Clinical usefulness of temporal subtraction method in screening digital chest radiography with a mobile computed radiography system

被引:5
|
作者
Sasaki Y. [1 ]
Abe K. [2 ]
Tabei M. [3 ]
Katsuragawa S. [4 ]
Kurosaki A. [5 ]
Matsuoka S. [1 ]
机构
[1] Department of Radiology, Iwate Prefectural Central Hospital, Morioka 020-0066
[2] Department of Radiology, School of Medicine, Nihon University, Itabashi-Ku, Tokyo 173-8610
[3] Medical Systems Business Division, FUJIFILM Medical, Minato-Ku, Tokyo 106-8620
[4] Department of Medical Physics, School of Health Sciences, Kumamoto University, Kumamoto 862-0976
[5] Department of Radiology, Toranomon Hospital, Minato-Ku, Tokyo 105-8470
关键词
Computed radiography; Digital radiography; Lung cancer screening; ROC analysis; Temporal subtraction image;
D O I
10.1007/s12194-010-0109-7
中图分类号
学科分类号
摘要
The temporal subtraction image which is obtained by subtraction of a previous image from a current image of the same patient can enhance interval changes. In this study, we applied the temporal subtraction method for lung cancer screening and evaluated the clinical usefulness by comparing the review time and the detection accuracy of lung cancers without and with subtraction images. Since 1996, we have been performing screening chest radiography for a mass survey of lung cancers in the Iwate Prefecture, Japan, by using a van equipped with a computed radiography system and a digital archive system. During the 12 years from 1997 to 2008, a total of 186,340 examinations were performed, and 121,526 (65.2%) temporal subtraction images were provided in the lung cancer screening. Twenty-four abnormal cases with lung cancer and 270 normal cases were selected from the lung cancer screening. Five radiologists participated in an observer performance study and interpreted previous and current chest radiographs without and with temporal subtraction images. In addition, radiologists interpreted previous and current images with a double-reading method. The average ROC curves demonstrated a significant improvement in the detection accuracy of lung cancers with the temporal subtraction images compared with that without the temporal subtraction images, and that with the double-reading method. Therefore, we believe strongly that the temporal subtraction method is clinically useful for radiologists in the detection of lung cancers in mass surveys. © 2010 Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:84 / 90
页数:6
相关论文
共 50 条
  • [31] Assessment of Clinical Image Quality in Feline Chest Radiography with a Needle-Image Plate (NIP) Storage Phosphor System - An Approach to the Evaluation of Image Quality in Neonatal Radiography
    Ludewig, E.
    Hirsch, W.
    Bosch, B.
    Gaebler, K.
    Sorge, I.
    Succow, D.
    Werrmann, A.
    Gosch, D.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (02): : 122 - 132
  • [32] System considerations in CCD-based x-ray imaging for digital chest radiography and digital mammography
    Hejazi, S
    Trauernicht, DP
    MEDICAL PHYSICS, 1997, 24 (02) : 287 - 297
  • [33] Development of a Mini-Mobile Digital Radiography System by Using Wireless Smart Devices
    Jeong, Chang-Won
    Joo, Su-Chong
    Ryu, Jong-Hyun
    Lee, Jinseok
    Kim, Kyong-Woo
    Yoon, Kwon-Ha
    JOURNAL OF DIGITAL IMAGING, 2014, 27 (04) : 443 - 448
  • [34] Development of a Mini-Mobile Digital Radiography System by Using Wireless Smart Devices
    Chang-Won Jeong
    Su-Chong Joo
    Jong-Hyun Ryu
    Jinseok Lee
    Kyong-Woo Kim
    Kwon-Ha Yoon
    Journal of Digital Imaging, 2014, 27 : 443 - 448
  • [35] Screening Mammography Efficacy: A Comparison Between Screen-Film, Computed Radiography and Digital Mammography in Taiwan
    Elbakkoush, Abdallah Ahmed
    Atique, Suleman
    Chiang, I-Jen
    MEDINFO 2015: EHEALTH-ENABLED HEALTH, 2015, 216 : 914 - 914
  • [36] Initial clinical performance of a large-field KCD digital radiography system
    DiBianca, F
    Rodriguez, C
    Devidas, S
    Emerson, D
    Gaber, MW
    Giakos, G
    Gold, R
    Jordan, L
    Kaufman, R
    Kollipara, S
    Laughter, J
    Mahmud, A
    Nagarajan, S
    Peng, Q
    Price, PJ
    Sebes, J
    Zeman, H
    Zhu, ZP
    PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 826 - 836
  • [37] CLINICAL-APPLICATION OF SINGLE DUAL-ENERGY SUBTRACTION TECHNIQUE WITH DIGITAL STORAGE-PHOSPHOR RADIOGRAPHY
    KAMIMURA, R
    TAKASHIMA, T
    JOURNAL OF DIGITAL IMAGING, 1995, 8 (01) : 21 - 24
  • [38] Contrast-detail evaluation and dose assessment of eight digital chest radiography systems in clinical practice
    Veldkamp, WJH
    Kroft, LJM
    Boot, MV
    Mertens, BJA
    Geleijns, J
    EUROPEAN RADIOLOGY, 2006, 16 (02) : 333 - 341
  • [39] Contrast-detail evaluation and dose assessment of eight digital chest radiography systems in clinical practice
    Wouter J. H. Veldkamp
    Lucia J. M. Kroft
    Mireille V. Boot
    Bart J. A. Mertens
    Jacob Geleijns
    European Radiology, 2006, 16 : 333 - 341
  • [40] Application of off-line image processing for optimization in chest computed radiography using a low cost system
    Muhogora, Wilbroad E.
    Msaki, Peter
    Padovani, Renato
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (02): : 322 - 333