Pre-drilling force and insertion torques during orthodontic mini-implant insertion in relation to root contact; [Vorbohr-Widerstand und Eindrehmomente bei der Insertion kieferorthopädischer Mini-Implantate in Abhängigkeit zu einem Zahnwurzel-Kontakt]

被引:0
作者
Wilmes B. [1 ]
Su Y.-Y. [1 ]
Sadigh L. [1 ]
Drescher D. [1 ]
机构
[1] Department of Orthodontics, Heinrich Heine University, 40225 Düsseldorf
来源
Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie | 2008年 / 69卷 / 1期
关键词
Mini-implants; Orthodontic anchorage; Primary stability; Root contact;
D O I
10.1007/s00056-008-0726-5
中图分类号
学科分类号
摘要
Background and Aim: The use of mi ni-implants for skeletal anchorage has greatly broadened the therapeutic spectrum in orthodontics over the last few years. The alveolar ridge is the most frequent insertion site, which however is associated with tooth injury, a risk not to be underestimated. The objective of this study was to examine the quantitative parameters of pre-drilling and implant insertion in association with the degree of a root contact. Material and Methods: Eleven lower jaw bones of adult pigs were prepared and embedded in resin. At 320 sites in the toothbearing alveolar ridge a 1.3 mm pre-drilling was carried out up to the complete implant length. The vertical force exerted against the pre-drilling upon penetration of the different bone layers and at a root contact was measured at a drift-speed of 0.5 mm/s. Dual Top™ screws (1.6 × 8 mm) were then inserted into the prepared implant sites, the insertion torques were measured, and recorded as a function of the rotation angle. After explantation, we prepared histological slides from the level of the implant's maximum diameter. The implant's contact with cortical and cancellous bone and to the roots was measured and correlated to vertical pre-drilling forces and insertion torques. Results: Vertical pre-drilling forces and insertion torques of orthodontic mini-implants varied in relation to the type of tissue penetrated and the degree of root contact. The insertion torques ranged from 32 to 345 Nmm and pre-drilling forces up to 6 N overall. Conclusion: Root contact can be recognized during pre-drilling by a distinct increase in resistance, and during mini-implant insertion by higher torques. © Urban & Vogel München 2008.
引用
收藏
页码:51 / 58
页数:7
相关论文
共 11 条
[1]  
Andreasen J.O., Kristerson L., The effect of limited drying or removal of the periodontal ligament: Periodontal healing after replantation of mature permanent incisors in monkeys, Acta Odontol Scand, 29, pp. 1-13, (1981)
[2]  
Asscherickx K., Vannet B.V., Wehrbein H., Sabzevar M.M., Root repair after injury from mini-screw, Clin Oral Implant Res, 16, pp. 575-578, (2005)
[3]  
Costa A., Raffaini M., Melsen B., Miniscrews as orthodontic anchorage: A preliminary report, Int J Adult Orthod Orthognath Surg, 13, pp. 201-209, (1998)
[4]  
Diedrich P., Fritz U., Kinzinger G., Movement of periodontally affected teeth after guided tissue regeneration (GTR) - an experimental pilot study in animals, J Orofac Orthop, 64, pp. 214-227, (2003)
[5]  
Fabbroni G., Aabed S., Mizen K., Starr D.G., Transalveolar screws and the incidence of dental damage: A prospective study, Int J Oral Maxillofac Surg, 33, pp. 442-446, (2004)
[6]  
Freudenthaler J.W., Haas R., Bantleon H.P., Bicortical titanium screws for critical orthodontic anchorage in the mandible: A preliminary report on clinical applications, Clin Oral Impl Res, 12, pp. 358-363, (2001)
[7]  
Kanomi R., Mini-implant for orthodontic anchorage, J Clin Orthod, 31, pp. 763-767, (1997)
[8]  
Roberts W.E., Smith R.K., Zilberman Y., Et al., Osseous adaptation to continuous loading of rigid endosseous implants, Am J Orthod, 86, pp. 95-111, (1984)
[9]  
Wehrbein H., Glatzmaier J., Mundwiller U., Diedrich P., The Orthosystem - a new implant system for orthodontic anchorage in the palate, J Orofac Orthop, 57, pp. 142-153, (1996)
[10]  
Wilmes B., Drescher D., Verankerung mit Miniimplantaten bei präprothetischer kieferorthopädischer Therapie., Kieferorthopädie, 20, pp. 203-208, (2006)