The balanced filter method for studying the hard X-ray spectrum of the plasma focus device

被引:0
|
作者
A. K. Dulatov
P. S. Krapiva
B. D. Lemeshko
Yu. V. Mikhailov
I. N. Moskalenko
I. A. Prokuratov
A. N. Selifanov
机构
[1] Dukhov All-Russia Research Institute of Automatics,
来源
Instruments and Experimental Techniques | 2015年 / 58卷
关键词
Energy Range; Spectral Sensitivity; Plasma Focus; Semiconductor Detector; Entrance Window;
D O I
暂无
中图分类号
学科分类号
摘要
A method for measuring hard X-ray spectra in an energy range of 10–88 keV using the difference filter method and semiconductor detectors is described. The method is applied for measuring the hard X-ray spectrum of a plasma-focus device with a stored energy of up to 3.7 kJ. The characteristic features of the spectrum of the plasma-focus devices are given. Based on this method, a spectrometer for measuring the hard X-ray spectrum of high-power pulse devices is designed at the All-Russia Research Institute of Automatics.
引用
收藏
页码:774 / 780
页数:6
相关论文
共 50 条
  • [21] Effect of anode shape on pinch structure and X-ray emission of plasma focus device
    Talukdar, N.
    Neog, N. K.
    Borthkur, T. K.
    RESULTS IN PHYSICS, 2013, 3 : 142 - 151
  • [22] Angular Distribution of Argon Ions and X-Ray Emissions in the Apf Plasma Focus Device
    Etaati, G. R.
    Amrollahi, R.
    Habibi, M.
    Baghdadi, R.
    JOURNAL OF FUSION ENERGY, 2011, 30 (02) : 121 - 125
  • [23] Characterization of soft X-ray radiation from plasma focus device with gas puff
    Kitaoka, H
    Yamamoto, T
    Hirano, K
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1998, 67 (02) : 481 - 486
  • [24] Preliminary study on X-ray source from Plasma Focus device for fast radiography
    Da Re, A
    Mezzetti, F
    Tartari, A
    Verri, G
    Rapezzi, L
    Gribkov, VA
    NUKLEONIKA, 2001, 46 : S123 - S125
  • [25] Study of X-ray emission from plasma focus device using vacuum photodiode
    Talukdar, N.
    Borthakur, T. K.
    Neog, N. K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 726 : 139 - 144
  • [26] Evolution of the Pinched Column During Hard X-ray and Neutron Emission in a Dense Plasma Focus
    P. Kubes
    M. Paduch
    M. J. Sadowski
    J. Cikhardt
    B. Cikhardtova
    D. Klir
    J. Kravarik
    V. Munzar
    K. Rezac
    E. Zielinska
    E. Skladnik-Sadowska
    A. Szymaszek
    K. Tomaszewski
    D. Zaloga
    Journal of Fusion Energy, 2019, 38 : 490 - 498
  • [27] Evolution of the Pinched Column During Hard X-ray and Neutron Emission in a Dense Plasma Focus
    Kubes, P.
    Paduch, M.
    Sadowski, M. J.
    Cikhardt, J.
    Cikhardtova, B.
    Klir, D.
    Kravarik, J.
    Munzar, V
    Rezac, K.
    Zielinska, E.
    Skladnik-Sadowska, E.
    Szymaszek, A.
    Tomaszewski, K.
    Zaloga, D.
    JOURNAL OF FUSION ENERGY, 2019, 38 (3-4) : 490 - 498
  • [28] Characterization of the Soft X-Ray Emission from the APF Plasma Focus Device Operated in Neon
    Baghdadi, R.
    Amrollahi, R.
    Etaati, G. R.
    Habibi, M.
    Roomi, A.
    JOURNAL OF FUSION ENERGY, 2011, 30 (02) : 137 - 143
  • [29] Characterization of the Soft X-Ray Emission from the APF Plasma Focus Device Operated in Neon
    R. Baghdadi
    R. Amrollahi
    G. R. Etaati
    M. Habibi
    A. Roomi
    Journal of Fusion Energy, 2011, 30 : 137 - 143
  • [30] Assessment of image quality in x-ray radiography imaging using a small plasma focus device
    Kanani, A.
    Shirani, B.
    Jabbari, I.
    Mokhtari, J.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 101 : 59 - 65