Sensor-based gait analyses of the six-minute walk test identify qualitative improvement in gait parameters of people with multiple sclerosis after rehabilitation

被引:0
作者
Pål Berg-Hansen
Stine Marit Moen
Andreas Austeng
Victor Gonzales
Thomas Dahl Klyve
Henrik Negård
Trine Margrethe Seeberg
Elisabeth Gulowsen Celius
Frédéric Meyer
机构
[1] Oslo University Hospital,Department of Neurology
[2] MS Center Hakadal,Department of Informatics
[3] University of Oslo,Institute of Clinical Medicine
[4] SINTEF Digital,undefined
[5] Smart Sensor Systems,undefined
[6] University of Oslo,undefined
来源
Journal of Neurology | 2022年 / 269卷
关键词
Multiple sclerosis; Six-minute walk; Gait analysis; Inertial measurement units; Wearable sensors; Biomechanics;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this work was to determine whether wearable inertial measurement units (IMUs) could detect gait improvements across different disability groups of people with Multiple Sclerosis (pwMS) by the six-minute walk test (6MWT) during a rehabilitation stay in a specialized rehabilitation center. Forty-six pwMS and 20 healthy controls (HC) were included in the study. They performed the 6MWT with two inertial measurement units (IMUs) placed on the feet. Thirty-two of the pwMS were retested at the end of the stay. PwMS were divided in a mild-disability and a moderate-disability group. The 6MWT was divided in six sections of 1 min each for technical analysis, and linear mixed models were used for statistical analyses. The comparison between the two disability groups and HC highlighted significant differences for each gait parameter (all p < 0.001). The crossing effect between the test–retest and the two disability groups showed greater improvement for the moderate-disability group. Finally, the gait parameter with the higher effect size, allowing the best differentiation between the disability groups, was the foot flat ratio (R2 = 0.53). Gait analyses from wearable sensors identified different evolutions of gait patterns during the 6MWT in pwMS with different physical disability. The measured effect of a short-time rehabilitation on gait with 6MWT was higher for pwMS with higher degree of disability. Using IMUs in a clinical setting allowed to identify significant changes in inter-stride gait patterns. Wearable sensors and key parameters have the potential as useful clinical tools for focusing on gait in pwMS.
引用
收藏
页码:3723 / 3734
页数:11
相关论文
共 212 条
[1]  
Filippi M(2018)Multiple sclerosis Nat Rev Dis Primers 4 43-1057
[2]  
Bar-Or A(2009)Contribution of impaired mobility and general symptoms to the burden of multiple sclerosis Adv Ther 26 1043-1452
[3]  
Piehl F(1983)Rating neurologic impairment in multiple sclerosis: an expanded disability status scale (EDSS) Neurology 33 1444-476
[4]  
Preziosa P(2012)Disability outcome measures in multiple sclerosis clinical trials: current status and future prospects Lancet Neurol 11 467-390
[5]  
Solari A(2008)Evaluation of the six-minute walk in multiple sclerosis subjects and healthy controls Mult Scler 14 383-631
[6]  
Vukusic S(2014)Responsiveness and clinically meaningful improvement, according to disability level, of five walking measures after rehabilitation in multiple sclerosis: a European multicenter study Neurorehabil Neural Repair 28 621-1411
[7]  
Rocca MA(2017)Technologies for advanced gait and balance assessments in people with multiple sclerosis Front Neurol 8 708-209
[8]  
Zwibel HL(2019)Beyond center-based testing: understanding and improving functioning with wearable technology in MS Mult Scler 25 1402-964
[9]  
Kurtzke JF(2018)Effects of rehabilitation on gait pattern at usual and fast speeds depend on walking impairment level in multiple sclerosis Int J MS Care 20 199-1537
[10]  
Cohen JA(2014)Body-worn sensors capture variability, but not decline, of gait and balance measures in multiple sclerosis over 18 months Gait Posture 39 958-900