Transmission Line Modeling and Algorithm Analysis Considering Parameter Asymmetry and Transient High-frequency Components

被引:0
作者
Shixun Mo
Zhipeng Lv
Kunlun Han
Rongji Yuan
Hao Yang
Kunping Jiang
Zhenshen Liang
机构
[1] Guangxi University,School of Electrical Engineering
来源
Journal of Electrical Engineering & Technology | 2021年 / 16卷
关键词
Transmission line; Phase coordinate approach; Time domain (frequency domain) analysis; Laplace transform; Harmonic; Vectorized NILT;
D O I
暂无
中图分类号
学科分类号
摘要
When the power system is disturbed or the operation mode is changed, the electromagnetic transient process will occur, which will lead to the high frequency transient component and affect the protection and control of the power system. Therefore, attention should be paid to the analysis of high-frequency transient components when modeling and analyzing the system model. In view of the fact that the symmetrical-component theory is not suitable for asymmetric transmission lines and the phasor method is not suitable for transient analysis and calculation, this paper uses the phase coordinate approach and Laplace transform to derive the node voltage equation of three-phase π type transmission lines in frequency domain, which can be used to calculate the transient response of transmission lines caused by the change of operation mode or disturbance. And vectorized NILT is used to calculate the time domain solution, which greatly improves the calculation speed. The calculated results are basically consistent with those of ATP-EMTP, and can fully reflect the transient characteristics. This method lays a foundation for analyzing the influence of high frequency transient components on power system and fault analysis considering transient process.
引用
收藏
页码:711 / 723
页数:12
相关论文
共 21 条
  • [1] Fortescue CL(1918)Method of symmetrical co-ordinates applied to the solution of polyphase networks Trans AIEE 37 1027-1140
  • [2] Laughton MA(1968)Analysis of unbalanced polyphase networks by the method of phase co-ordinates: part 1. System representation in phase frame of reference Proc IEE 115 163-172
  • [3] Laughton MA(1968)Analysis of unbalanced polyphase networks by the method of phase co-ordinates: part 2. Fault analysis Proc IEE 116 856-865
  • [4] Berman A(1998)Analysis of faulted power systems by phase coordinates IEEE Trans Power Deliv 13 587-595
  • [5] Wilsun Xu(1972)Analysis of power system faults by phase impedance matrix method: I—general fault analysis IEEE Trans Power Appar Syst PAS-91 592-600
  • [6] Pradipta KD(1972)Analysis of power system faults by phase impedance matrix method: II-simultaneous unbalances and transient analysis IEEE Trans Power Appar Syst PAS-91 601-610
  • [7] Pradipta KD(1974)General fault analysis using phase frame of reference Proc IEE 121 366-368
  • [8] Brameller A(1979)Generalised polyphase fault-analysis program calculation of cross-country fault Proc IEE 126 995-1001
  • [9] Pandey RS(1982)Exact calculation of simultaneous faults involving open conductors and line-to-ground short circuits on inherently unbalanced power systems IEEE Trans Power Appar Syst PAS-101 2738-2746
  • [10] Roy L(1997)A direct approach to short-circuit current calculation without using symmetrical components Int J Electr Power Energy Syst 19 293-298