Reliability of ultrasound grading traditional score and new global OMERACT-EULAR score system (GLOESS): results from an inter- and intra-reading exercise by rheumatologists

被引:0
作者
Lucio Ventura-Ríos
Cristina Hernández-Díaz
Diana Ferrusquia-Toríz
Esteban Cruz-Arenas
Pedro Rodríguez-Henríquez
Ana Laura Alvarez del Castillo
Alfredo Campaña-Parra
Efrén Canul
Gerardo Guerrero Yeo
Juan Jorge Mendoza-Ruiz
Mario Pérez Cristóbal
Sandra Sicsik
Karina Silva Luna
机构
[1] Instituto Nacional de Rehabilitación Luis Guillermo Ibarra,Laboratorio de Ultrasonido Musculoesquelético y Articular
[2] Hospital General de Tlahuác,Servicio de Medicina Interna
[3] Unidad de Vigilancia Epidemiológica Hospitalaria–Investigación Sociomédica,Servicio de Reumatología
[4] Instituto Nacional de Rehabilitación Luis Guillermo Ibarra,undefined
[5] Hospital General Dr. Manuel Gea González,undefined
[6] Servicio de Reumatología,undefined
[7] Hospital de Especialidades # 25 IMSS,undefined
[8] Hospital General Regional # 20 IMSS,undefined
[9] Hospital General Regional # 1 IMSS,undefined
[10] Práctica privada,undefined
[11] Unidad de Patología Clínica,undefined
[12] Servicio de Reumatología,undefined
[13] Centro Médico Nacional Siglo XXI,undefined
[14] IMSS,undefined
[15] Unidad Médica de Alta Especialidad # 71 IMSS,undefined
[16] Servicio de Reumatología,undefined
[17] Hospital Universitario de Nuevo León,undefined
来源
Clinical Rheumatology | 2017年 / 36卷
关键词
GLOESS; Reliability; Synovitis score systems;
D O I
暂无
中图分类号
学科分类号
摘要
This study aims to test the reliability of ultrasound to graduate synovitis in static and video images, evaluating separately grayscale and power Doppler (PD), and combined. Thirteen trained rheumatologist ultrasonographers participated in two separate rounds reading 42 images, 15 static and 27 videos, of the 7-joint count [wrist, 2nd and 3rd metacarpophalangeal (MCP), 2nd and 3rd interphalangeal (IPP), 2nd and 5th metatarsophalangeal (MTP) joints]. The images were from six patients with rheumatoid arthritis, performed by one ultrasonographer. Synovitis definition was according to OMERACT. Scoring system in grayscale, PD separately, and combined (GLOESS—Global OMERACT-EULAR Score System) were reviewed before exercise. Reliability intra- and inter-reading was calculated with Cohen’s kappa weighted, according to Landis and Koch. Kappa values for inter-reading were good to excellent. The minor kappa was for GLOESS in static images, and the highest was for the same scoring in videos (k 0.59 and 0.85, respectively). Excellent values were obtained for static PD in 5th MTP joint and for PD video in 2nd MTP joint. Results for GLOESS in general were good to moderate. Poor agreement was observed in 3rd MCP and 3rd IPP in all kinds of images. Intra-reading agreement were greater in grayscale and GLOESS in static images than in videos (k 0.86 vs. 0.77 and k 0.86 vs. 0.71, respectively), but PD was greater in videos than in static images (k 1.0 vs. 0.79). The reliability of the synovitis scoring through static images and videos is in general good to moderate when using grayscale and PD separately or combined.
引用
收藏
页码:2799 / 2804
页数:5
相关论文
共 196 条
[1]  
Scheel AK(2006)Prospective 7 year follow up imaging study comparing radiography, ultrasonography, and magnetic resonance imaging in rheumatoid arthritis finger joints Ann Rheum Dis 65 595-600
[2]  
Hermann KG(2004)Ultrasonography of the metatarsophalangeal joints in rheumatoid arthritis: comparison with magnetic resonance imaging, conventional radiography, and clinical examination Arthritis Rheum 50 2103-2112
[3]  
Ohrndorf S(2010)Reliability of patient self-evaluation of swollen and tender joints in rheumatoid arthritis: a comparison study with ultrasonography, physician, and nurse assessments Arthritis Care Res (Hoboken) 62 1112-1119
[4]  
Werner C(1999)Arthritis of the finger joints: a comprehensive approach comparing conventional radiography, scintigraphy, ultrasound, and contrast enhanced magnetic resonance imaging Arthritis Rheum 42 1232-1245
[5]  
Schirmer C(2003)Ultrasonography is superior to clinical examination in the detection and localization of knee joint effusion in rheumatoid arthritis J Rheumatol 30 966-971
[6]  
Detert J(2017)Is it time to revisit the role of ultrasound in rheumatoid arthritis management? Ann Rheum Dis 76 7-8
[7]  
Szkudlarek M(2013)Prediction of radiographic damage in early arthritis by sonographic erosions and power Doppler signal: a longitudinal observational study Arthritis Care Res 65 896-902
[8]  
Narvestad E(2013)The ability of synovitis to predict structural damage in rheumatoid arthritis: a comparative study between clinical examination and ultrasound Ann Rheum Dis 72 665-671
[9]  
Klarlund M(2013)Ultrasonographic predictors for the development of joint damage in rheumatoid arthritis patients: a single joint prospective study Clin Exp Rheumatol 31 8-17
[10]  
Court-Payen M(2013)Very different performance of the power Doppler modalities of several ultrasound machines ascertained by a microvessel flow phantom Arthritis Res Ther 15 R162-381