Satisfied quantitative value can be acquired by short-time bone SPECT/CT using a whole-body cadmium–zinc–telluride gamma camera

被引:0
|
作者
Tomohiko Yamane
Masafumi Takahashi
Yohji Matsusaka
Kenji Fukushima
Akira Seto
Ichiei Kuji
Ichiro Matsunari
机构
[1] Saitama Medical University Hospital,Division of Nuclear Medicine, Department of Radiology
[2] Saitama Medical University International Medical Center,Department of Nuclear Medicine
[3] Saitama Medical University Hospital,Department of Central Radiological Technology
来源
Scientific Reports | / 11卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The aim of this study was to evaluate the quantitative values of short-time scan (STS) of metastatic lesions compared with a standard scan (SS) when acquired by whole-body bone SPECT/CT with cadmium–zinc–telluride (CZT) detectors. We retrospectively reviewed 13 patients with bone metastases from prostate cancer, who underwent SPECT/CT performed on whole-body CZT gamma cameras. STSs were obtained using 75, 50, 25, 10, and 5% of the list-mode data for SS, respectively. Regions of interest (ROIs) were set on the increased uptake areas diagnosed as metastases. Intraclass correlation coefficients (ICCs) of standardized uptake values (SUVs) for the ROIs were calculated between the SS and each STS, and ICC ≥ 0.8 was set as a perfect correlation. Moreover, the repeatability coefficient (RC) was calculated, and RC ≤ 20% was defined as acceptable. A total of 152 metastatic lesions were included in the analysis. The ICCs between the SS vs. 75%-STS, 50%-STS, 25%-STS, 10%-STS, and 5%-STS were 0.999, 0.997, 0.994, 0.983, and 0.955, respectively. The RCs of the SS vs. 75%-STS, 50%-STS, 25%-STS, 10%-STS, and 5%-STS were 7.9, 12.4, 19.8, 30.8, and 41.3%, respectively. When evaluating the quality of CZT bone SPECT/CT acquired by a standard protocol, 25%-STS may provide adequate quantitative values.
引用
收藏
相关论文
共 9 条
  • [1] Satisfied quantitative value can be acquired by short-time bone SPECT/CT using a whole-body cadmium-zinc-telluride gamma camera
    Yamane, Tomohiko
    Takahashi, Masafumi
    Matsusaka, Yohji
    Fukushima, Kenji
    Seto, Akira
    Kuji, Ichiei
    Matsunari, Ichiro
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [2] Diagnostic Ability of Quantitative Parameters of Whole-Body Bone SPECT/CT Using a Full-Ring 360° Cadmium-Zinc-Telluride Camera for Detecting Bone Metastasis in Patients with Prostate Cancer
    Yoo, Ik Dong
    Hong, Sun-pyo
    Lee, Sang Mi
    Yang, Hee Jo
    Kim, Ki Hong
    Kim, Si Hyun
    Lee, Jeong Won
    DIAGNOSTICS, 2024, 14 (23)
  • [3] Feasibility of Imaging Small Animals on a 360° Whole-Body Cadmium Zinc Telluride SPECT Camera: a Phantom Study
    Cedric Desmonts
    Nicolas Aide
    Henry Austins
    Cyril Jaudet
    Charline Lasnon
    Molecular Imaging and Biology, 2022, 24 : 1018 - 1027
  • [4] Feasibility of Imaging Small Animals on a 360° Whole-Body Cadmium Zinc Telluride SPECT Camera: a Phantom Study
    Desmonts, Cedric
    Aide, Nicolas
    Austins, Henry
    Jaudet, Cyril
    Lasnon, Charline
    MOLECULAR IMAGING AND BIOLOGY, 2022, 24 (06) : 1018 - 1027
  • [5] First comparison of performances between the new whole-body cadmium–zinc–telluride SPECT-CT camera and a dedicated cardiac CZT camera for myocardial perfusion imaging: Analysis of phantom and patients
    Maxime Morelle
    Dimitri Bellevre
    Claude Hossein-Foucher
    Alain Manrique
    Alban Bailliez
    Journal of Nuclear Cardiology, 2020, 27 : 1261 - 1269
  • [6] First comparison of performances between the new whole-body cadmium-zinc-telluride SPECT-CT camera and a dedicated cardiac CZT camera for myocardial perfusion imaging: Analysis of phantom and patients
    Morelle, Maxime
    Bellevre, Dimitri
    Hossein-Foucher, Claude
    Manrique, Alain
    Bailliez, Alban
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (04) : 1261 - 1269
  • [7] Prospective comparison of short-time whole-body bone SPECT and 18F-Fluoride PET in bone metastases detection from breast cancer
    Abikhzer, Gad
    Srour, Saher
    Chotipanich, Chanisa
    Fried, G.
    Drumea, K.
    Frenkel, Alex
    Israel, Ora
    Kagna, Olga
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [8] Evaluation of Collimators in a High-Resolution, Whole-Body SPECT/CT Device with a Dual-Head Cadmium-Zinc-Telluride Detector for 123I-FP-CIT SPECT
    Hiraki, Hitoshi
    Ito, Toshimune
    Onoguchi, Masahisa
    Tsuchikame, Hirotatsu
    Shishido, Masaaki
    Maeno, Takafumi
    Shibutani, Takayuki
    Sanada, Hiroki
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2023, 51 (03) : 227 - 234
  • [9] Compared visual analyses of whole-body planar bone scintigraphies obtained from conventional Anger camera and from retro-projections after CT-based corrections of a high-speed SPECT recording using a 360° CZT-camera
    Bahloul, A.
    Verger, A.
    Perrin, M.
    Claudin, M.
    Karcher, G.
    Marie, P.
    Imbert, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S124 - S124