Optimal Material Selection for Total Hip Implant: A Finite Element Case Study

被引:0
作者
Abdullah Tahir Şensoy
Murat Çolak
Irfan Kaymaz
Fehim Findik
机构
[1] Bayburt University,Technical Sciences Vocational School
[2] Bayburt University,Mechanical Engineering Department
[3] Erzurum Technical University,Engineering Faculty
[4] Sakarya Applied Sciences University,Technology Faculty
[5] Sakarya University,BIMAS
来源
Arabian Journal for Science and Engineering | 2019年 / 44卷
关键词
Hip prosthesis; Optimal material; Selection; CES; Finite element analysis; Implant;
D O I
暂无
中图分类号
学科分类号
摘要
The selection of most proper materials in engineering design is known as an important stage of the design process. In order to successfully complete this stage, it is necessary to have sufficient knowledge about the structure of materials, density, melting point, thermal expansion coefficient, tensile and yield strength, elongation, modulus of elasticity, hardness and many other properties. There are several selection systems that help the design engineer to choose most suitable material that meet the required properties. In the field of bioengineering, the selection of materials and the development of new materials for the clinical needs are increasingly important. In this study, the cases of optimal implant stabilization were investigated, material alternatives for hip prosthesis were evaluated, and optimal materials were determined. Using computerized tomography data with MIMICS software, virtual surgery was applied the hip bone and the implant was attached to bone. Boundary conditions and material properties have been defined, and finite element model has been created. FEA investigation of the mechanical behavior of the hip implant for various material alternatives determined by the CES software showed that the best material candidate is austenitic, annealed and biodurable stainless steel in terms of the micromotions at the implant–bone cement interface regarding osseointegration. This candidate showed 20.69% less strain value than the most commercially used hip implant material, Ti6Al4V. Therefore, the findings of this study suggest that the use of some specific stainless steel materials for implants may reduce the operation cost and increase the operation success for the total hip arthroplasty.
引用
收藏
页码:10293 / 10301
页数:8
相关论文
共 50 条
[21]   Finite element study on the effect of abutment length and material on implant bone interface against dynamic loading [J].
Mishra, Manish ;
Ozawa, Shogo ;
Masuda, Tatsuhiko ;
Yoshioka, Fumi ;
Tanaka, Yoshinobu .
JOURNAL OF ADVANCED PROSTHODONTICS, 2011, 3 (03) :140-144
[22]   Anchorage effects of a palatal osseointegrated implant with different fixation: A finite element study [J].
Chen, FS ;
Terada, K ;
Hanada, K ;
Saito, I .
ANGLE ORTHODONTIST, 2005, 75 (04) :593-601
[23]   Initial Stability of Subtrochanteric Oblique Osteotomy in Uncemented Total Hip Arthroplasty: A Preliminary Finite Element Study [J].
Li, Liangtao ;
Yu, Mingyang ;
Ma, Renshi ;
Zhu, Dong ;
Gu, Guishan .
MEDICAL SCIENCE MONITOR, 2015, 21 :1969-1975
[24]   Influence of bone material behavior assumption on finite element-predicted tibia-implant micromotions in total ankle replacement [J].
Johnson, Joshua E. ;
Anderson, Donald D. .
JOURNAL OF BIOMECHANICS, 2025, 189
[25]   Validation of a three dimensional finite element model of a femur with a customized hip implant. [J].
Couteau, B ;
Labey, L ;
Hobatho, MC ;
Vander Sloten, J ;
Arlaud, JY ;
Brignola, JC .
COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING - 2, 1998, :147-154
[26]   'Pre-launch' finite element analysis of a short-stem total hip arthroplasty system consisting of two implant types [J].
Lerch, Matthias ;
Windhagen, Henning ;
Kurtz, Agnes-Elisabeth ;
Budde, Stefan ;
Behrens, Bernd-Arno ;
Bouguecha, Anas ;
Almohallami, Amer .
CLINICAL BIOMECHANICS, 2019, 61 :31-37
[27]   A computational tool for the probabilistic finite element analysis of an uncemented total hip replacement considering variability in bone-implant version angle [J].
Dopico-Gonzalez, Carolina ;
New, Andrew M. ;
Browne, Martin .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2010, 13 (01) :1-9
[28]   Total Hip Arthroplasty in Hip Osteoarthritis with Subtrochanteric Localized Periosteal Thickening: Preoperative Planning Using Finite Element Analysis to Determine the Optimal Stem Length [J].
Shimasaki, Koshiro ;
Nishino, Tomofumi ;
Yoshizawa, Tomohiro ;
Watanabe, Ryunosuke ;
Hirose, Fumi ;
Yasunaga, Shota ;
Mishima, Hajime .
JOURNAL OF CLINICAL MEDICINE, 2024, 13 (19)
[29]   Finite element analysis of a novel design approach to resisting total hip dislocation [J].
Scifert, CF ;
Brown, TD ;
Lipman, JD .
CLINICAL BIOMECHANICS, 1999, 14 (10) :697-703
[30]   Finite Element Analysis (FEA) of the Different Cement Mixture for Total Hip Replacement [J].
Isa, Muhammad Izzuddin Md ;
Shuib, Solehuddin ;
Romli, Ahmad Zafir ;
Shokri, Amran Ahmed ;
Arrif, Iffa Mohd ;
Hamizan, Najwa Syakirah .
1ST NATIONAL BIOMEDICAL ENGINEERING CONFERENCE (NBEC 2021): ADVANCED TECHNOLOGY FOR MODERN HEALTHCARE, 2021, :13-18