Impact of seismic excitation characteristics on the efficiency of tuned liquid column dampers

被引:1
作者
Kavand A. [1 ]
Zahrai S.M. [2 ]
机构
[1] School of Civil Engineering, Sharif University of Technology, Tehran
[2] School of Civil Engineering, University of Tehran, Tehran
关键词
Frequency content; Passive control; Seismic excitation characteristics; Seismic performance; Subsoil conditions; Tuned liquid column dampers;
D O I
10.1007/s11803-006-0639-5
中图分类号
学科分类号
摘要
Various types of passive control systems have been used to suppress the seismic response of structures in recent years. Among these systems, Tuned Liquid Column Dampers (TLCDs) dissipate the input earthquake energy by combining the effects of the movement of the liquid mass in the container, the restoring force on the liquid due to the gravity loads and the damping due to the liquid movement through orifices. In this study, the effects of seismic excitation characteristics such as frequency content and soil condition on the seismic performance of TLCDs are investigated using nonlinear time-history analyses. In this regard, among the past earthquake ground motion records of Iran, 16 records with different parameters were selected. In the structural model developed, the attached TLCD is simulated as a Tuned Mass Damper (TMD) having the same vibration period and damping ratio as the original TLCD. The numerical results show that the seismic excitation characteristics have a substantial role on the displacement reduction capability of TLCDs and they should be considered accordingly in the design of TLCDs.
引用
收藏
页码:235 / 243
页数:8
相关论文
共 13 条
  • [1] Abe M., Kimura S., Fujino Y., Control Laws for Semiactive Tuned Liquid Column Damper with Variable Orifice Opening, 2nd Int. Workshop on Structural Control, (1996)
  • [2] Earthquake Records of Iran, (2003)
  • [3] El Damatty A., Studies on the Application of Tuned Liquid Dampers (TLD) to Up-grade the Seismic Resistance of Structures, ICLR Research, Paper Series -No, 17, (2002)
  • [4] Haroun M.A., Piers J.A., Active Orifice Control in Hybrid Liquid Column Dampers, 1st world Conference on Structural Control, 1, (1994)
  • [5] Ibrahimbegovic A., Wilson E.L., Simple Numerical Algorithms for the Mode Superposition Analysis of Linear Structural Systems with Nonproportional Damping, Computers and Structures, 33, 2, pp. 523-531, (1989)
  • [6] Kareem A., The Next Generation of Tuned Liquid Dampers, 1st World Conference on Structural Control, (1994)
  • [7] Kwok K.C.S., Xu Y.L., Samali B., Control of Wind-induced Vibrations of Tall Structures by Optimized Tuned Liquid Column Dampers, Computational Mechanics, pp. 249-254, (1991)
  • [8] Mir Ahsani V., Seismic Design Response Spectra for Iran, Research Report, (2001)
  • [9] Rathje E.M., Abrahamson N.A., Bray J.D., Simplified Frequency Content Estimates of Earthquake Ground Motions, Journal of Geotechnical and Geoenvironmental Engineering, 124, 2, pp. 150-159, (1998)
  • [10] Sadek F., Moheraz B., Lew H.S., Single and Multiple Tuned Liquid Column Dampers for Seismic Applications, Earthquake Eng. and Structural Dynamics, 27, pp. 439-463, (1998)