Coronary bifurcation stent morphology in dual-source CT: validation with micro-CT

被引:0
作者
Hye-Joung Eom
Dong Hyun Yang
Young-Hak Kim
Jae-Hyung Roh
Jihoon Kweon
Soo-Jin Kang
Namkug Kim
Joon-Won Kang
Tae-Hwan Lim
机构
[1] University of Ulsan College of Medicine,Department of Radiology and Research Institute of Radiology, Asan Medical Center
[2] University of Ulsan College of Medicine,Department of Cardiology and Heart Institute, Asan Medical Center
来源
The International Journal of Cardiovascular Imaging | 2016年 / 32卷
关键词
CT; Micro CT; Bifurcation stent;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study is to analyze post-bifurcation coronary stent morphology in vitro using dual-source CT and validate those findings using micro-CT. Nine silicon coronary artery phantoms simulating main branch (MB) and side branch (SB) were prepared using a 3-D printer. After bifurcation stenting using Crush, Culotte, and T-stenting technique, in vitro CT imaging was conducted using both dual-source CT and micro-CT. Morphological change of the bifurcation stent including crushed segment and floating stent strut were evaluated. Dual-source CT was able to demonstrate morphologic changes of bifurcation stents and was comparable to micro-CT. In stents with Crush and T-stenting methods, crushed segment appeared denser and thicker than other stent parts and was located at MB side in all phantoms. Floating strut was observed in half of the phantoms with Crush technique and all phantoms with T-stenting. Parameters measured in both dual-source CT and micro-CT showed good correlation and high agreement (limits of agreement and correlation for length, perimeter and area, 0.3 ± 3.5, 0.5 ± 2.1 mm, and 0.0 ± 1.5 mm², r = 0.76, 0.92, and 0.91). The morphology of post-bifurcation stent on dual-source CT correlates well with that of micro-CT in the coronary artery phantom. Coronary CT angiography may be a feasible method for the evaluation of stent morphology in patients who underwent bifurcation stenting.
引用
收藏
页码:1659 / 1665
页数:6
相关论文
共 50 条
  • [41] Current Concepts for Experimental Micro-CT in Small Animals
    Bag, S.
    Schambach, S. J.
    Boll, H.
    Schilling, L.
    Groden, C.
    Brockmann, M. A.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (05): : 390 - 403
  • [42] Evaluation of microvascular anatomy by micro-CT
    Lerman, A
    Ritman, EL
    HERZ, 1999, 24 (07) : 531 - 533
  • [43] Visualization of 3D osteon morphology by synchrotron radiation micro-CT
    Cooper, D. M. L.
    Erickson, B.
    Peele, A. G.
    Hannah, K.
    Thomas, C. D. L.
    Clement, J. G.
    JOURNAL OF ANATOMY, 2011, 219 (04) : 481 - 489
  • [44] A study on the external and internal morphology of the mandibular first premolar using a Micro-CT
    Chun, Keyoung Jin
    Lee, Ho Jung
    ADVANCED NONDESTRUCTUVE EVALUATION I, PTS 1 AND 2, PROCEEDINGS, 2006, 321-323 : 1139 - 1144
  • [45] Evaluation of the Effect of a Tracheal Stent on Radiation Dose Distribution via Micro-CT Imaging
    Lin, Tao
    Ni, Xinye
    Gao, Liugang
    Sui, Jianfeng
    Xie, Kai
    Chang, Shuquan
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2019, 18 : 1 - 5
  • [46] Three-dimensional reconstruction of a cerebral stent using micro-CT for computational simulation
    Ohta, Makoto
    He, Chuan
    Nakayama, Toshio
    Takahashi, Akipa
    Ruefenacht, Daniel A.
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2008, 19 (03) : 313 - 318
  • [47] 3D Observation of Expansion of Stent and Elastic Recoil using Micro-CT
    Mori, Futoshi
    Nakayama, Toshio
    Matsuzawa, Teruo
    Ohta, Makoto
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 6, 2009, 25 : 235 - +
  • [48] Validation of a micro-CT technique for measuring volumetric wear in retrieved acetabular liners
    Bowden, AE
    Kurtz, SM
    Edidin, AA
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 75B (01) : 205 - 209
  • [49] Multicenter Evaluation of Coronary Dual-Source CT Angiography in Patients with Intermediate Risk of Coronary Artery Stenoses (MEDIC): Study design and rationale
    Marwan, Mohamed
    Hausleiter, Joerg
    Abbara, Suhny
    Hoffmann, Udo
    Becker, Christoph
    Ovrehus, Kristian
    Ropers, Dieter
    Bathina, Ravi
    Berman, Dan
    Anders, Katharina
    Uder, Michael
    Meave, Aloha
    Alexanderson, Erick
    Achenbach, Stephan
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (03) : 183 - 188
  • [50] Multiscale dual energy micro-CT for imaging using iodinated and gold nanoparticles
    Holbrook, M.
    Clark, D. P.
    Badea, C. T.