Evaluation of ogawa passive sampling devices as an alternative measurement method for the nitrogen dioxide annual standard in El Paso, Texas

被引:0
作者
Mark E. Sather
E. Terrence Slonecker
Johnson Mathew
Hunter Daughtrey
Dennis D. Williams
机构
[1] U.S. EPA Region 6,Air Quality Analysis Section
[2] National Exposure Research Laboratory,Landscape Ecology Branch
[3] U.S. EPA ORD,Houston Laboratory
[4] U.S. EPA Region 6,undefined
[5] Alion Science and Technology,undefined
来源
Environmental Monitoring and Assessment | 2007年 / 124卷
关键词
Nitrogen dioxide; Passive sampling; Ogawa; Annual standard; El Paso; Texas;
D O I
暂无
中图分类号
学科分类号
摘要
Nitrogen Dioxide (NO2) is a common urban air pollutant that results from the combustion of fossil fuels. It causes serious human health effects, is a precursor to the formation of ground level ozone, another serious air pollutant, and is one of the six criteria air pollutants established by the United States (U.S.) Clean Air Act (CAA). Ogawa Passive Sampling Devices (PSDs) for NO2 were collocated and operated at six NO2 Federal Reference Method (FRM) monitor locations in the El Paso, Texas area for the 2004 calendar year. Passive samples were taken at 2-week, 3-week, and 4-week intervals and compared against the continuously operating FRM monitors. Results showed that the collective NO2 annual arithmetic mean for all passive monitors was identical to the NO2 mean for all FRM monitors. Of the individual locations, three passive annual NO2 means were identical to their corresponding FRM means, and three passive annual NO2 means differed from their corresponding FRM means by only one part per billion (ppb). Linear correlation analysis between all readings of the individual NO2 PSDs and FRM values showed an average absolute difference of 1.2 ppb with an r2 of 0.95. Paired comparison between high and low concentration annual NO2 sites, seasonal considerations, and interlab quality control comparisons all showed excellent results. The ease of deployment, reliability, and the cost-savings that can be realized with NO2 PSDs could make them an attractive alternative to FRM monitors for screening purposes, and even possibly an equivalent method for annual NO2 monitoring. More tests of the Ogawa NO2 PSD are recommended for different ecosystem and climate regimes.
引用
收藏
页码:211 / 221
页数:10
相关论文
共 135 条
  • [1] Atkins D.H.F.(1995)Spatial and temporal variation of rural nitrogen dioxide concentrations across the United Kingdom Atmospheric Environment 29 223-239
  • [2] Lee D.S.(1998)Validation of passive diffusion samplers for SO2 and NO2 Atmospheric Environment 32 3587-3592
  • [3] Ayers G.P.(2001)Validation of nitrogen dioxide diffusion tube methodology in the UK Atmospheric Environment 35 289-296
  • [4] Keywood M.D.(2002)Distribution of ozone and other air pollutants in forests of the Carpathian Mountains in Central Europe Environmental Pollution 116 3-25
  • [5] Gillett R.(2002)Summer-time distribution of air pollutants in Sequoia National Park, California Environmental Pollution 118 187-203
  • [6] Manins P.C.(2002)Laboratory development and field evaluation of a new diffusive sampler to collect nitrogen oxides in the ambient air Anal. Bioanal. Chem. 373 901-907
  • [7] Malfroy H.(2005)Assessing spatial variability of ambient nitrogen dioxide in montreal, canada, with a land-use regression model JAWMA 55 1059-1063
  • [8] Bardsley T.(2003)Ambient nitrogen dioxide and distance from a major highway The Science of the Total Environment 312 43-46
  • [9] Bush T.(1999)Measurements of Nitrogen Dioxide on funen using diffusion tubes Atmospheric Environment 33 1177-1185
  • [10] Smith S.(2005)Characterization of a spatial gradient of nitrogen dioxide across a United States-Mexico border city during winter Science of the Total Environment 337 163-173