Shear strength and failure criterion analysis of steel fiber reinforced concrete exposed to elevated temperature under combined compression-shear loading

被引:0
|
作者
Yang, Haifeng [1 ,2 ]
Luo, Jinhai [1 ,2 ]
Yang, Qingmei [1 ,2 ]
Liu, Chengli [1 ,2 ]
机构
[1] Guangxi Univ, Coll Civil Engn & Architecture, State Key Lab Featured Met Mat & Life Cycle Safety, 100 East Univ Rd, Nanning 530004, Guangxi, Peoples R China
[2] Guangxi Univ, Coll Civil Engn & Architecture, Guangxi Key Lab Disaster Prevent & Struct Safety, 100 East Univ Rd, Nanning 530004, Guangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Steel fiber reinforced concrete; Compression-shear loading; High temperature; Failure pattern; Failure criterion; MECHANICAL-PROPERTIES; BEHAVIOR;
D O I
10.1617/s11527-024-02362-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Adding steel fiber to concrete preparation to enhance residual strength and ductility is a potential solution to improve reliability of specific concrete members with compression-shear loading zones, such as deep beams, trusses and column joints, after exposure to high temperature. In this study, the primary aim is to explore the impact of steel fibers on concrete behaviors in shear failure under various exposure temperatures and normal stress. Compression-shear performance of steel fiber reinforced concrete was tested under several conditions of volume fraction of steel fibers (Vsf = 0, 1.0%, 1.5%, and 2.0%), exposure temperature (T = 20 degrees C, 200 degrees C, 400 degrees C, and 600 degrees C), and normal stress ratios (k = 0, 0.2, 0.4, 0.6, and 0.8), and compression-shear failure patterns and load-shear displacement curves were investigated. The results demonstrate that incorporation of steel fibers enhance ductile behavior of specimen under compression-shear loading, with a higher presence of friction traces and jagged edges appearing at shear interface. After temperature treatment above 400degree celsius, the characteristics of tensile failure gradually disappear, while more crushed failure occurs. The peak shear strengths decrease significantly with the increase of exposure temperature. For different volume fraction of steel fibers (1.0%, 1.5%, and 2.0%), the shear strengths at 400 degrees C increase by 12.5%, 15.9%, and 11.1%, respectively. The optimal compression-shear strengthening effect is Vsf = 1.5%. Finally, according to the experimental results, the equivalent strength tau oct - sigma oct theoretical calculation model is determined to be the most suitable compression-shear strength prediction of SFRC at various temperatures.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Shear strength and failure criterion of carbon fiber reinforced coral concrete under combined compression-shear stresses
    Liu, Bing
    Ye, Junpeng
    Liu, Xiaoyan
    Lin, Weixin
    Deng, Zhiheng
    Liu, Qizhou
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 325
  • [2] Shear strength and failure criterion of geopolymer coral aggregate concrete under compression-shear loading
    Yang, Haifeng
    Yang, Qingmei
    Luo, Jinhai
    Jiang, Jiasheng
    Mei, Junjie
    Liu, Anran
    JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [3] Experimental study and failure criterion analysis of plain concrete under combined compression-shear stress
    Yu, Zhenpeng
    Huan, Qiao
    Xie, Xinghua
    Xiao, Ning
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 179 : 198 - 206
  • [4] Compression-shear performance of steel fiber reinforced rubber concrete
    Yang, Haifeng
    Lu, Xiancheng
    Gong, Machi
    Yang, Peng
    JOURNAL OF BUILDING ENGINEERING, 2023, 75
  • [5] A numerical prediction of failure probability under combined compression-shear loading for unidirectional fiber reinforced composites
    Safdar, N.
    Daum, B.
    Rolfes, R.
    MECHANICS OF MATERIALS, 2022, 171
  • [6] Experimental study on the shear failure model for concrete under compression-shear loading
    Shu, Xiaojuan
    Luo, Yili
    Zhao, Chao
    Dai, Zhicheng
    Zhong, Xingu
    Zhang, Tianyu
    COMPUTERS AND CONCRETE, 2022, 29 (02): : 81 - 92
  • [7] Mechanical performance and failure criterion of coral concrete under combined compression-shear stresses
    Liu, Bing
    Zhou, Jingkai
    Wen, Xiaoyan
    Guo, Jianhua
    Deng, Zhiheng
    Hu, Xu
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 288
  • [8] BEHAVIOR OF NORMAL AND HIGH-STRENGTH CONCRETE UNDER COMBINED COMPRESSION-SHEAR LOADING
    KHALOO, AR
    AHMAD, SH
    ACI MATERIALS JOURNAL, 1988, 85 (06) : 551 - 559
  • [9] Experimental Study and Failure Mechanism Analysis of Rubber Fiber Concrete under the Compression-Shear Combined Action
    Zhang, Juntao
    Yu, Zhenpeng
    Sun, Xinjian
    Zhang, Guangli
    Pan, Wenguo
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2021, 2021
  • [10] Mechanical properties of steel fiber reinforced recycled concrete under compression-shear stress state
    Chen, Yuliang
    He, Qin
    Jiang, Rui
    Ye, Peihuan
    JOURNAL OF BUILDING ENGINEERING, 2024, 93