A liquid chromatographic method for the determination of histamine in immunoglobulin preparation using solid phase extraction and pre-column derivatization

被引:0
作者
Nam Hee Kim
Youmie Park
Eun Sook Jeong
Chang-Soo Kim
Min Kyo Jeoung
Kyoung Soon Kim
Seung-Hwa Hong
Jong-Keun Son
Jin Tae Hong
II-young Park
Dong-Cheul Moon
机构
[1] Chungbuk National University,College of Pharmacy, CBITRC
[2] Korea Food and Drug Administration (KFDA),College of Pharmacy
[3] Yeungnam University,undefined
来源
Archives of Pharmacal Research | 2007年 / 30卷
关键词
Immunoglobulin preparation; Histamine; Solid-phase extraction; PS-DVB; Fluorescent detection; o-Phthaldialdehyde;
D O I
暂无
中图分类号
学科分类号
摘要
An immunoglobulin (IgG) preparation with micro-amount of histamine fixed on the active protein fraction has been used to increase the resistance to allergic reactions. However, excessive histamine may cause hypo- or hypertension, headache, or anaphylactic shock and so the histamine content of the drug is strictly controlled by a regulation: 0.15 μg of histamine dihydrochloride is allowed for 12 mg of immunoglobulin. In this study, a liquid Chromatographic method to determine micro-amount of histamine in the pharmaceutical was developed and validated. This method include a sample cleanup by a solid phase extraction (SPE) using a polystyrenedivinyl benzene (PS-DVB) polymeric sorbent and high-performance liquid chromatography after precolumn fluorescent labeling of the histamine with o-phthaldialdehyde. The drug sample was loaded to the SPE cartridge after adjusting to pH 9.5. After successive washings of the cartridge with water and 30% aqueous methanol, histamine was then eluted with 100 mM sodium acetate (pH 9.5)-methanol (20:80, v/v). An aliquot from the eluate was labeled with o-phthaldialdehyde-mercaptoethanol (OPA-ME) for fluorescence detection at the excitation maximum of 340 nm and emission maximum of 450 nm. HPLC analysis was performed on a phenyl-hexyl column with an acetonitrile-phosphate buffer (pH 6.8; 50 μM) (35:65, v/v) as the mobile phase. The retention times of histamine and 3-methylhistamine (IS) were approximately 7.2 and 9.5 min, respectively. The quantitation range was between 0.01-0.2 mg/mL of histamine showing good linearity (r=0.9996). This analytical method would provide a potential mean for the strict control of histamine content in the pharmaceutical product.
引用
收藏
相关论文
共 79 条
[1]  
Armagan O.(2007)Current analytical methods for the determination of biogenic amines in foods Food Chemistry 103 1475-1486
[2]  
Ayoub M.(2000)The anti-allergic drug histaglobin inhibits NF-kappaB nuclear translocation and down-regulates proinflammatory cytokines Int. J. Immunopharmacol. 22 755-763
[3]  
Mittenbuhler K.(1996)Biogenic amines in wine: A review of analytical methods J. Int.Sci.Vigne. Vin. 30 85- 101
[4]  
Sutterlin B. W.(1980)Scombrotoxic fish poisoning: feature of the first 50 incidents to be reported in Britain (1976’9) Br. Med J. 281 71-72
[5]  
Bessler W. G(1999)Method development and cultivar-related differences of nine biogenic amines in Ontario wines Food Chemistry 64 49-58
[6]  
Busto O.(1999)Therapeutic activeness of histaglobin preparations in patients with allergic rhinitis and chronic urticaria Ter. Arkh. 71 57-62
[7]  
Guasch J.(1979)Inhibition of rat mast cell degranulation and histamine release by histamine-rat gamma-globulin conjugate Int. Arch. Allergy. Appl. Immunol. 59 403-407
[8]  
Borrul R(1986)Changes of histaminopexy in patients with bronchial asthma and chronic urticaria after histaglobin administration Arch. Immunol. Ther. Exp. (Warsz) 34 385- 389
[9]  
Gilbert R. J.(2002)Determination of histamine in the whole blood of colon cancer patients J. Chromatogr. B. 780 331-339
[10]  