Detection of meticillin-resistant Staphylococcus aureus and Panton-Valentine leukocidin directly from clinical samples and the development of a multiplex assay using real-time polymerase chain reaction

被引:0
|
作者
L. Renwick
A. Hardie
E. K. Girvan
M. Smith
G. Leadbetter
E. Claas
D. Morrison
A. P. Gibb
J. Dave
K. E. Templeton
机构
[1] Royal Infirmary of Edinburgh,Department of Microbiology
[2] Stobhill Hospital,Scottish MRSA Reference Laboratory, Department of Microbiology
[3] Leiden University Medical Center,Department of Medical Microbiology, Center of Infectious Diseases
来源
European Journal of Clinical Microbiology & Infectious Diseases | 2008年 / 27卷
关键词
Polymerase Chain Reaction; Multiplex Polymerase Chain Reaction; Nucleic Acid Extraction; Nasal Swab; SCCmec Type;
D O I
暂无
中图分类号
学科分类号
摘要
Meticillin-resistant Staphylococcus aureus (MRSA) is a major pathogen responsible for significant numbers of healthcare-associated infections and isolates containing Panton-Valentine leukocidin (PVL) that cause severe skin infections are emerging as a serious problem. The rapid detection of MRSA would be an invaluable tool in a diagnostic laboratory. The aim of this study is to develop real-time polymerase chain reaction (PCR) assays for the detection of MRSA and PVL directly from clinical samples, and then combining these assays. Individual assays for MRSA (SCCmec) and PVL (lukF and lukS) were optimised and evaluated with screening and wound swabs, respectively. MRSA- and PVL-positive isolates were detected by the assays with an analytical sensitivity of 100 cfu per reaction. No other bacterial species were amplified. Fifty of 402 (12.4%) nasal swabs were positive by culture and PCR. Four of the 402 (1.0%) swabs were PCR-positive/culture-negative. Three of the 402 (0.7%) swabs were PCR-negative/culture-positive. The sensitivity of the MRSA assay is 95% and the specificity is 99% using conventional culture as the gold standard. Five of 240 wound swabs (2.1%) were positive for PVL. Three of the PVL-positive swabs were meticillin-sensitive Staphylococcus aureus (MSSA) and two were MRSA. The MRSA assay is a powerful and sensitive diagnostic tool, giving rapid results and could allow more timely treatment and infection control decisions to be taken. It can also, when combined with the PVL assay, provide valuable epidemiological information.
引用
收藏
页码:791 / 796
页数:5
相关论文
共 19 条
  • [1] Multiplex Real-Time PCR for Detection of Staphylococcus aureus, mecA and Panton-Valentine Leukocidin (PVL) Genes from Selective Enrichments from Animals and Retail Meat
    Velasco, Valeria
    Sherwood, Julie S.
    Rojas-Garcia, Pedro P.
    Logue, Catherine M.
    PLOS ONE, 2014, 9 (05):
  • [2] Impact of preoperative screening for meticillin-resistant Staphylococcus aureus by real-time polymerase chain reaction in patients undergoing cardiac surgery
    Jog, S.
    Cunningham, R.
    Cooper, S.
    Wallis, M.
    Marchbank, A.
    Vasco-Knight, P.
    Jenks, P. J.
    JOURNAL OF HOSPITAL INFECTION, 2008, 69 (02) : 124 - 130
  • [3] Rapid detection of Panton–Valentine leukocidin-positive Staphylococcus aureus by real-time PCR targeting the lukS-PV gene
    U. Reischl
    M. J. Tuohy
    G. S. Hall
    G. W. Procop
    N. Lehn
    H. Linde
    European Journal of Clinical Microbiology & Infectious Diseases, 2007, 26 : 131 - 135
  • [4] Development of a TaqMan Real-Time Polymerase Chain Reaction Assay for Detection of Burkholderia mallei
    Pal, Vijai
    Saxena, Apoorva
    Singh, Sandeep
    Kumar, Subodh
    Goel, Ajay Kumar
    JOURNAL OF EQUINE VETERINARY SCIENCE, 2017, 58 : 58 - 63
  • [5] Detection of staphylococcal genes directly from cerebrospinal and peritoneal fluid samples using a multiplex polymerase chain reaction
    F. -J. Schmitz
    M. Steiert
    B. Hofmann
    A. C. Fluit
    J. Verhoef
    H. -P. Heinz
    M. E. Jones
    European Journal of Clinical Microbiology and Infectious Diseases, 1998, 17 : 272 - 274
  • [6] Detection of staphylococcal genes directly from cerebrospinal and peritoneal fluid samples using a multiplex polymerase chain reaction
    Schmitz, FJ
    Steiert, M
    Hofmann, B
    Fluit, AC
    Verhoef, J
    Heinz, HP
    Jones, ME
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1998, 17 (04) : 272 - 274
  • [7] Detection of the FCGR3a polymorphism using a real-time polymerase chain reaction assay
    Burchard, Paul R.
    Malhotra, Saurabh
    Kaur, Prabhjot
    Tsongalis, Gregory J.
    CANCER GENETICS, 2013, 206 (04) : 130 - 134
  • [8] Detection of methicillin-resistant Staphylococcus aureus (MRSA) from nasal samples by multiplex real-time PCR based on dual priming AT-rich primers
    M. K. Yadav
    S. K. Kwon
    H. J. Huh
    S-W. Chae
    J-J. Song
    Folia Microbiologica, 2012, 57 : 37 - 45
  • [9] Evaluation of a single-locus real-time polymerase chain reaction as a screening test for specific detection of methicillin-resistant Staphylococcus aureus in ICU patients
    K. Oberdorfer
    S. Pohl
    M. Frey
    K. Heeg
    C. Wendt
    European Journal of Clinical Microbiology and Infectious Diseases, 2006, 25 : 657 - 663
  • [10] A multiplex real-time polymerase chain reaction assay with two internal controls for the detection of Brucella species in tissues, blood, and feces from marine mammals
    Sidor, Inga F.
    Dunn, J. Lawrence
    Tsongalis, Gregory J.
    Carlson, Jolene
    Frasca, Salvatore, Jr.
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2013, 25 (01) : 72 - 81