Voltammetric and amperometric determination of hydrogen peroxide using a carbon-ceramic electrode modified with a nanohybrid composite made from single-walled carbon nanotubes and silver nanoparticles

被引:2
作者
Biuck Habibi
Mojtaba Jahanbakhshi
Mohammad Hossein Pournaghi-Azar
机构
[1] Azarbaijan University of Tarbiat Moallem,Electroanalytical Chemistry Laboratory, Department of Chemistry, Faculty of Sciences
来源
Microchimica Acta | 2012年 / 177卷
关键词
Nanohybrid composite; Silver nanoparticles; Single-walled carbon nanotubes; Carbon-ceramic electrode; Electrocatalysis; Hydrogen peroxide;
D O I
暂无
中图分类号
学科分类号
摘要
A nanohybrid composite material was prepared from single-walled carbon nanotubes and silver nanoparticles, and used to fabricate a modified carbon-ceramic electrode. The preparation of the composite is facile and efficient. The nanohybrid composite deposited on the carbon-ceramic electrode was characterized by X-ray diffraction and cyclic voltammetry. The new electrode displays favorable electrocatalytic ability towards hydrogen peroxide (H2O2) and can be used to electrocatalytically reduce this species. Under the optimum conditions, the current measured during hydrodynamic amperometry is linearly related to the concentration of H2O2 over the concentration range from 0.01 to 8 mM, with a detection limit of 2 × 10−7 M at a signal-to-noise ratio of 3 and sensitivity of 3.23 μA/mM. The electrode exhibits good reproducibility, long-term stability and negligible interference by dopamine, uric acid, and other important biological compounds. The electrode was successfully applied to the determination of H2O2 in honey samples, and the recovery was 101.2%.
引用
收藏
页码:185 / 193
页数:8
相关论文
共 279 条
  • [1] Bartlett PN(1998)An enzyme switch employing direct electrochemical communication between horseradish peroxidase and a poly(aniline) film Anal Chem 70 3685-undefined
  • [2] Birkin PR(1980)Spectrophotometric determination of hydrogen peroxide using potassium titanium(IV) oxalate Analyst 105 950-undefined
  • [3] Wang JH(1954)Accuracy of determination of hydrogen peroxide by cerate oxidimetry Anal Chem 26 320-undefined
  • [4] Palmisano F(1992)Oxo [5, 10, 15, 20-tetra (4-pyridyl) porphyrinato] titanium (IV): an ultra-high sensitivity spectrophotometric reagent for hydrogen peroxide Analyst 117 1781-undefined
  • [5] Benedetto GD(2001)Chemiluminescent flow sensor for H Anal Chim Acta 426 57-undefined
  • [6] Sellers RM(2011)O Microchim Acta 174 1-undefined
  • [7] Hurdis EC(2010) based on the decomposition of H Electrochem Commun 12 1746-undefined
  • [8] Romeyn H(2011)O Sensor Actuator B 151 377-undefined
  • [9] Matsubara C(2010) catalyzed by cobalt(II)-ethanolamine complex immobilized on resin Anal Chim Acta 674 20-undefined
  • [10] Kawamoto N(2009)Luminescent probes for detection and imaging of hydrogen peroxide Talanta 79 38-undefined