Prospective navigator-echo-based real-time triggering of fetal head movement for the reduction of artifacts
被引:0
|
作者:
H. Bonel
论文数: 0引用数: 0
h-index: 0
机构:University Hospital Berne-Inselspital,Institute of Diagnostic, Interventional and Pediatric Radiology
H. Bonel
K. A. Frei
论文数: 0引用数: 0
h-index: 0
机构:University Hospital Berne-Inselspital,Institute of Diagnostic, Interventional and Pediatric Radiology
K. A. Frei
L. Raio
论文数: 0引用数: 0
h-index: 0
机构:University Hospital Berne-Inselspital,Institute of Diagnostic, Interventional and Pediatric Radiology
L. Raio
M. Meyer-Wittkopf
论文数: 0引用数: 0
h-index: 0
机构:University Hospital Berne-Inselspital,Institute of Diagnostic, Interventional and Pediatric Radiology
M. Meyer-Wittkopf
L. Remonda
论文数: 0引用数: 0
h-index: 0
机构:University Hospital Berne-Inselspital,Institute of Diagnostic, Interventional and Pediatric Radiology
L. Remonda
R. Wiest
论文数: 0引用数: 0
h-index: 0
机构:University Hospital Berne-Inselspital,Institute of Diagnostic, Interventional and Pediatric Radiology
R. Wiest
机构:
[1] University Hospital Berne-Inselspital,Institute of Diagnostic, Interventional and Pediatric Radiology
[2] Freiburgstrasse,Women‘s’ Hospital
[3] University of Berne,Institute of Diagnostic and Interventional Neuroradiology (DIN), Inselspital
[4] University of Berne,undefined
来源:
European Radiology
|
2008年
/
18卷
关键词:
Magnetic resonance imaging;
Navigator;
Artifacts;
Motion;
Fetal;
D O I:
暂无
中图分类号:
学科分类号:
摘要:
The purpose of this study was to evaluate the neuroimaging quality and accuracy of prospective real-time navigator-echo acquisition correction versus untriggered intrauterine magnetic resonance imaging (MRI) techniques. Twenty women in whom fetal motion artifacts compromised the neuroimaging quality of fetal MRI taken during the 28.7 ± 4 week of pregnancy below diagnostic levels were additionally investigated using a navigator-triggered half-Fourier acquired single-shot turbo-spin echo (HASTE) sequence. Imaging quality was evaluated by two blinded readers applying a rating scale from 1 (not diagnostic) to 5 (excellent). Diagnostic criteria included depiction of the germinal matrix, grey and white matter, CSF, brain stem and cerebellum. Signal-difference-to-noise ratios (SDNRs) in the white matter and germinal zone were quantitatively evaluated. Imaging quality improved in 18/20 patients using the navigator echo technique (2.4 ± 0.58 vs. 3.65 ± 0.73 SD, p < 0.01 for all evaluation criteria). In 2/20 patients fetal movement severely impaired image quality in conventional and navigated HASTE. Navigator-echo imaging revealed additional structural brain abnormalities and confirmed diagnosis in 8/20 patients. The accuracy improved from 50% to 90%. Average SDNR increased from 0.7 ± 7.27 to 19.83 ± 15.71 (p < 0.01). Navigator-echo-based real-time triggering of fetal head movement is a reliable technique that can deliver diagnostic fetal MR image quality despite vigorous fetal movement.
机构:
Univ Calif San Diego, Dept Cognit Sci, La Jolla, CA 92093 USAUniv Calif San Diego, Dept Cognit Sci, La Jolla, CA 92093 USA
White, Nathan
Roddey, Cooper
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Diego, Dept Neurosci, La Jolla, CA 92093 USAUniv Calif San Diego, Dept Cognit Sci, La Jolla, CA 92093 USA
Roddey, Cooper
Shankaranarayanan, Ajit
论文数: 0引用数: 0
h-index: 0
机构:
GE Healthcare, Global Appl Sci Lab, Waukesha, WI USAUniv Calif San Diego, Dept Cognit Sci, La Jolla, CA 92093 USA
Shankaranarayanan, Ajit
Han, Eric
论文数: 0引用数: 0
h-index: 0
机构:
GE Healthcare, Global Appl Sci Lab, Waukesha, WI USAUniv Calif San Diego, Dept Cognit Sci, La Jolla, CA 92093 USA
Han, Eric
Rettmann, Dan
论文数: 0引用数: 0
h-index: 0
机构:
GE Healthcare, Global Appl Sci Lab, Waukesha, WI USAUniv Calif San Diego, Dept Cognit Sci, La Jolla, CA 92093 USA
Rettmann, Dan
Santos, Juan
论文数: 0引用数: 0
h-index: 0
机构:
Stanford Univ, Dept Elect Engn, Palo Alto, CA 94304 USAUniv Calif San Diego, Dept Cognit Sci, La Jolla, CA 92093 USA
Santos, Juan
Kuperman, Josh
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Diego, Dept Radiol, La Jolla, CA 92093 USAUniv Calif San Diego, Dept Cognit Sci, La Jolla, CA 92093 USA
Kuperman, Josh
Dale, Anders
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif San Diego, Dept Neurosci, La Jolla, CA 92093 USA
Univ Calif San Diego, Dept Radiol, La Jolla, CA 92093 USAUniv Calif San Diego, Dept Cognit Sci, La Jolla, CA 92093 USA