Parallel imaging: Is GRAPPA a useful acquisition tool for MR imaging intended for volumetric brain analysis?

被引:11
作者
Lindholm T.L. [1 ,2 ]
Botes L. [1 ,2 ]
Engman E.-L. [2 ]
Frank A. [1 ,2 ]
Jonsson T. [1 ,2 ]
Svensson L. [1 ,2 ]
Julin P. [2 ,3 ,4 ]
机构
[1] Department of Diagnostic Medical Physics, Karolinska University Hospital Huddinge, Stockholm
[2] SMILE Image Laboratory, Karolinska Institute, Stockholm
[3] Astra Zeneca Research and Development, Södertälje
[4] Department of Rehabilitation Medicine, Danderyd Hospital, Karolinska Institute, Stockholm
关键词
Cerebral Spinal Fluid; Parallel Imaging; Acceleration Factor; Mild Cognitively Impaired Patient; Young Healthy Volunteer;
D O I
10.1186/1471-2342-9-15
中图分类号
学科分类号
摘要
Background: The work presented here investigates parallel imaging applied to T1-weighted high resolution imaging for use in longitudinal volumetric clinical studies involving Alzheimer's disease (AD) and Mild Cognitive Impairment (MCI) patients. This was in an effort to shorten acquisition times to minimise the risk of motion artefacts caused by patient discomfort and disorientation. The principle question is, "Can parallel imaging be used to acquire images at 1.5 T of sufficient quality to allow volumetric analysis of patient brains?" Methods: Optimisation studies were performed on a young healthy volunteer and the selected protocol (including the use of two different parallel imaging acceleration factors) was then tested on a cohort of 15 elderly volunteers including MCI and AD patients. In addition to automatic brain segmentation, hippocampus volumes were manually outlined and measured in all patients. The 15 patients were scanned on a second occasion approximately one week later using the same protocol and evaluated in the same manner to test repeatability of measurement using images acquired with the GRAPPA parallel imaging technique applied to the MPRAGE sequence. Results: Intraclass correlation tests show that almost perfect agreement between repeated measurements of both segmented brain parenchyma fraction and regional measurement of hippocampi. The protocol is suitable for both global and regional volumetric measurement dementia patients. Conclusion: In summary, these results indicate that parallel imaging can be used without detrimental effect to brain tissue segmentation and volumetric measurement and should be considered for both clinical and research studies where longitudinal measurements of brain tissue volumes are of interest. © 2009 Lindholm et al; licensee BioMed Central Ltd.
引用
收藏
相关论文
共 50 条
[41]   A tour of accelerated parallel MR imaging from a linear systems perspective [J].
Hoge, WS ;
Brooks, DH ;
Madore, B ;
Kyriakos, WE .
CONCEPTS IN MAGNETIC RESONANCE PART A, 2005, 27A (01) :17-37
[42]   UNIVERSAL GENERATIVE MODELING FOR CALIBRATION-FREE PARALLEL MR IMAGING [J].
Zhu, Wanqing ;
Guan, Bing ;
Wang, Shanshan ;
Zhang, Minghui ;
Liu, Qiegen .
2022 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (IEEE ISBI 2022), 2022,
[43]   Exploiting sparsity to accelerate noncontrast MR angiography in the context of parallel imaging [J].
Storey, Pippa ;
Otazo, Ricardo ;
Lim, Ruth P. ;
Kim, Sooah ;
Fleysher, Lazar ;
Oesingmann, Niels ;
Lee, Vivian S. ;
Sodickson, Daniel K. .
MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (05) :1391-1400
[44]   MR imaging for shoulder diseases: Effect of compressed sensing and deep learning reconstruction on examination time and imaging quality compared with that of parallel imaging [J].
Obama, Yuki ;
Ohno, Yoshiharu ;
Yamamoto, Kaori ;
Ikedo, Masato ;
Yui, Masao ;
Hanamatsu, Satomu ;
Ueda, Takahiro ;
Ikeda, Hirotaka ;
Murayama, Kazuhiro ;
Toyama, Hiroshi .
MAGNETIC RESONANCE IMAGING, 2022, 94 :56-63
[45]   Thin-section diffusion-weighted magnetic resonance imaging of the brain with parallel imaging [J].
Oner, A. Y. ;
Celik, H. ;
Tali, T. ;
Akpek, S. ;
Tokgoz, N. .
ACTA RADIOLOGICA, 2007, 48 (04) :456-463
[46]   Accelerated MR cell size imaging through parallel acquisition technique (PAT) and simultaneous multi-slice (SMS) with local principal component analysis (LPCA) enhancement [J].
Wu, Tianxiong ;
Sun, Jiayu ;
Wang, Zhihao ;
Tan, Jia ;
Tang, Xianqing ;
Xiong, Deng ;
Feiweier, Thorsten ;
Gong, Qiyong ;
Xing, Haoyang ;
Wu, Min .
MAGNETIC RESONANCE IMAGING, 2025, 117
[47]   Quantitative myocardial perfusion imaging using different autocalibrated parallel acquisition techniques [J].
Weber, Stefan ;
Kronfeld, Andrea ;
Kunz, R. Peter ;
Muennemann, Kerstin ;
Horstick, Georg ;
Kreitner, Karl-Friedrich ;
Schreiber, Wolfgang G. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (01) :51-59
[48]   Novel Reconstruction Method for Three-Dimensional Axial Continuously Moving Table Whole-Body Magnetic Resonance Imaging Featuring Autocalibrated Parallel Imaging GRAPPA [J].
Zenge, Michael O. ;
Ladd, Mark E. ;
Quick, Harald H. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (04) :867-873
[49]   GRAPPA-based susceptibility-weighted imaging of normal volunteers and patients with brain tumor at 7 T [J].
Lupo, Janine M. ;
Banerjee, Suchandrima ;
Hammond, Kathryn E. ;
Kelley, Douglas A. C. ;
Xu, Duan ;
Chang, Susan M. ;
Vigneron, Daniel B. ;
Majumdar, Sharmila ;
Nelson, Sarah J. .
MAGNETIC RESONANCE IMAGING, 2009, 27 (04) :480-488
[50]   A Prior Learning Network for Joint Image and Sensitivity Estimation in Parallel MR Imaging [J].
Meng, Nan ;
Yang, Yan ;
Xu, Zongben ;
Sun, Jian .
MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2019, PT IV, 2019, 11767 :732-740