Evaluation of 4D dose to a moving target with Monte Carlo dose calculation in stereotactic body radiotherapy for lung cancer

被引:5
作者
Matsugi K. [1 ]
Nakamura M. [2 ]
Miyabe Y. [2 ]
Yamauchi C. [1 ]
Matsuo Y. [2 ]
Mizowaki T. [2 ]
Hiraoka M. [2 ]
机构
[1] Radiation Oncology Division, Shiga Medical Center for Adults, Moriyama 524-8524
[2] Department of Radiation Oncology and Image-applied Therapy, Graduate School of Medicine, Kyoto University, Shogoin, Sakyo-ku, Kyoto 606-8507
基金
日本学术振兴会;
关键词
4D dose calculation; Deformable image registration; Monte Carlo; Stereotactic body radiotherapy;
D O I
10.1007/s12194-012-0193-y
中图分类号
学科分类号
摘要
We evaluated the four-dimensional (4D) dose to a moving target by a Monte Carlo dose calculation algorithm in stereotactic body radiation therapy (SBRT) planning based on the isocenter dose prescription. 4D computed tomography scans were performed for 12 consecutive patients who had 14 tumors. The gross tumor volume (GTV) and internal target volume (ITV) were contoured manually, and the planning target volume (PTV) was defined as the ITV with a 5-mm margin. The beam apertures were shaped into the PTV plus a 5-mm leaf margin. The prescription dose was 48 Gy in 4 fractions at the isocenter. The GTV dose was calculated by accumulation of respiratory-phase dose distributions that were mapped to a reference images, whereas the ITV and PTV doses were calculated with the respiration-averaged images. The doses to 99 % (D99) of the GTV, ITV, and PTV were 90.2, 89.3, and 82.0 %, respectively. The mean difference between the PTV D99 and GTV D99 was -9.1 % (range -13.4 to -4.0 %), and that between the ITV and GTV was -1.1 % (range -5.5 to 1.9 %). The mean homogeneity index (HI) for the GTV, ITV, and PTV was 1.14, 1.15, and 1.26, respectively. Significant differences were observed in the D99 and HI between the PTV and GTV, whereas no significant difference was seen between the ITV and GTV. When SBRT planning is performed based on the isocenter dose prescription with a 5-mm PTV margin and a 5-mm leaf margin, the ITV dose provides a good approximation of the GTV dose. © 2012 Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:233 / 240
页数:7
相关论文
共 34 条
  • [1] Nagata Y., Negoro Y., Aoki T., Mizowaki T., Takayama K., Kokubo M., Et al., Clinical outcomes of 3D conformal hypofractionated single high-dose radiotherapy for one or two lung tumors using a stereotactic body frame, Int J Radiat Oncol Biol Phys, 52, pp. 1041-1046, (2002)
  • [2] Onimaru R., Shirato H., Shimizu S., Kitamura K., Xu B., Fukumoto S., Et al., Tolerance of organs at risk in small-volume, hypofractionated, image-guided radiotherapy for primary and metastatic lung cancers, Int J Radiat Oncol Biol Phys, 56, pp. 126-135, (2003)
  • [3] Timmerman R., Papiez L., McGarry R., Likes L., Desrosiers C., Frost S., Et al., Extracranial stereotactic radioablation: Results of a phase i study in medically inoperable stage i non-small cell lung cancer, Chest, 124, pp. 1946-1955, (2003)
  • [4] Wulf J., Haedinger U., Oppitz U., Thiele W., Mueller G., Flentje M., Stereotactic radiotherapy for primary lung cancer and pulmonary metastases: A noninvasive treatment approach in medically inoperable patients, Int J Radiat Oncol Biol Phys, 60, pp. 186-196, (2004)
  • [5] Matsugi K., Narita Y., Sawada A., Nakamura M., Miyabe Y., Matsuo Y., Et al., Measurement of interfraction variations in position and size of target volumes in stereotactic body radiotherapy for lung cancer, Int J Radiat Oncol Biol Phys, 75, pp. 543-548, (2009)
  • [6] Keall P.J., Mageras G.S., Balter J.M., Emery R.S., Forster K.M., Jiang S.B., Et al., The management of respiratory motion in radiation oncology report of AAPM Task Group 76, Med Phys, 33, pp. 3874-3900, (2006)
  • [7] Matsuo Y., Takayama K., Nagata Y., Kunieda E., Tateoka K., Ishizuka N., Et al., Interinstitutional variations in planning for stereotactic body radiation therapy for lung cancer, Int J Radiat Oncol Biol Phys, 68, pp. 416-425, (2007)
  • [8] Nakamura M., Miyabe Y., Matsuo Y., Kamomae T., Nakata M., Yano S., Et al., Experimental validation of heterogeneity-corrected dose-volume prescription on respiratory-averaged CT images in stereotactic body radiotherapy for moving tumors, Med Dosim, 37, pp. 20-25, (2012)
  • [9] Keall P.J., 4-Dimensional computed tomography imaging and treatment planning, Semin Radiat Oncol, 14, pp. 81-90, (2004)
  • [10] Onishi H., Shirato H., Nagata Y., Hiraoka M., Fujino M., Gomi K., Et al., Hypofractionated stereotactic radiotherapy (HypoFXSRT) for stage i non-small cell lung cancer: Updated results of 257 patients in a Japanese multi-institutional study, J Thoracic Oncol, 2, (2007)