Disruption of bioresorbable vascular scaffold struts due to loss of radial integrity: insights from optical coherence tomography

被引:0
|
作者
Ana Rita Ramalho
João Silva Marques
Guilherme Mariano Pêgo
机构
[1] Coimbra Hospital and Universitary Centre,Cardiology Department
来源
The International Journal of Cardiovascular Imaging | 2017年 / 33卷
关键词
Bioresorbable scaffold; Struts disruption; Optical coherence tomography;
D O I
暂无
中图分类号
学科分类号
摘要
Strut disruption of bioresorbable vascular scaffold is a known potential concern, although uncommon when adequate lesion preparation is achieved and nominal size of the scaffold is respected. It is usually difficult to detect with angiography and/or intravascular ultrasound. Three-dimensional reconstructions of optical coherence tomography facilitates understanding of complex luminal anatomy and configuration of stent struts, providing evaluation of stent integrity immediately after deployment and therefore optimization of the complex revascularization procedure. The present article reports a case where this image modality enabled successful use of a drug-eluting stent inside a bioresorbable vascular scaffold to restore the luminal integrity, jeopardized by struts disruption. This case highlights the need to better characterize coronary atherosclerotic disease complexity before considering bioresorbable vascular scaffold implantation. Optical coherence tomography imaging could be a useful tool for accurate selection of the most suitable lesions for bioresorbable stents and to guide the revascularization process, so that in the event of stent fracture it may be detected and managed in a timely fashion.
引用
收藏
页码:311 / 312
页数:1
相关论文
共 50 条
  • [1] Disruption of bioresorbable vascular scaffold struts due to loss of radial integrity: insights from optical coherence tomography
    Ramalho, Ana Rita
    Marques, Joao Silva
    Pego, Guilherme Mariano
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (03) : 311 - 312
  • [2] Recanalized Thrombus Treated With Bioresorbable Vascular Scaffold Insights From Optical Coherence Tomography
    Gomez-Monterrosas, Omar
    Regueiro, Ander
    Santos, Alejandro
    Otsuki, Shuji
    Scalone, Giancarla
    Fernandez-Rodriguez, Diego
    Sabate, Manel
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (12) : 1453 - 1455
  • [3] Use of Bioresorbable Vascular Scaffold in Acute Dissection Insights From Optical Coherence Tomography
    Basavarajaiah, Sandeep
    Naganuma, Toru
    Qadir, Mamoon
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (01) : E5 - E9
  • [4] Bioresorbable vascular scaffold implantation for treatment of recurrent in-stent restenosis: Insights from optical coherence tomography
    Camuglia, Anthony C.
    Lavi, Shahar
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 172 (01) : 238 - 239
  • [5] Persistent Bioresorbable Vascular Scaffold by Optical Coherence Tomography Imaging at 5 Years
    Moriyama, Noriaki
    Shishido, Koki
    Tobita, Kazuki
    Takada, Takuma
    Ochiai, Tomoki
    Tsukuda, Saori
    Yamanaka, Futoshi
    Sugitatsu, Kazuya
    Mizuno, Shingo
    Tanaka, Yutaka
    Murakami, Masato
    Matsumi, Junya
    Takahashi, Saeko
    Akasaka, Takeshi
    Saito, Shigeru
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (02) : E11 - E13
  • [6] Routine use of optical coherence tomography in bioresorbable vascular scaffold implantation: insights on technique optimization and long-term outcomes
    Abdelaziz, Hesham K.
    Abuomara, Hossamaldin Z.
    Ali, Montasir H.
    Eichhofer, Jonas
    Patel, Billal
    Saad, Marwan
    CORONARY ARTERY DISEASE, 2019, 30 (04) : 263 - 269
  • [7] Serial Analysis of the Malapposed and Uncovered Struts of the New Generation of Everolimus-Eluting Bioresorbable Scaffold With Optical Coherence Tomography
    Gomez-Lara, Josep
    Radu, Maria
    Brugaletta, Salvatore
    Farooq, Vasim
    Diletti, Roberto
    Onuma, Yoshinobu
    Windecker, Stephan
    Thuesen, Leif
    McClean, Dougal
    Koolen, Jacques
    Whitbourn, Robert
    Dudek, Dariusz
    Smits, Pieter C.
    Regar, Evelyn
    Veldhof, Susan
    Rapoza, Richard
    Ormiston, John A.
    Garcia-Garcia, Hector M.
    Serruys, Patrick W.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (09) : 992 - 1001
  • [8] Scaffold and Edge Vascular Response Following Implantation of Everolimus-Eluting Bioresorbable Vascular Scaffold A 3-Year Serial Optical Coherence Tomography Study
    Zhang, Yao-Jun
    Iqbal, Javaid
    Nakatani, Shimpei
    Bourantas, Christos V.
    Campos, Carlos M.
    Ishibashi, Yuki
    Cho, Yun-Kyeong
    Veldhof, Susan
    Wang, Jin
    Onuma, Yoshinobu
    Garcia-Garcia, Hector M.
    Dudek, Dariusz
    van Geuns, Robert-Jan
    Serruys, Patrick W.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (12) : 1361 - 1369
  • [9] Phenomenon of elongated struts: Is optical coherence tomography accurate enough to analyze scaffold area?
    Kharlamov, Alexander N.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (04) : 4280 - 4284
  • [10] Randomized Comparison of Optical Coherence Tomography Versus Angiography to Guide Bioresorbable Vascular Scaffold Implantation: The OPTICO BVS Study
    Ueki, Yasushi
    Yamaji, Kyohei
    Barbato, Emanuele
    Nef, Holger
    Brugaletta, Salvatore
    Alfonso, Fernando
    Hill, Jonathan
    Cook, Stephane
    Burzotta, Francesco
    Karagiannis, Alexios
    Windecker, Stephan
    Raber, Lorenz
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2020, 21 (10) : 1244 - 1250