P792: a rapid clearance blood pool agent for magnetic resonance imaging: preliminary results

被引:0
|
作者
Marc Port
Claire Corot
Olivier Rousseaux
Isabelle Raynal
Ludovic Devoldere
Jean-Marc Idée
Anne Dencausse
Soizic Le Greneur
C. Simonot
Dominique Meyer
机构
[1] Guerbet,
[2] Chemical Research,undefined
来源
Magnetic Resonance Materials in Physics, Biology and Medicine | 2001年 / 12卷
关键词
MRI blood pool contrast agent; Gadolinium macrocycle; Chemistry; Relaxivity; Pharmacokinetics; Acute toxicity;
D O I
暂无
中图分类号
学科分类号
摘要
An original MRI contrast agent, called P792, is described. P792 is a gadolinium macrocyclic compound based on a Gd-DOTA structure substituted by hydrophilic arms. The chemical structure of P792 has been optimized in order to provide (1) a high r1 relaxivity in the clinical field for MRI: 29 mM−1 x s−1 at 60 MHz. (2) a high biocompatibility profile and (3) a high molecular volume: the apparent hydrodynamic volume of P792 is 125 times greater than that of Gd-DOTA. As a result of this high molecular volume, P792 presents an unusual pharmacokinetic profile, as it is a Rapid Clearance Blood Pool Agent (RCBPA) characterized by limited diffusion across the normal endothelium. The original pharmacokinetic properties of this RCBPA are expected to be well suited to MR coronary angiography, angiography, perfusion imaging (stress and rest), and permeability imaging (detection of ischemia and tumor grading). Further experimental imaging studies are ongoing to define the clinical value of this compound.
引用
收藏
页码:121 / 127
页数:6
相关论文
共 50 条
  • [1] P792:: a rapid clearance blood pool agent for magnetic resonance imaging:: preliminary results
    Port, M
    Corot, C
    Rousseaux, O
    Raynal, I
    Devoldere, L
    Idée, JM
    Dencausse, A
    Le Greneur, S
    Simonot, C
    Meyer, D
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2001, 12 (2-3) : 121 - 127
  • [2] Physicochemical and biological evaluation of P792, a rapid-clearance blood-pool agent for magnetic resonance imaging
    Port, M
    Corot, C
    Raynal, I
    Idee, JM
    Dencausse, A
    Lancelot, E
    Meyer, D
    Bonnemain, B
    Lautrou, J
    INVESTIGATIVE RADIOLOGY, 2001, 36 (08) : 445 - 454
  • [3] Coronary magnetic resonance angiography: Experimental evaluation of the new rapid clearance blood pool contrast medium P792
    Taupitz, M
    Schnorr, J
    Wagner, S
    Kivelitz, D
    Rogalla, P
    Claassen, G
    Dewey, M
    Robert, P
    Corot, C
    Hamm, B
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (05) : 932 - 938
  • [4] MR angiography with a new rapid clearance blood pool agent (P792): Initial experience in rabbits
    Ruehm, SG
    Schmitz-Cristina, H
    Violas, X
    Corot, C
    Debatin, JF
    ACADEMIC RADIOLOGY, 2002, 9 : S407 - S408
  • [5] Coronary magnetic resonance angiography: Experimental evaluation of the new rapid clearance blood pool contrast medium P792
    Taupitz, Matthias
    Schnorr, Jorg
    Wagner, Susanne
    Kivelitz, Dietmar
    Rogalla, Patrik
    Claa, Gerlind
    Dewey, Marc
    Robert, Philippe
    Corot, Claire
    Hamm, Bernd
    2001, John Wiley and Sons Inc. (46)
  • [6] Renal functional contrast-enhanced magnetic resonance imaging - Evaluation of a new rapid-clearance blood pool agent (P792) in Sprague-Dawley rats
    Mandry, D
    Pedersen, M
    Odille, F
    Robert, P
    Corot, C
    Felblinger, J
    Grenier, N
    Claudon, M
    INVESTIGATIVE RADIOLOGY, 2005, 40 (05) : 295 - 305
  • [7] In vitro relaxometric and luminescence characterization of P792 (Gadomelitol, Vistarem®), an efficient and rapid clearance blood pool MRI contrast agent
    Vander Elst, L
    Raynal, I
    Port, M
    Tisnès, P
    Muller, RN
    EUROPEAN JOURNAL OF INORGANIC CHEMISTRY, 2005, (06) : 1142 - 1148
  • [8] Improved evaluation of myocardial perfusion and viability with the magnetic resonance blood pool contrast agent P792 in a nonreperfused porcine infarction model
    Peukert, Daniel
    Kaufels, Nicola
    Laule, Michael
    Schnorr, Joerg
    Carme, Sabin
    Farr, Thomas
    Schoenenberger, Eva
    Taupitz, Matthias
    Hamm, Bernd
    Dewey, Marc
    INVESTIGATIVE RADIOLOGY, 2007, 42 (04) : 248 - 255
  • [9] Safety and pharmacokinetics of P792, a new blood-pool agent - Results of clinical testing in nonpatient volunteers
    Gaillard, S
    Kubiak, C
    Stolz, C
    Bonnemain, B
    Chassard, D
    INVESTIGATIVE RADIOLOGY, 2002, 37 (04) : 161 - 166
  • [10] Comparison of the tumoral biodistribution of P792, a rapid clearance blood pool agent and Gd-DOTA in a C6 glioma cerebral tumor model in rats
    Robert, P
    Santus, R
    Violas, X
    Rémy, C
    Corot, C
    ACADEMIC RADIOLOGY, 2002, 9 : S521 - S524