Determination of Pu-239 content in Pu–Be neutron sources using Gamma-ray spectrometry

被引:0
|
作者
P. Dryák
P. Kovář
机构
[1] Czech Metrology Institute,
来源
Journal of Radioanalytical and Nuclear Chemistry | 2014年 / 299卷
关键词
Pu–Be neutron source; Gamma-ray spectrometry; Plutonium;
D O I
暂无
中图分类号
学科分类号
摘要
The need to determine the content of plutonium in Pu–Be neutron sources of Russian provenience arises from the administrative regulations applying to nuclear materials. The determination of a plutonium (all isotopes) amount was based on the measurement of an activity Pu-239. Gamma-ray spectrometry with semiconductor detector HPGe was applied. The determination of plutonium (all isotopes) amount was based on the measurement of Pu-239 activity by means of Gamma-ray spectrometry with semiconductor detector HPGe. Gamma lines of radionuclides Am-241, Pu-238, Pu-239 and Pu-241 were detected in spectra. Detection efficiencies were calculated by Monte Carlo method using MCNP4A code. Computations were done for several hypothetical plutonium amounts. Activities determined from peak areas of 129 and 413 keV photons emitted from Pu-239 were confronted. The right amount was established under the condition of equality of both activities.
引用
收藏
页码:61 / 64
页数:3
相关论文
共 50 条
  • [21] Using 239Pu as a tracer for fine sediment sources in the Daly River, Northern Australia
    Lal, R.
    Fifield, L. K.
    Tims, S. G.
    Wasson, R. J.
    Howe, D.
    HEAVY ION ACCELERATOR SYMPOSIUM 2014, 2015, 91
  • [22] A METHOD OF EFFICIENCY CALIBRATION FOR DISK SOURCES IN GAMMA-RAY SPECTROMETRY
    Radu, Daniela
    Stanga, Doru
    Sima, Octavian
    ROMANIAN REPORTS IN PHYSICS, 2009, 61 (02) : 203 - 213
  • [23] Determination of plutonium isotopes (238,239,240Pu) and strontium (90Sr) in seafood using alpha spectrometry and liquid scintillation spectrometry
    Shin, Choonshik
    Choi, Hoon
    Kwon, Hye-Min
    Jo, Hye-Jin
    Kim, Hye-Jeong
    Yoon, Hae-Jung
    Kim, Dong-Sul
    Kang, Gil-Jin
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2017, 177 : 151 - 157
  • [24] Rapid determination of ultra-trace plutonium isotopes (239Pu, 240Pu and 241Pu) in small-volume human urine bioassay using sector-field inductively coupled plasma mass spectrometry
    Ni, Youyi
    Zheng, Jian
    Guo, Qiuju
    Men, Wu
    Tagami, Keiko
    Uchida, Shigeo
    ANALYTICA CHIMICA ACTA, 2018, 1000 : 85 - 92
  • [25] Determination of 241Pu by the method of disturbed radioactive equilibrium using 2πα-counting and precision gamma-spectrometry
    Alekseev, I.
    Kuzmina, T.
    APPLIED RADIATION AND ISOTOPES, 2016, 110 : 212 - 217
  • [26] Determination of 238U in ground-water samples using gamma-ray spectrometry
    Korun, M.
    Kovacic, K.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (03) : 636 - 640
  • [27] On within sample homogeneity testing using gamma-ray spectrometry
    Suvaila, Rares
    Stancu, Elena
    Sima, Octavian
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 2144 - 2148
  • [28] Determination of ultra-low level of 239, 240Pu in grass/vegetable sample by compact accelerator mass spectrometry
    Luo, Maoyi
    Liu, Daqian
    Dai, Xiongxin
    Wu, Yang
    Yuan, Ni
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2023, 332 (04) : 999 - 1005
  • [29] Line profile analysis of dislocation densities of the δ-phase 239Pu-2.0 at %Ga alloy using neutron diffraction
    Zhang, Jianzhong
    Clausen, Bjorn
    Smith, Alice I.
    Freibert, Franz J.
    Vogel, Sven C.
    Brown, Donald W.
    JOURNAL OF NUCLEAR MATERIALS, 2019, 517 : 152 - 156
  • [30] Isolation of 236U and 239,240Pu from seawater samples and its determination by Accelerator Mass Spectrometry
    Lopez-Lora, Mercedes
    Chamizo, Elena
    Villa-Alfageme, Maria
    Hurtado-Bermudez, Santiago
    Casacuberta, Nuria
    Garcia-Leon, Manuel
    TALANTA, 2018, 178 : 202 - 210