Coronary bifurcation stent morphology in dual-source CT: validation with micro-CT

被引:0
|
作者
Hye-Joung Eom
Dong Hyun Yang
Young-Hak Kim
Jae-Hyung Roh
Jihoon Kweon
Soo-Jin Kang
Namkug Kim
Joon-Won Kang
Tae-Hwan Lim
机构
[1] University of Ulsan College of Medicine,Department of Radiology and Research Institute of Radiology, Asan Medical Center
[2] University of Ulsan College of Medicine,Department of Cardiology and Heart Institute, Asan Medical Center
来源
The International Journal of Cardiovascular Imaging | 2016年 / 32卷
关键词
CT; Micro CT; Bifurcation stent;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study is to analyze post-bifurcation coronary stent morphology in vitro using dual-source CT and validate those findings using micro-CT. Nine silicon coronary artery phantoms simulating main branch (MB) and side branch (SB) were prepared using a 3-D printer. After bifurcation stenting using Crush, Culotte, and T-stenting technique, in vitro CT imaging was conducted using both dual-source CT and micro-CT. Morphological change of the bifurcation stent including crushed segment and floating stent strut were evaluated. Dual-source CT was able to demonstrate morphologic changes of bifurcation stents and was comparable to micro-CT. In stents with Crush and T-stenting methods, crushed segment appeared denser and thicker than other stent parts and was located at MB side in all phantoms. Floating strut was observed in half of the phantoms with Crush technique and all phantoms with T-stenting. Parameters measured in both dual-source CT and micro-CT showed good correlation and high agreement (limits of agreement and correlation for length, perimeter and area, 0.3 ± 3.5, 0.5 ± 2.1 mm, and 0.0 ± 1.5 mm², r = 0.76, 0.92, and 0.91). The morphology of post-bifurcation stent on dual-source CT correlates well with that of micro-CT in the coronary artery phantom. Coronary CT angiography may be a feasible method for the evaluation of stent morphology in patients who underwent bifurcation stenting.
引用
收藏
页码:1659 / 1665
页数:6
相关论文
共 50 条
  • [21] Micro-CT and optical microscopy imagistic investigations of root canal morphology
    Craciunescu, Emanuela Lidia
    Boariu, Marius
    Ionita, Ciprian
    Pop, Daniela Maria
    Sinescu, Cosmin
    Rominu, Mihai
    Negrutiu, Meda Lavinia
    ROMANIAN JOURNAL OF MORPHOLOGY AND EMBRYOLOGY, 2016, 57 (03) : 1069 - 1073
  • [22] Hemodynamics and In-stent Restenosis: Micro-CT Images, Histology, and Computer Simulations
    Morlacchi, Stefano
    Keller, Brandis
    Arcangeli, Patrizia
    Balzan, Marta
    Migliavacca, Francesco
    Dubini, Gabriele
    Gunn, Julian
    Arnold, Nadine
    Narracott, Andrew
    Evans, David
    Lawford, Patricia
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (10) : 2615 - 2626
  • [23] Hemodynamics and In-stent Restenosis: Micro-CT Images, Histology, and Computer Simulations
    Stefano Morlacchi
    Brandis Keller
    Patrizia Arcangeli
    Marta Balzan
    Francesco Migliavacca
    Gabriele Dubini
    Julian Gunn
    Nadine Arnold
    Andrew Narracott
    David Evans
    Patricia Lawford
    Annals of Biomedical Engineering, 2011, 39 : 2615 - 2626
  • [24] Validation of finite element models of liver tissue using Micro-CT
    Shi, Hongjian
    Farag, Aly A.
    Fahmi, Rachid
    Chen, Dongqing
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (03) : 978 - 984
  • [25] A preliminary study on a dual-modality OPT/micro-CT system
    Yang, Yujie
    Dong, Di
    Shi, Liangliang
    Wang, Jun
    Hui, Hui
    Yang, Xin
    Tian, Jie
    IMAGING, MANIPULATION, AND ANALYSIS OF BIOMOLECULES, CELLS, AND TISSUES XIII, 2015, 9328
  • [26] Dual Energy CT Imaging in Cone-Beam Micro-CT for Improved Attenuation Coefficient Measurement
    唐智伟
    胡广书
    TsinghuaScienceandTechnology, 2011, 16 (04) : 352 - 357
  • [27] E15.5 Mouse Embryo Micro-CT Using a Bruker Skyscan 1172 Micro-CT
    Astanina, Elena
    Petrillo, Sara
    Genova, Tullio
    Mussano, Federico
    Bussolino, Federico
    BIO-PROTOCOL, 2023, 13 (09):
  • [28] Implementation of interior micro-CT on a carbon nanotube dynamic micro-CT scanner for lower radiation dose
    Gong, Hao
    Lu, Jianping
    Zhou, Otto
    Cao, Guohua
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [29] Dual source hybrid spectral micro-CT using an energy-integrating and a photon-counting detector
    Holbrook, M. D.
    Clark, D. P.
    Badea, C. T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (20)
  • [30] Compensation of mechanical inaccuracies in micro-CT and nano-CT
    Sasov, Alexander
    Liu, Xuan
    Salmon, Phil L.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VI, 2008, 7078