Evaluation of Thyroid Lesions by Fine Needle Aspiration Cytology According to Bethesda System

被引:0
作者
Disha Jain
Rashmi Sharma
Geeta Pachori
Tushar Bayla
机构
[1] JLN Medical College,Department of Pathology
[2] Bhilwada Medical College,Department of Biochemistry
来源
Indian Journal of Otolaryngology and Head & Neck Surgery | 2023年 / 75卷
关键词
Bethesda; FNAC; Thyroid; Diagnostic accuracy;
D O I
暂无
中图分类号
学科分类号
摘要
Aim To study cytology of various Thyroid lesions based on Bethesda system and to evaluate diagnostic accuracy of cytology by comparing it with histomorphological diagnosis whenever available. Materials and method In this study Fine needle aspiration cytology of 330 patients of clinically palpable thyroid were evaluated from June 2019 to December 2021 and categorised according to TBSRTC. 38 patients underwent surgical management in our hospital. Sensitivity, specificity, positive predictive value, negative predictive value reported under bethesda system were obtained by comparing the cytological and histopathological diagnosis where ever possible. Result The distribution of various categories from 330 evaluated thyroid nodules was as follows: 2.73% Non Diagnostic, 83.03% Benign, 0% Atypia of undetermined significance, 9.70% FN, 0.61% Suspicious for malignancy and 3.94% malignant. Sensitivity, specificity, positive predictive value, negative predictive value was 100, 60, 94.29 and 100% respectively. The diagnostic accuracy was calculated to be 94.73%. Conclusion There is a clearcut distinction between the two ends of the spectrum of non-neoplastic and neoplastic lesions of thyroid. Diagnostic accuracy of Bethesda system for reporting cytopathology for better clinical management is proven by the present study.
引用
收藏
页码:457 / 462
页数:5
相关论文
共 57 条
[1]  
Song JY(2012)Reclassifying formerly indeterminate thyroid FNAs using the Bethesda system reduces the number of inconclusive cases Acta Cytologica 56 122-29
[2]  
Soderstorm N(1952)Puncture of goiters for aspiration biopsy Acta Med Scand 144 237-244
[3]  
Gerhard R(2007)Inter-and intraobserver reproducibility of thyroid fine needle aspiration cytology: an analysis of discrepant cases Cytopathology 18 105-111
[4]  
da Cunha SG(2006)Reporting thyroid fine-needle aspiration: literature review and a proposal Diagn Cytopathol 34 67-76
[5]  
Wang HH(2009)NCI thyroid FNA state of the science conference. The Bethesda system for reporting thyroid cytopathology Am J Clin Pathol 132 658-65
[6]  
Cibas ES(2019)Diagnostic efficacy of ultrasound-guided fine needle aspiration combined with the bethesda system of reporting J Cytol 36 101-105
[7]  
Ali SZ(2017)The 2017 Bethesda system for reporting thyroid cytopathology J Am Soc Cytopathol 27 1341-1346
[8]  
Kumari KA(2009)Role of fine needle aspiration cytology in diagnosis and -management of thyroid lesions: a study on 434 patients J Cytol 25 13-16
[9]  
Jadhav PD(2018)Reproducibility of the Bethesda system for reporting thyroid cytopathology: a retrospective analysis of 107 Patients J Cytol 35 33-6
[10]  
Prasad C(2018)A comparative study between conventional method and the Bethesda system for repoting thyroid cytopathology (TBSRTC) Int J Res Med Sci 6 2662-6