A label-free electrochemical magnetic aptasensor based on exonuclease III–assisted signal amplification for determination of carcinoembryonic antigen

被引:0
|
作者
Xiaoyun Li
Chenyuan Weng
Jing Wang
Wei Yang
Qiaoyun Lu
Xiaoqiang Yan
Marwan Ahmad Sakran
Junli Hong
Wanying Zhu
Xuemin Zhou
机构
[1] Nanjing Medical University,School of Pharmacy
来源
Microchimica Acta | 2020年 / 187卷
关键词
Electrochemical aptasensor; Fe; O; @Au NPs; Exonuclease III; G-quadruplex/hemin complexes; Carcinoembryonic antigen;
D O I
暂无
中图分类号
学科分类号
摘要
A novel label-free and exonuclease III (Exo III)–assisted signal amplification electrochemical aptasensor was constructed for the determination of carcinoembryonic antigen (CEA) via magnetic field–induced self-assembly of magnetic biocomposites (Fe3O4@Au NPs-S1-S2-S3). The magnetic biocomposites were acquired by modifying double-stranded DNA (S1-S2-S3) on the surface of Fe3O4@Au nanoparticles (Fe3O4@Au NPs). Among them, Fe3O4@Au NPs were used as carriers for magnetic separation, thiolated single-stranded DNA (S1) provided signal sequence, CEA aptamer (S2) worked as a recognition element, and complementary strand (S3) was used to form double strands. In the presence of CEA, S2 bonded with CEA competitively; the exposed S1 could not be cleaved since Exo III was inactive against ssDNA. The G-quadruplex/hemin complexes finally formed with the existence of K+, and the high electrochemical signal of G-quadruplex/hemin complexes was recorded by differential pulse voltammetry (DPV) at − 0.6 V. Conversely, in the absence of CEA, dsDNA was cleaved from the 3′ blunt end by Exo III; the disappearance of G-rich sequence blocked the generation of the signal. This method exhibited good selectivity and sensitivity for the determination of CEA; the linear range was from 0.1 to 200 ng mL−1 and the limit of detection was 0.4 pg mL−1.
引用
收藏
相关论文
共 50 条
  • [1] A label-free electrochemical magnetic aptasensor based on exonuclease III-assisted signal amplification for determination of carcinoembryonic antigen
    Li, Xiaoyun
    Weng, Chenyuan
    Wang, Jing
    Yang, Wei
    Lu, Qiaoyun
    Yan, Xiaoqiang
    Sakran, Marwan Ahmad
    Hong, Junli
    Zhu, Wanying
    Zhou, Xuemin
    MICROCHIMICA ACTA, 2020, 187 (09)
  • [2] A sensitive electrochemical aptasensor for ATP detection based on exonuclease III-assisted signal amplification strategy
    Bao, Ting
    Shu, Huawei
    Wen, Wei
    Zhang, Xiuhua
    Wang, Shengfu
    ANALYTICA CHIMICA ACTA, 2015, 862 : 64 - 69
  • [3] Exonuclease III-assisted cascade signal amplification strategy for label-free and ultrasensitive electrochemical detection of nucleic acids
    Xiong, Erhu
    Yan, Xiaoxia
    Zhang, Xiaohua
    Liu, Yunqing
    Zhou, Jiawan
    Chen, Jinhua
    BIOSENSORS & BIOELECTRONICS, 2017, 87 : 732 - 736
  • [4] Label-free electrochemical biosensor based on Ng-PCL polymer signal amplification for the detection of carcinoembryonic antigen
    Wang, Xia
    Yuan, Xianxian
    Qin, Zhe
    Wang, Xinling
    Yang, Jing
    Yang, Huaixia
    MICROCHEMICAL JOURNAL, 2023, 195
  • [5] A label-free and lectin-based sandwich aptasensor for detection of carcinoembryonic antigen
    Wang, Qiong-Lin
    Cui, Hui-Fang
    Song, Xiaojie
    Fan, Shuang-Fei
    Chen, Li-Li
    Li, Meng-Meng
    Li, Zong-Yi
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 260 : 48 - 54
  • [6] An ultrasensitive fluorescent aptasensor for adenosine detection based on exonuclease III assisted signal amplification
    Hu, Peng
    Zhu, Chengzhou
    Jin, Lihua
    Dong, Shaojun
    BIOSENSORS & BIOELECTRONICS, 2012, 34 (01) : 83 - 87
  • [7] A Label-free Electrochemical Immunosensor for Carcinoembryonic Antigen Based on Graphene and Thionine
    Han, JingMan
    Ma, ZhanFang
    ADVANCED RESEARCH ON BIOCHEMICAL MATERIALS AND NANOTECHNOLOGY APPLICATION, 2013, 643 : 29 - 32
  • [8] An electrochemical aptasensor for highly sensitive detection of CEA based on exonuclease III and hybrid chain reaction dual signal amplification
    Niu, Cui
    Lin, Xiaojuan
    Jiang, Xin
    Guo, Fei
    Liu, Jianxiao
    Liu, Xiangqin
    Huang, Hongge
    Huang, Yu
    BIOELECTROCHEMISTRY, 2022, 143
  • [9] A Ratiometric Electrochemical Aptasensor with Exonuclease I-assisted Target Recycling Amplification for Highly Sensitive Detection of Carcinoembryonic Antigen
    Wang, Ping
    Ma, Huikai
    Xie, Yaoyao
    Li, Sanqiang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (11):
  • [10] Construction of electrochemical aptasensor of carcinoembryonic antigen based on toehold-aided DNA recycling signal amplification
    Zhang, Ren
    Liu, Li
    Mao, Dan
    Luo, Dan
    Cao, Fusheng
    Chen, Qinhua
    Chen, Jishun
    BIOELECTROCHEMISTRY, 2020, 133