Management of Mandibular Angle Fractures Using Single Y-Shaped Titanium Miniplate at the Superior Border: A Prospective Clinical Study

被引:0
作者
Sunaina Singla
Ravi Narula
Parnika Kuthiala
Ajay Mittal
Hirdepal Singh Brar
Mukesh Singla
机构
[1] Guru Nanak Dev Dental College & Research Institute,Department of Oral and Maxillofacial Surgery
[2] Shaheed Kartar Singh Sarabha Dental College & Hospital,Department of Oral and Maxillofacial Surgery
[3] Mukesh’s Dent-o-Care,undefined
来源
Indian Journal of Otolaryngology and Head & Neck Surgery | 2022年 / 74卷
关键词
Mandibular angle fracture; Y-shaped titanium miniplate; Superior border; Occlusion; Pain; Neurosensory deficit;
D O I
暂无
中图分类号
学科分类号
摘要
Treatment of angle fractures remains controversial. The various techniques documented for the treatment are: wire osteosynthesis, one miniplate at superior border (2.0 mm), a single plate on inferior border (2.3 or 2.7 mm) along with tension band in the form of arch bar at the upper border, 2 miniplates (1 at superior border and 1 at inferior border), 3-D strut plates or lag screw. To evaluate the efficacy of single Y-shaped titanium miniplate at the superior border in the management of mandibular angle fractures. Total of 15 healthy adult patients reporting to the department of Oral and Maxillofacial Surgery for the treatment of mandibular angle fractures was randomly selected. All the cases were assessed clinically at 1st post-operative day, 1st, 3rd, 6th and 12th week post-operatively for pain, status of occlusion, neurosensory deficit and postoperative hard & soft tissue healing. Radiographic assessment was also done at 1st postoperative day, 6 weeks and 12 weeks. Postoperative pain, infection, wound dehiscence, neurosensory deficit were not evident during the follow- up periods. Radiographically, the fracture reduction was good and plate fracture was not seen in any case. Y- shaped titanium miniplate is an effective method in the management of the mandibular angle fractures and provided satisfactory results.
引用
收藏
页码:4495 / 4499
页数:4
相关论文
共 48 条
  • [1] Al-Moraissi EA(2015)One miniplate compared with two in the fixation of isolated fractures of the mandibular angle Br J Oral MaxillofacSurg 53 690-698
  • [2] Melek LN(2015)Evaluation of the 3-dimensional threadlock plate in the management of mandibular angle fractures: a clinical and radiographic study Tanta Dent J 12 140-148
  • [3] El Mahallawy AS(2015)Early and delayed complications associated with three dimensional (3-D) miniplates in mandibular fracture management: a prospective study Bhavnagar Univ J Dent 5 20-24
  • [4] Sharara AA(2012)Titanium three dimensional miniplate versus conventional titanium miniplate in fixation of anterior mandibular fractures Life Sci J 9 1006-1010
  • [5] Sahni V(2011)Three-dimensional miniplate fixation in mandibular angle fractures Indian J Multidiscip Dent 1 89-92
  • [6] Garg S(2013)Conventional 2.0 mm miniplates versus 3-D plates in mandibular fractures Ann MaxillofacSurg 3 154-159
  • [7] Kaur S(2014)Biomechanical evaluation of a new design titanium miniplate for the treatment of mandibular angle fractures Int J Oral MaxillofacSurg 43 841-845
  • [8] Khalifa ME(2017)Simple percutaneous transbuccal approach for management of mandibular angular fracture J CraniofacSurg 00 1-3
  • [9] El-Hawary HE(2016)Management of mandibular angle fractures by two conventional 2.0-mm miniplates: a retrospective study of 389 patients Craniomaxillofac Trauma Reconstr 9 206-210
  • [10] Hussein MM(2008)Analysis of 115 mandibular angle fractures’ J Oral MaxillofacSurg 66 73-78