A multicenter clinical evaluation of Mycobacterium tuberculosis IgG/IgM antibody detection using the colloidal gold method

被引:0
作者
Y. Wang
B. Lu
J. Liu
T. Xiao
K. Wan
C. Guan
机构
[1] Central South University,Department of Physiology, Xiangya School of Medicine
[2] Chinese Center for Disease Control and Prevention,National Institute for Communicable Disease Control and Prevention
[3] State Key Laboratory for Infectious Disease Prevention and Control,undefined
[4] Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases,undefined
[5] China-Japan Friendship Hospital,undefined
来源
European Journal of Clinical Microbiology & Infectious Diseases | 2014年 / 33卷
关键词
Positive Predictive Value; Negative Predictive Value; Pool Sensitivity; Pool Specificity; Smear Staining;
D O I
暂无
中图分类号
学科分类号
摘要
A specific immunoassay method with the colloidal gold labeling technique has been developed more and more for tuberculosis (TB) diagnosis. The aim of this multicenter clinical evaluation was to evaluate the performance of a new serological diagnostic kit (the Trustline TB IgG/IgM Rapid Test kit) for the detection of Mycobacterium tuberculosis infection in China, with the Aupu TB Ab (IgG) Colloidal Gold Test kit being used as a control. A total of 1,009 specimens were collected from three TB hospitals, including 628 patients with TB, and 219 non-TB and 162 healthy patients as negative controls. According to the clinical diagnostic results, the sensitivities of the Trustline kit and the Aupu kit were 61.3 % and 53.7 %, respectively. Using the bacteriological test results as the “gold standard” to compare the results of the two kits, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and Youden index (YI) were 77.60 %, 79.8 %, 73.31 %, 81.50 %, and 0.574 by the Trustline kit, and 67.86 %, 88.9 %, 83.27 %, 77.40 %, and 0.568 by the Aupu kit, respectively. Further, the sensitivity of the Trustline kit and the Aupu kit for the smear staining and the bacterial culture being positive was 75.6 %, 76.6 % and 65.6 %, 66.5 %, and for the negative result, it was 53.8 %, 50.9 % and 47.5 %, 45.0 %, respectively. Additionally, 35 specimens were IgM-positive by the Trustline kit; of these, 30 (4.8 %) were from patients with TB and 5 (1.3 %) were from individuals without TB. The results showed that the experimental test had a much higher sensitivity than the other commercial test and exhibited a good detection rate for M. tuberculosis infection. Therefore, this kit can be used in the supplementary diagnosis and screening of TB.
引用
收藏
页码:1989 / 1994
页数:5
相关论文
共 47 条
  • [11] Winthrop KL(2007)A systematic review of rapid diagnostic tests for the detection of tuberculosis infection Health Technol Assess 11 1-7
  • [12] Nyendak M(2011)Commercial serological tests for the diagnosis of active pulmonary and extrapulmonary tuberculosis: an updated systematic review and meta-analysis PLoS Med 8 e1001062-22
  • [13] Calvet H(2012)Serological tests for the diagnosis of active tuberculosis: relevance for India Indian J Med Res 135 695-undefined
  • [14] Lawn SD(2002)Report on fourth national epidemiological sampling survey of tuberculosis Zhonghua Jie He He Hu Xi Za Zhi 25 3-undefined
  • [15] Bangani N(2010)Understanding latent tuberculosis: a moving target J Immunol 185 15-undefined
  • [16] Vogt M(undefined)undefined undefined undefined undefined-undefined
  • [17] Chan E(undefined)undefined undefined undefined undefined-undefined
  • [18] Reves R(undefined)undefined undefined undefined undefined-undefined
  • [19] Belisle JT(undefined)undefined undefined undefined undefined-undefined
  • [20] Brennan PJ(undefined)undefined undefined undefined undefined-undefined