Effectiveness of carbon fiber-reinforced polymer as a triple-functional material for sustainable protection of reinforced concrete structures

被引:0
作者
Aifang Wei
Riyadh Al-Ameri
Mike Y. J. Tan
Yew-Chin Koay
Xiancun Hu
机构
[1] University of Canberra,School of Design and the Built Environment
[2] Deakin University,School of Engineering
[3] Major Transport Infrastructure Authority (MTIA),undefined
来源
Innovative Infrastructure Solutions | 2023年 / 8卷
关键词
CFRP; Triple function; Impressed current cathodic protection; Reinforced concrete; Harsh environment;
D O I
暂无
中图分类号
学科分类号
摘要
Corrosion of steel reinforcement in concrete is one of the major issues in reducing the service life and durability performance of reinforced concrete (RC) structures. Carbon fiber-reinforced polymer (CFRP) as a triple-functional material in the impressed current cathodic protection (ICCP) system has been innovatively investigated in this study. An experimental program comprising three kinds of current densities of 0 mA/m2, 20 mA/m2 and 100 mA/m2 is presented in RC beams. All specimens are under a simulated harsh environment of 3.5% NaCl solution at 50 °C, wet-dry cycle, and sustained loading. The constant current density of 20 mA/m2 was found to be sufficient for the ICCP system, a higher current density is not needed even without using the conductive epoxy. The experimental results confirmed that CFRP can not only be used as a strengthening material, but also play a coating layer and ICCP anode role for sustainable protection of RC structures against corrosion.
引用
收藏
相关论文
共 117 条
[1]  
Frhaan WKM(2021)CFRP for strengthening and repairing reinforced concrete: a review Innov Infrastruct Solut 6 1-13
[2]  
Abu Bakar BH(2000)Corrosion control of steel-reinforced concrete J Mater Eng Perform 9 585-588
[3]  
Hilal N(2022)Behavior of strengthened reinforced concrete beams under different CFRP strips arrangement Innov Infrastruct Solut 7 1-13
[4]  
Al-Hadithi AI(2016)Evaluation of external FRP-concrete bond in repaired concrete bridge girders and columns Innov Infrastruct Solut 1 1-8
[5]  
Chung DD(2011)Oxygen permeability of FRP-concrete repair systems J Compos Constr 16 277-285
[6]  
Boutlikht M(2018)Active and passive protection of steel reinforcement in concrete column using carbon fibre reinforced polymer against corrosion Electrochim Acta 278 124-136
[7]  
Lahbari N(2022)Polymer functional coatings modified by ZrP-based composites: preparation and applications on marine concrete J Appl Polym Sci 139 52384-2167
[8]  
Tabchouche S(2021)Impressed current cathodic protection of chloride-contaminated RC structures with cracking: a numerical study J Build Eng 44 102943-12
[9]  
Hebbache K(2015)Dual function carbon fibre fabric strengthening and impressed current cathodic protection (ICCP) anode for reinforced concrete structures Mater Struct 48 2157-402
[10]  
Pallempati H(2005)Use of Electrochemical techniques to assess performance of corrosion protection systems for reinforced concrete structures—a review J ASTM Int 3 1-349