Determination of Pu-239 content in Pu–Be neutron sources using Gamma-ray spectrometry

被引:0
|
作者
P. Dryák
P. Kovář
机构
[1] Czech Metrology Institute,
来源
Journal of Radioanalytical and Nuclear Chemistry | 2014年 / 299卷
关键词
Pu–Be neutron source; Gamma-ray spectrometry; Plutonium;
D O I
暂无
中图分类号
学科分类号
摘要
The need to determine the content of plutonium in Pu–Be neutron sources of Russian provenience arises from the administrative regulations applying to nuclear materials. The determination of a plutonium (all isotopes) amount was based on the measurement of an activity Pu-239. Gamma-ray spectrometry with semiconductor detector HPGe was applied. The determination of plutonium (all isotopes) amount was based on the measurement of Pu-239 activity by means of Gamma-ray spectrometry with semiconductor detector HPGe. Gamma lines of radionuclides Am-241, Pu-238, Pu-239 and Pu-241 were detected in spectra. Detection efficiencies were calculated by Monte Carlo method using MCNP4A code. Computations were done for several hypothetical plutonium amounts. Activities determined from peak areas of 129 and 413 keV photons emitted from Pu-239 were confronted. The right amount was established under the condition of equality of both activities.
引用
收藏
页码:61 / 64
页数:3
相关论文
共 50 条
  • [1] Determination of Pu-239 content in Pu-Be neutron sources using Gamma-ray spectrometry
    Dryak, P.
    Kovar, P.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 299 (01) : 61 - 64
  • [2] DETERMINATION OF BURNUP AND PU/U RATIO OF PWR SPENT FUELS BY GAMMA-RAY SPECTROMETRY
    Park, Kwang-June
    Ju, June-Sik
    Kim, Jung-Suk
    Shin, Hee-Sung
    Chun, Yong-Bum
    Kim, Ho-Dong
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2009, 41 (10) : 1307 - 1314
  • [3] Determination of 239Pu and 240Pu isotope ratio for a nuclear bomb particle using X-ray spectrometry in conjunction with γ-ray spectrometry and non-destructive α-particle spectrometry
    Pollanen, R.
    Ruotsalainen, K.
    Toivonen, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 610 (02) : 515 - 521
  • [4] Fast Determination of Pu-239 Concentration in Environmental Radioactive Aerosols by Inductively Coupled Plasma Mass Spectrometry
    Su Yong-Yang
    Li Zhi-Ming
    Dong Hong-Bo
    Xu Jiang
    Ren Xiang-Jun
    Zhai Li-Hua
    Zhou Guo-Qing
    Li Mei
    Yi Xiao-Wei
    Zhu Feng-Rong
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (08) : 1139 - 1143
  • [5] 239Pu, 240Pu, and 241Am Determination in Hot Particles by Low Level Gamma-Spectrometry
    Jimenez-Ramos, M. G.
    Hurtado, S.
    Chamizo, E.
    Garcia-Tenorio, R.
    Leon-Vintro, L.
    Mitchell, P. I.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (11) : 4247 - 4252
  • [6] Rapid and precise determination of the 238Pu/239Pu isotope ratio using thermal ionization mass spectrometry
    Goswami, Preeti
    Paul, Sumana
    Bhushan, K. Sasi
    Jaison, P. G.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2024, 39 (02) : 500 - 507
  • [7] Determination of femtogram quantities of 239Pu and 240Pu in bioassay samples by thermal ionization mass spectrometry
    N. L. Elliot
    G. A. Bickel
    S. H. Linauskas
    L. M. Paterson
    Journal of Radioanalytical and Nuclear Chemistry, 2006, 267 : 637 - 650
  • [8] Accuracy and precision of 238PU determination at fg level by alpha spectrometry using 239PU and 240Pu amount analyzed by ICP-MS
    Macsik, Zsuzsanna
    Shinonaga, Taeko
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (12) : 2147 - 2152
  • [9] Application of gamma-ray spectrometry, neutron multiplicity counting and calorimetry for non-destructive assay of U-Pu mixed samples
    Patra, Sabyasachi
    Tripathi, Rahul
    Pujari, P. K.
    APPLIED RADIATION AND ISOTOPES, 2021, 176
  • [10] 240Pu/239Pu isotopic ratio measurements in micrometric Pu and MOX particles using Secondary Ion Mass Spectrometry
    Diacre, Aurelie
    Faure, Anne-Laure
    Cornaton, Manon
    Pointurier, Fabien
    Evrard, Olivier
    TALANTA, 2023, 252