Tracheotomy for a foreign body in the larynx

被引:10
作者
Chrcanovic B.R. [1 ,2 ]
Souza L.N. [3 ]
机构
[1] João XXIII Hospital, Belo Horizonte Minas Gerais
[2] Belo Horizonte Minas Gerais 30380-090, Av. Raja Gabaglia
[3] Belo Horizonte Minas Gerais 30110-100, Av. do Contorno, 4747/705, Serra
关键词
Aspiration; Dental prosthesis; Larynx; Tracheotomy;
D O I
10.1007/s10006-009-0148-6
中图分类号
学科分类号
摘要
Introduction: In the normal population, inadvertently swallowed foreign objects enter the gastrointestinal tract more frequently than the tracheobronchial tree. There is a typical patient population that is at higher risk for aspiration. Discussion: Sequelae may range from relatively benign partial obstruction to the immediately life-threatening total airway obstruction. Foreign objects lodged in the upper aspect of the trachea may be retrieved with simple instrumentation. Conclusion: Some cases may complicate and may require direct access through a tracheotomy, as the case shown in this paper. © pringer-Verlag 2009.
引用
收藏
页码:55 / 58
页数:3
相关论文
共 27 条
[1]  
Haugen R.K., The cafe coronary: Sudden death in restaurants, JAMA, 186, pp. 142-143, (1963)
[2]  
Fields Jr. R.T., Schow S.R., Aspiration and ingestion of foreign bodies in oral and maxillofacial surgery: A review of the literature and report of five cases, J Oral Maxillofac Surg, 56, pp. 1091-1098, (1998)
[3]  
McArthur D.R., Taylor D.F., A determination of the minimum radiopacification necessary for radiographic detection of an aspirated or swallowed object, Oral Surg Oral Med Oral Pathol, 39, pp. 329-338, (1975)
[4]  
Daly S.M., Weinberg B., Murphy R.J., Shugar J.M., Rose J.S., Unrecognized aspiration of an oropharyngeal airway, Pediatr Radiol, 13, pp. 227-228, (1983)
[5]  
Newton J.P., Abel R.W., Lloyd C.H., Yemm R., The use of computed tomography in the detection of radiolucent denture base material in the chest, J Oral Rehabil, 14, pp. 193-202, (1987)
[6]  
Youngs R.P., Gatland D., Brookes J., Swallowed radiolucent dental prostheses: Risk of extraluminal oesophageal perforation, J Laryngol Otol, 102, pp. 71-73, (1988)
[7]  
Mohnssen S.R., Greggs D., Iatrogenic aspiration of components of respiratory care equipment, Chest, 103, pp. 964-965, (1993)
[8]  
Mucci B., Eyre T., Soft tissue neck radiography for displaced dental prostheses, Clin Radiol, 47, pp. 424-425, (1993)
[9]  
Morris A.J., Jennings C.N., A nose stud retainer clip lost within the nasal cavity discovered on dental radiographs, Dent Update, 21, pp. 70-72, (1994)
[10]  
Versichelen L., Herregods L., Donadoni R., Et al., Anesthesia for foreign bodies in the trachea-bronchial tree in children, Acta Anaesthesiol Belg, 36, (1985)