplification and CRISPR/Cas12a one-pot system for FEN1 detection
    He, Xiang-Lan
    Song, Yong-Li
    Ma, Li-Yun
    Jiang, Ming
    Xu, Li
    Yu, Xu
    TALANTA, 2025, 283
  • [47] Convenient and ultra-sensitive fluorescence detection of bovine serum albumin by using Rhodamine-6G modified gold nanoparticles in biological samples
    Verma, Vikas Kumar
    Tapadia, Kavita
    Maharana, Tungabidya
    Sharma, Ashima
    LUMINESCENCE, 2018, 33 (08) : 1408 - 1414
  • [48] Simultaneous and ultra-sensitive SERS detection of SLPI and IL-18 for the assessment of donor kidney quality using black phosphorus/gold nanohybrids
    Chen, Hui
    Luo, Caixia
    Xing, Longqiang
    Guo, Huiru
    Ma, Pei
    Zhang, Xuedian
    Zeng, Li
    Sui, Mingxing
    OPTICS EXPRESS, 2022, 30 (02) : 1452 - 1465
  • [49] Ultra-sensitive biosensor based on genetically engineered acetylcholinesterase immobilized in poly (vinyl alcohol)/Fe-Ni alloy nanocomposite for phosmet detection in olive oil
    El-Moghazy, A. Y.
    Soliman, E. A.
    Ibrahim, H. Z.
    Noguer, T.
    Marty, J. -L.
    Istamboulie, G.
    FOOD CHEMISTRY, 2016, 203 : 73 - 78
  • [50] Catalytic activity-modulated etching of plasmonic gold nanorods enabled ultra-sensitive colorimetric strategy for Early-Stage cancer diagnosis
    Ding, Caiping
    Li, Ming
    Chen, Weiwei
    Chen, Zikang
    Guo, Zhanhu
    Bin Xu, Ben
    Zhang, Xuehua
    Guo, Zhiyong
    Huang, Youju
    CHEMICAL ENGINEERING JOURNAL, 2023, 476