Texture analysis with a new method in which the region of interest is segmented into multiple layers for radiofrequency amplitude histogram analysis of fibrous rat livers

被引:4
作者
Fujii Y. [1 ]
Taniguchi N. [1 ]
Takano R. [2 ]
Wang Y. [1 ]
Shigeta K. [1 ]
Omoto K. [1 ]
Ono T. [1 ]
Satoh I. [1 ]
Itoh K. [1 ]
机构
[1] Department of Clinical Laboratory Medicine, Jichi Medical School, Kawachi-gun, Tochigi 329-0498, Minamikawachi-machi
[2] Department of Nephrology, Jichi Medical School, Kawachi-gun, Tochigi 329-0498, Minamikawachi-machi
关键词
Fibrous liver; Histogram; Radiofrequency signal; Rat; Tissue characterization; Ultrasound;
D O I
10.1007/s10396-003-0004-5
中图分类号
学科分类号
摘要
Purpose. The aim of this study was to estimate the severity of fibrosis without a biopsy. Methods. The signal-to-noise ratio (SNR), skewness, and kurtosis were measured using a 10-MHz transducer with the texture analysis in conjunction with an alternative method for evaluating fibrous rat livers. This method segments the region of interest (ROI) into multiple layers (sub-ROIs). In each sub-ROI of a homogeneous medium, the histogram of enveloped amplitude of radiofrequency (RF) backscattered echoes resembles a Rayleigh distribution. In theory, SNR, skewness, and kurtosis for Rayleigh statistics are constant and independent of the mean scattering intensity, which is enhanced by such undesirable effects as tissue attenuation, beam diffraction, and incident waveforms. Thus, these values, which are averages of the corresponding sub-ROI values, constitute an unbiased estimator. All fibrous liver specimens were induced using the dimethylnitrosamine method. Fiber content was estimated quantitatively as the fibrosis index by computer processing of pathological images obtained by light microscopy. Results. The SNR, skewness and kurtosis, expressed as averages of corresponding values from each sub-ROI, correlated closely with the fibrosis index. Conclusion. These results make it possible to predict the severity of liver fibrosis from data obtained without resorting to biopsy. The data, obtained from our earlier study on rats, may be used to evaluate human hepatitis quantitatively by measuring these three values. The method may make it possible to estimate the degree of severity of chronic liver disease noninvasively. © The Japan Society of Ultrasonics in Medicine 2004.
引用
收藏
页码:13 / 20
页数:7
相关论文
共 30 条
  • [1] Bamber J.C., Hill C.R., King J.A., Acoustic properties of normal and cancerous human liver. II. Dependence on tissue structure, Ultrasound Med Biol, 7, pp. 135-144, (1981)
  • [2] Nishimura N., Non-invasive quantitative assessment of hepatic fatty change by the hepatic ultrasound velocity and attenuation coefficient, Jpn J Med Ultrasonics, 16, pp. 151-160, (1989)
  • [3] Maklad N.F., Ophir J., Balsara V., Attenuation of ultrasound in normal liver and diffuse liver disease in vivo, Ultrason Imaging, 6, pp. 117-125, (1984)
  • [4] Garra B.S., Insana M.F., Shawker T.H., Et al., Quantitative estimation of liver attenuation and echogenicity: Normal state versus diffuse liver disease, Radiology, 162, pp. 61-67, (1987)
  • [5] Wang Y., Itoh K., Taniguchi N., Et al., Ultrasonic tissue characterization by texture analysis using normal and pathologic livers and a reference phantom: Relationship between depth range, scanning plane, probe frequency, and magnification rate in the ultrasound image, J Med Ultrasonics, 24, pp. 861-872, (1997)
  • [6] Wang Y., Itoh K., Taniguchi N., Et al., Ultrasonic tissue characterization by texture analysis with co-occurrence matrix method using ultrasonography and CT imaging, J Med Ultrasonics, 26, pp. 825-37, (1999)
  • [7] Tsao J.W., Itoh T., Konishi T., A new method for amplitude histogram analysis in B-mode ultrasonography, Jpn J Med Ultrasonics, 14, 2 SUPPL., pp. 171-172, (1987)
  • [8] Tsao J.W., Itoh T., Konishi T., Formulation and statistical evaluation for parametric histogram variations in B-mode ultrasonography, Jpn J Med Ultrasonics, 16, pp. 1-12, (1989)
  • [9] Fujii Y., Taniguchi N., Shigeta K., Et al., Clinical application of the new method for amplitude analysis in B-mode ultrasonography in the diffuse hepatic disease, J Med Ultrasonics, 27, SUPPL., (2000)
  • [10] Fujii Y., Taniguchi N., Wang Y., Et al., Clinical application of a new method that segments the region of interest into multiple layers for RF amplitude histogram analysis in the cirrhotic liver, J Med Ultrasonics, 28, (2001)