Time-resolved ultra-small-angle X-ray scattering beamline (BL10U1) at SSRF

被引:0
作者
Wen-Qiang Hua
Chun-Ming Yang
Ping Zhou
Feng Tian
Jin-You Lin
Yu-Zhu Wang
Xiao-Yun Li
Xia-Ran Miao
Chun-Xia Hong
Qiu-Shi Huang
Xin-Tong Zhao
Yong-Feng Men
Jie Wang
Xing-Yu Gao
Xiu-Hong Li
机构
[1] Chinese Academy of Sciences,Shanghai Synchrotron Radiation Facility, Shanghai Advanced Research Institute
[2] Tongji University,Key Laboratory of Advanced Micro Structural Materials, MOE, Institute of Precision Optical Engineering, School of Physics Science and Engineering
[3] Chinese Academy of Sciences,State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry
来源
Nuclear Science and Techniques | 2024年 / 35卷
关键词
Synchrotron radiation; Ultra-small-angle X-ray scattering; Micro small-angle X-ray scattering; USAXS; Time resolved; μSAXS;
D O I
暂无
中图分类号
学科分类号
摘要
The construction of a new beamline, BL10U1, was completed at the Shanghai synchrotron radiation facility in 2020. This multipurpose beamline was designed to provide X-ray scattering techniques such as ultra-small-angle X-ray scattering (USAXS), small-angle X-ray scattering (SAXS), wide-angle X-ray scattering, and microfocus SAXS (μSAXS) for a broad user community. To realize fast time-resolved USAXS experiments, the beamline adopted an in-vacuum undulator with a total length of 1.6 m as the photon source. An in-house cryogenic-cooled double multilayer monochromator was installed to deliver a photon flux of approximately 1013 photons/s at a photon energy of 10 keV. The three-year successful operation of this beamline demonstrated that the monochromator operated smoothly, as expected. BL10U1 has three end stations in succession: USAXS end station, μSAXS end station, and end station for industrial applications. The minimum scattering vector q ~ 0.0042 nm−1 at 10 keV can be achieved at the USAXS end station equipped with a 28 m-long and 1.8 m-diameter vacuum flight tube. At the μSAXS end station, a beam spot of less than 10 × 8 μm was achieved for micro-SAXS experiments. In contrast, in situ experimental instruments up to 5 m high and 8 m wide can be mounted at the industrial application end station, which offers industrial scientists the opportunity to use their large industrial equipment. BL10U1 opens up a new capability to investigate phenomena such as non-equilibrium and dynamic processes of materials with a wide length scale from angstroms to micrometers with millisecond time resolution. In this paper, we also report beamline design considerations and commissioning results.
引用
收藏
相关论文
共 85 条
  • [1] Tian F(2015)Small angle X-ray scattering beamline at SSRF Nucl. Sci. Tech. 26 030101-1953
  • [2] Li XH(2022)First commissioning results of the coherent scattering and imaging endstation at the Shanghai soft X-ray free-electron laser facility Nucl. Sci. Tech. 33 114-111
  • [3] Wang YZ(2021)Measurement of the coherent beam properties at the CoSAXS beamline J. Synchrotron Rad. 28 1948-121
  • [4] Fan JD(2020)BL19U2: small-angle X-ray scattering beamline for biological macromolecules in solution at SSRF Nucl. Sci. Tech. 31 117-141
  • [5] Tong YJ(2022)Performance of the time-resolved ultra-small-angle X-ray scattering beamline with the extremely brilliant source J. Appl. Cryst. 55 98-1524
  • [6] Nie YG(2016)A novel heating area design of temperature-jump microfluidic chip for synchrotron radiation solution X-ray scattering Nucl. Sci. Tech. 27 92-653
  • [7] Kahnt M(2010)A small/wide-angle X-ray scattering instrument for structural characterization of air-liquid interfaces, thin films and bulk specimens J. Appl. Cryst. 43 110-1432
  • [8] Klementiev K(2014)A small-angle X-ray scattering station at Beijing synchrotron radiation facility Instrum. Sci. Technol. 42 128-664
  • [9] Haghighat V(2016)High-throughput and automated SAXS/USAXS experiment for industrial use at BL19B2 in SPring-8 AIP Conf. Proc. 1741 030003-10
  • [10] Li YW(2018)A multipurpose instrument for time-resolved ultra-small-angle and coherent X-ray scattering J. Appl. Cryst. 51 1511-A53