Multipoint thermal-probe monitoring the radial gas distribution in blast furnaces with nonconical charging systems at OAO MMK

被引:0
作者
Parshakov V.M. [1 ]
Takhautdinov R.S. [2 ]
Bodyaev Y.A. [2 ]
Gibadullin M.F. [2 ]
Kanin L.S. [3 ]
Chevychelov A.V. [2 ]
Polinov A.A. [2 ]
Zakharov S.A. [4 ]
机构
[1] OOO AKOMM, Moscow
[2] OAO Magnitogorskii Metallurgicheskii Kombinat (MMK), Magnitogorsk
[3] OOO Spetsremstroi, Magnitogorsk
[4] OAO Magnitogorskii Gipromez, Magnitogorsk
关键词
Blast Furnace; Thermal Probe; Protective Housing; Furnace Axis; Batch Layer;
D O I
10.3103/S0967091209100106
中图分类号
学科分类号
摘要
Uncooled multipoint thermal probes are used to monitor the radial gas distribution in blast furnaces with nonconical charging systems at OAO MMK. In each furnace two probes are placed at fixed locations above the charge. Such probes have been installed in all four furnaces with nonconical charging systems at OAO MMK and are now in an operational state. © 2009 Allerton Press, Inc.
引用
收藏
页码:886 / 889
页数:3