Synthesis, characterisation and cytotoxicity of gold microwires for ultra-sensitive biosensor development

被引:0
|
作者
Nurul Akmal Che Lah
Robert Gray
Sonia Trigueros
机构
[1] University Malaysia Pahang,Innovative Manufacturing, Mechatronics and Sports Lab (iMAMS), Faculty of Manufacturing and Mechatronics Engineering Technology
[2] University College London,Department of Zoology
[3] University of Oxford,undefined
来源
Microbial Cell Factories | / 20卷
关键词
Biosensor; Biomarkers; Antimicrobial; Cytotoxicity; Gold microwires;
D O I
暂无
中图分类号
学科分类号
摘要
With the long-term goal of developing an ultra-sensitive microcantilever-based biosensor for versatile biomarker detection, new controlled bioreceptor-analytes systems are being explored to overcome the disadvantages of conventional ones. Gold (Au) microwires have been used as a probe to overcome the tolerance problem that occurs in response to changes in environmental conditions. However, the cytotoxicity of Au microwires is still unclear. Here, we examined the cytotoxicity of Au microwires systems using both commercial and as-synthesised Au microwires. In vitro experiments show that commercial Au microwires with an average quoted length of 5.6 µm are highly toxic against Gram-negative Escherichia coli (E. coli) at 50 µg/mL. However, this toxicity is due to the presence of CTAB surfactant not by the microwires. Conversely, the as-synthesised Au microwires show non-cytotoxicity even at the maximum viable concentration (330 µg/mL). These findings may lead to the development of potentially life-saving cytotoxicity-free biosensors for an early diagnostic of potential diseases.
引用
收藏
相关论文
共 50 条
  • [1] Synthesis, characterisation and cytotoxicity of gold microwires for ultra-sensitive biosensor development
    Lah, Nurul Akmal Che
    Gray, Robert
    Trigueros, Sonia
    MICROBIAL CELL FACTORIES, 2021, 20 (01)
  • [2] Ultra-sensitive detection of cysteine by gold nanorod assembly
    Huang, Haowen
    Liu, Xuanyong
    Hu, Tao
    Chu, Paul K.
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (09) : 2078 - 2083
  • [3] Ultra-sensitive biosensor based on SU-8 planar interferometer
    Shew, BY
    Kuo, CH
    Tsai, YH
    Transducers '05, Digest of Technical Papers, Vols 1 and 2, 2005, : 1784 - 1787
  • [4] An ultra-sensitive metasurface biosensor for instant cancer detection based on terahertz spectra
    Wang, Peiliang
    Lou, Jing
    Yu, Yun
    Sun, Lang
    Sun, Lan
    Fang, Guangyou
    Chang, Chao
    NANO RESEARCH, 2023,
  • [5] Ultra-sensitive acoustic biosensor based on a 1D phononic crystal
    Khateib, Fatma
    Mehaney, Ahmed
    Amin, Rafat M.
    Aly, Arafa H.
    PHYSICA SCRIPTA, 2020, 95 (07)
  • [6] An ultra-sensitive biosensor based on surface plasmon resonance and weak value amplification
    Zhang, Lizhong
    He, Mingyi
    Xu, Yang
    Guo, Cuixia
    Zhou, Chongqi
    Guan, Tian
    FRONTIERS IN CHEMISTRY, 2024, 12
  • [7] An ultra-sensitive metasurface biosensor for instant cancer detection based on terahertz spectra
    Peiliang Wang
    Jing Lou
    Yun Yu
    Lang Sun
    Lan Sun
    Guangyou Fang
    Chao Chang
    Nano Research, 2023, 16 (5) : 7304 - 7311
  • [8] The Vertical Strained Impact Ionization MOSFET (VESIMOS) for Ultra-Sensitive Biosensor Application
    Saad, Ismail
    Hazwani, Andee B.
    Zuhir, Mohd. H.
    Seng, Bun C.
    Bolong, N.
    2015 IEEE REGIONAL SYMPOSIUM ON MICRO AND NANOELECTRONICS (RSM), 2015, : 1 - 4
  • [9] Characterization of Vertical Strained SiGe Impact Ionization MOSFET for Ultra-Sensitive Biosensor Application
    Saad, Ismail
    Zuhir, Mohd H.
    Seng, Bun C.
    Khairul, A. M.
    Ghosh, Bablu
    Bolong, N.
    Ismail, Razali
    2014 IEEE INTERNATIONAL CONFERENCE ON SEMICONDUCTOR ELECTRONICS (ICSE), 2014, : 154 - 157
  • [10] An ultra-sensitive Au nanoparticles functionalized DNA biosensor for electrochemical sensing of mercury ions
    Zhang, Yanyan
    Zhang, Cong
    Ma, Rui
    Du, Xin
    Dong, Wenhao
    Chen, Yuan
    Chen, Qiang
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 75 : 175 - 181