Metal artifact reduction in patients with dental implants using multispectral three-dimensional data acquisition for hybrid PET/MRI

被引:29
作者
Gunzinger J.M. [1 ]
Delso G. [2 ]
Boss A. [3 ]
Porto M. [1 ]
Davison H. [1 ]
von Schulthess G.K. [1 ]
Huellner M. [1 ,4 ]
Stolzmann P. [1 ,4 ]
Veit-Haibach P. [1 ,3 ]
Burger I.A. [1 ,3 ]
机构
[1] Department of Medical Radiology, Division of Nuclear Medicine, University Hospital Zurich, Ramistr. 100, Zurich
[2] Global MR Applications and Workflow, GE Healthcare, Zurich
[3] Department of Medical Radiology, Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Ramistr. 100, Zurich
[4] Department of Medical Radiology, Institute of Neuroradiology, University Hospital Zurich, Ramistr. 100, Zurich
关键词
Attenuation correction; Image noise; MAVRIC; Signal voids;
D O I
10.1186/s40658-014-0102-z
中图分类号
学科分类号
摘要
Background: Hybrid positron emission tomography/magnetic resonance imaging (PET/MRI) shows high potential for patients with oropharyngeal cancer. Dental implants can cause substantial artifacts in the oral cavity impairing diagnostic accuracy. Therefore, we evaluated new MRI sequences with multi-acquisition variable-resonance image combination (MAVRIC SL) in comparison to conventional high-bandwidth techniques and in a second step showed the effect of artifact size on MRI-based attenuation correction (AC) with a simulation study. Methods: Twenty-five patients with dental implants prospectively underwent a trimodality PET/CT/MRI examination after informed consent was obtained under the approval of the local ethics committee. A conventional 3D gradient-echo sequence (LAVA-Flex) commonly used for MRI-based AC of PET (acquisition time of 14 s), a T1w fast spin-echo sequence with high bandwidth (acquisition time of 3.2 min), as well as MAVRIC SL sequence without and with increased phase acceleration (MAVRIC, acquisition time of 6 min; MAVRIC-fast, acquisition time of 3.5 min) were applied. The absolute and relative reduction of the signal void artifact was calculated for each implant and tested for statistical significance using the Wilcoxon signed-rank test. The effect of artifact size on PET AC was simulated in one case with a large tumor in the oral cavity. The relative difference of the maximum standardized uptake value (SUVmax) in the tumor was calculated for increasing artifact sizes centered over the second molar. Results: The absolute reduction of signal void from LAVA-Flex sequences to the T1-weighted fast spin-echo (FSE) sequences was 416 mm2 (range 4 to 2,010 mm2) to MAVRIC 481 mm2 (range 12 to 2,288 mm2) and to MAVRIC-fast 486 mm2 (range 39 to 2,209 mm2). The relative reduction in signal void was significantly improved for both MAVRIC and MAVRIC-fast compared to T1 FSE (−75%/− 78% vs. − 62%, p < 0.001 for both). The relative error for SUVmax was negligible for artifacts of 0.5-cm diameter (−0.1%), but substantial for artifacts of 5.2-cm diameter (−33%). Conclusions: MAVRIC-fast could become useful for artifact reduction in PET/MR for patients with dental implants. This might improve diagnostic accuracy especially for patients with tumors in the oropharynx and substantially improve accuracy of PET quantification. © 2014, Gunzinger et al; licensee Springer.
引用
收藏
页码:1 / 14
页数:13
相关论文
共 37 条
[1]  
Becker M., Moulin G., Kurt A.M., Dulgerov P., Vukanovic S., Zbaren P., Marchal F., Rufenacht D.A., Terrier F., Non-squamous cell neoplasms of the larynx: radiologic-pathologic correlation, Radiographics, 18, pp. 1189-1209, (1998)
[2]  
Loevner L.A., Image-guided procedures of the head and neck: the radiologist's arsenal, Otolaryngol Clin North Am, 41, pp. 231-250, (2008)
[3]  
Zbaren P., Becker M., Lang H., Staging of laryngeal cancer: endoscopy, computed tomography and magnetic resonance versus histopathology, Eur Arch Otorhinolaryngol, 254, pp. S117-S122, (1997)
[4]  
Ouyang T., Branstetter B.F., Advances in head and neck imaging, Oral Maxillofac Surg Clin North Am, 22, pp. 107-115, (2010)
[5]  
Reske S.N., Kotzerke J., FDG-PET for clinical use. Results of the 3rd German Interdisciplinary Consensus Conference, “Onko-PET III”, 21 July and 19 September 2000, Eur J Nucl Med, 28, pp. 1707-1723, (2001)
[6]  
Yamazaki Y., Saitoh M., Notani K., Tei K., Totsuka Y., Takinami S., Kanegae K., Inubushi M., Tamaki N., Kitagawa Y., Assessment of cervical lymph node metastases using FDG-PET in patients with head and neck cancer, Ann Nucl Med, 22, pp. 177-184, (2008)
[7]  
Branstetter B.F., Blodgett T.M., Zimmer L.A., Snyderman C.H., Johnson J.T., Raman S., Meltzer C.C., Head and neck malignancy: is PET/CT more accurate than PET or CT alone?, Radiology, 235, pp. 580-586, (2005)
[8]  
Schoder H., Yeung H.W., Gonen M., Kraus D., Larson S.M., Head and neck cancer: clinical usefulness and accuracy of PET/CT image fusion, Radiology, 231, pp. 65-72, (2004)
[9]  
Huang S.H., Chien C.Y., Lin W.C., Fang F.M., Wang P.W., Lui C.C., Huang Y.C., Hung B.T., Tu M.C., Chang C.C., A comparative study of fused FDG PET/MRI, PET/CT, MRI, and CT imaging for assessing surrounding tissue invasion of advanced buccal squamous cell carcinoma, Clin Nucl Med, 36, pp. 518-525, (2011)
[10]  
Kuhn F.P., Hullner M., Mader C.E., Kastrinidis N., Huber G.F., von Schulthess G.K., Kollias S., Veit-Haibach P., Contrast-enhanced PET/MR imaging versus contrast-enhanced PET/CT in head and neck cancer: how much MR information is needed?, J Nucl Med, 55, pp. 551-558, (2014)