Choroidal thickness findings in two siblings with nanophthalmos by swept source-OCT: a case report

被引:3
|
作者
Kaneko H. [1 ]
Shinojima A. [1 ]
Ryusaburo M. [1 ]
Kawamura A. [1 ]
Yuzawa M. [1 ]
机构
[1] Division of Ophthalmology, Department of Visual Science, Nihon University, School of Medicine, Nihon University Hospital, 1-6 Surugadai, Kanda, Chiyoda-ku, 101-8309, Tokyo
关键词
Axial length; Choroidal thickness; Hyperopia; Nanophthalmos; Optical coherence tomography;
D O I
10.1186/s13104-016-2359-x
中图分类号
学科分类号
摘要
Background: We investigated choroidal thicknesses at five sites in two siblings (four eyes) with nanophthalmos using swept-source optical coherence tomography. Case presentation: Case 1, a 51-year-old Japanese female with high hyperopia (Right: +20.5 Dioptors, Left: +19.5 Dioptors), had axial lengths of 15.6 mm in both eyes. Case 2, a 55-year-old Japanese male with high hyperopia (Right: +22.5 Dioptors, Left: +22.8 Dioptors), had axial lengths of 14.8 and 14.7 mm in the right and left eyes, respectively. Choroidal thickness was measured at five sites in each eye using swept-source optical coherence tomography; subfoveal, nasal, temporal, superior and inferior (the 4 non-subfoveal sites were measured 3000 µm from the fovea). Conclusion: The mean choroidal thickness was 355.8 ± 63.6 μm at the subfoveal, 466.3 ± 85.1 μm at the nasal, 274.8 ± 77.2 μm at the temporal, 396.8 ± 54.6 μm at the superior, and 480.8 ± 66.8 μm at the inferior (mean ± standard deviation) site. Choroidal thickness was maximal at the inferior site. The choroid was thinnest, in diminishing order, at the nasal, superior, subfoveal and temporal sites. © 2017 The Author(s).
引用
收藏
页码:1 / 4
页数:3
相关论文
共 50 条
  • [31] Assessment of Retinal Neurodegeneration and Choroidal Thickness in COVID-19 Patients Using Swept-Source OCT Technology
    Cetinkaya, Tugba
    Kurt, Muhammed M.
    Akpolat, Cetin
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2021, 238 (10) : 1092 - 1097
  • [32] Wide-Field Swept-Source OCT Analysis of Interocular Symmetry of Choroidal Thickness in Subjects with Uncomplicated Pachychoroid
    Kim, Min-Su
    Lim, Hyung-Bin
    Lee, Woo-Hyuk
    Won, Yeo-Kyoung
    Nam, Ki-Yup
    Kim, Jung-Yeul
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (18)
  • [33] Automated 2D and 3D assessment of choroidal thickness and vasculature with swept-source OCT
    Zhou, Hao
    Chu, Zhongdi
    Zhang, Qinqin
    Dai, Yining
    Gregori, Giovanni
    Rosenfeld, Philip J.
    Wang, Ruikang K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [34] Choroidal thickness and structural glaucoma parameters in glaucomatous, preperimetric glaucomatous, and healthy eyes using swept-source OCT
    Akil, Handan
    Al-Sheikh, Mayss
    Falavarjani, Khalil Ghasemi
    Francis, Brian
    Chopra, Vikas
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2017, 27 (05) : 548 - 554
  • [35] Agreement between anterior segment swept source-OCT and Scheimpflug imaging corneal aberration measurements in healthy eyes
    Perez-Bartolome, Francisco
    Feu-Basilio, Silvia
    Rocha-de Lossada, Carlos
    Blanco-Dominguez, Irene
    Torras-Sanvicens, Josep
    Peraza-Nieves, Jorge
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (06) : 3363 - 3371
  • [36] Swept-Source OCT Analysis of the Margin of Choroidal Coloboma New Insights
    Jain, Shreyans
    Kumar, Vinod
    Salunkhe, Nitesh
    Tewari, Ruchir
    Chandra, Parijat
    Kumar, Atul
    OPHTHALMOLOGY RETINA, 2020, 4 (01): : 92 - 99
  • [37] Comparison of Swept Source OCT Enface Choroidal Vasculography with ICG Angiography.
    Glittenberg, Carl
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [38] Agreement between anterior segment swept source-OCT and Scheimpflug imaging corneal aberration measurements in healthy eyes
    Bartolome, Francisco Perez
    Gonzalez, Rocio Vega
    Nieves, Jorge Peraza
    Moreno, Jose Maria Ruiz
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [39] Choroidal thickness in the era of swept-source optical coherence tomography
    Agarwal, Aniruddha
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (02) : 256 - 257
  • [40] Comparison of the Accuracy of Choroidal Thickness Measurements Using SD-OCT With and Without EDI and Swept Source OCT and Volumetric Analysis of the Choroid in Healthy Eyes
    Adhi, Mehreen
    Liu, Jonathan
    Qavi, Ahmed
    Grulkowski, Ireneusz
    Mohler, Kathrin
    Lu, Chen
    Kraus, Martin
    Waheed, Nadia
    Fujimoto, James
    Duker, Jay
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)