Parallel imaging: Is GRAPPA a useful acquisition tool for MR imaging intended for volumetric brain analysis?

被引:11
|
作者
Lindholm T.L. [1 ,2 ]
Botes L. [1 ,2 ]
Engman E.-L. [2 ]
Frank A. [1 ,2 ]
Jonsson T. [1 ,2 ]
Svensson L. [1 ,2 ]
Julin P. [2 ,3 ,4 ]
机构
[1] Department of Diagnostic Medical Physics, Karolinska University Hospital Huddinge, Stockholm
[2] SMILE Image Laboratory, Karolinska Institute, Stockholm
[3] Astra Zeneca Research and Development, Södertälje
[4] Department of Rehabilitation Medicine, Danderyd Hospital, Karolinska Institute, Stockholm
关键词
Cerebral Spinal Fluid; Parallel Imaging; Acceleration Factor; Mild Cognitively Impaired Patient; Young Healthy Volunteer;
D O I
10.1186/1471-2342-9-15
中图分类号
学科分类号
摘要
Background: The work presented here investigates parallel imaging applied to T1-weighted high resolution imaging for use in longitudinal volumetric clinical studies involving Alzheimer's disease (AD) and Mild Cognitive Impairment (MCI) patients. This was in an effort to shorten acquisition times to minimise the risk of motion artefacts caused by patient discomfort and disorientation. The principle question is, "Can parallel imaging be used to acquire images at 1.5 T of sufficient quality to allow volumetric analysis of patient brains?" Methods: Optimisation studies were performed on a young healthy volunteer and the selected protocol (including the use of two different parallel imaging acceleration factors) was then tested on a cohort of 15 elderly volunteers including MCI and AD patients. In addition to automatic brain segmentation, hippocampus volumes were manually outlined and measured in all patients. The 15 patients were scanned on a second occasion approximately one week later using the same protocol and evaluated in the same manner to test repeatability of measurement using images acquired with the GRAPPA parallel imaging technique applied to the MPRAGE sequence. Results: Intraclass correlation tests show that almost perfect agreement between repeated measurements of both segmented brain parenchyma fraction and regional measurement of hippocampi. The protocol is suitable for both global and regional volumetric measurement dementia patients. Conclusion: In summary, these results indicate that parallel imaging can be used without detrimental effect to brain tissue segmentation and volumetric measurement and should be considered for both clinical and research studies where longitudinal measurements of brain tissue volumes are of interest. © 2009 Lindholm et al; licensee BioMed Central Ltd.
引用
收藏
相关论文
共 50 条
  • [1] MR breast imaging: a comparative analysis of conventional and parallel imaging acquisition
    Orlacchio, A.
    Bolacchi, E.
    Rotili, A.
    Cossu, E.
    Tanga, I.
    Cozzolino, V.
    Simonetti, G.
    RADIOLOGIA MEDICA, 2008, 113 (04): : 465 - 476
  • [2] Improved Parallel MR Imaging Using a Coefficient Penalized Regularization for GRAPPA Reconstruction
    Liu, Wentao
    Tang, Xin
    Ma, Yajun
    Gao, Jia-Hong
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (04) : 1109 - 1114
  • [3] The Effect of Reconstruction and Acquisition Parameters for GRAPPA-Based Parallel Imaging on the Image Quality
    Bauer, S.
    Markl, M.
    Honal, M.
    Jung, B. A.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (02) : 402 - 409
  • [4] Parallel MR imaging
    Deshmane, Anagha
    Gulani, Vikas
    Griswold, Mark A.
    Seiberlich, Nicole
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (01) : 55 - 72
  • [5] Iterative GRAPPA (iGRAPPA) for improved parallel imaging reconstruction
    Zhao, Tiejun
    Hu, Xiaoping
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (04) : 903 - 907
  • [6] High-resolution continuously acquired peripheral MR angiography featuring partial parallel imaging GRAPPA
    Zenge, Michael O.
    Vogt, Florian M.
    Brauck, Katja
    Joekel, Michaela
    Barkhausen, Joerg
    Kannengiesser, Stephan
    Ladd, Mark E.
    Quick, Harald H.
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (04) : 859 - 865
  • [7] Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA)
    Breuer, FA
    Kellman, P
    Griswold, MA
    Jakob, PM
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (04) : 981 - 985
  • [8] Parallel magnetic resonance imaging using the GRAPPA operator formalism
    Griswold, MA
    Blaimer, M
    Breuer, F
    Heidemann, RM
    Mueller, M
    Jakob, PM
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (06) : 1553 - 1556
  • [9] Impact of Reduced k-Space Acquisition on Pathologic Detectability for Volumetric MR Spectroscopic Imaging
    Sabati, Mohammad
    Zhan, Jiping
    Govind, Varan
    Arheart, Kristopher L.
    Maudsley, Andrew A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (01) : 224 - 234
  • [10] MR Imaging via Reduced Generalized Autocalibrating Partially Parallel Acquisition Compressed Sensing
    Islam, Sheikh Rafiul
    Maity, Seba
    Maity, Santi P.
    Ray, Ajoy Kumar
    COMPUTER VISION, GRAPHICS, AND IMAGE PROCESSING, ICVGIP 2016, 2017, 10481 : 345 - 357