Coronary bifurcation stent morphology in dual-source CT: validation with micro-CT

被引:0
|
作者
Hye-Joung Eom
Dong Hyun Yang
Young-Hak Kim
Jae-Hyung Roh
Jihoon Kweon
Soo-Jin Kang
Namkug Kim
Joon-Won Kang
Tae-Hwan Lim
机构
[1] University of Ulsan College of Medicine,Department of Radiology and Research Institute of Radiology, Asan Medical Center
[2] University of Ulsan College of Medicine,Department of Cardiology and Heart Institute, Asan Medical Center
来源
The International Journal of Cardiovascular Imaging | 2016年 / 32卷
关键词
CT; Micro CT; Bifurcation stent;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study is to analyze post-bifurcation coronary stent morphology in vitro using dual-source CT and validate those findings using micro-CT. Nine silicon coronary artery phantoms simulating main branch (MB) and side branch (SB) were prepared using a 3-D printer. After bifurcation stenting using Crush, Culotte, and T-stenting technique, in vitro CT imaging was conducted using both dual-source CT and micro-CT. Morphological change of the bifurcation stent including crushed segment and floating stent strut were evaluated. Dual-source CT was able to demonstrate morphologic changes of bifurcation stents and was comparable to micro-CT. In stents with Crush and T-stenting methods, crushed segment appeared denser and thicker than other stent parts and was located at MB side in all phantoms. Floating strut was observed in half of the phantoms with Crush technique and all phantoms with T-stenting. Parameters measured in both dual-source CT and micro-CT showed good correlation and high agreement (limits of agreement and correlation for length, perimeter and area, 0.3 ± 3.5, 0.5 ± 2.1 mm, and 0.0 ± 1.5 mm², r = 0.76, 0.92, and 0.91). The morphology of post-bifurcation stent on dual-source CT correlates well with that of micro-CT in the coronary artery phantom. Coronary CT angiography may be a feasible method for the evaluation of stent morphology in patients who underwent bifurcation stenting.
引用
收藏
页码:1659 / 1665
页数:6
相关论文
共 50 条
  • [1] Coronary bifurcation stent morphology in dual-source CT: validation with micro-CT
    Eom, Hye-Joung
    Yang, Dong Hyun
    Kim, Young-Hak
    Roh, Jae-Hyung
    Kweon, Jihoon
    Kang, Soo-Jin
    Kim, Namkug
    Kang, Joon-Won
    Lim, Tae-Hwan
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (11) : 1659 - 1665
  • [2] HELICAL DUAL SOURCE CONE-BEAM MICRO-CT
    Johnston, Samuel M.
    Johnson, G. Allan
    Badea, Cristian T.
    2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI), 2014, : 177 - 180
  • [3] Radiation Dose at Coronary CT Angiography: Second-Generation Dual-Source CT Versus Single-Source 64-MDCT and First-Generation Dual-Source CT
    Fink, Christian
    Krissak, Radko
    Henzler, Thomas
    Lechel, Ursula
    Brix, Gunnar
    Takx, Richard A. P.
    Nance, John W.
    Abro, Joseph A.
    Schoenberg, Stefan O.
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (05) : W550 - W557
  • [4] High pitch third generation dual-source CT: Coronary and cardiac visualization on routine chest CT
    Sandfort, Veit
    Ahlman, Mark A.
    Jones, Elizabeth C.
    Selwaness, Mariana
    Chen, Marcus Y.
    Folio, Les R.
    Bluemke, David A.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (04) : 282 - 288
  • [5] Thoracic applications of dual-source CT technology
    Boroto, Kahimano
    Remy-Jardin, Martine
    Flohr, Thomas
    Faivre, Jean-Baptiste
    Pansini, Vittorio
    Tacelli, Nunzia
    Schmidt, Bernhard
    Gorgos, Andrei
    Remy, Jacques
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) : 375 - 384
  • [6] Noise Reduction in Dual-Source CT Scanning
    Petersilka, M.
    Krauss, B.
    Stierstorfer, K.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [7] A comparison of sampling strategies for dual energy micro-CT
    Guo, Xiaolian
    Johnston, Samuel M.
    Johnson, G. Allan
    Badea, Cristian T.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [8] The effect of scatter correction on dual energy micro-CT
    Clark, D.
    Johnston, S. M.
    Johnson, G. A.
    Badea, C. T.
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [9] Dual-source CT coronary angiography. Diagnostic accuracy without the use of B blockers
    Saad, Mohammad Ahmad M.
    Azer, Hany Younan
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2011, 42 (3-4) : 281 - 287
  • [10] Micro-CT as a guide for clinical CT development
    Ritman, Erik L.
    Eaker, Diane R.
    Jorgensen, Steven M.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318